SourceMed · Shelf #10020 in the ask interface
Ethanol locks for preventing catheter-related bloodstream infection: pooled randomised evidence shows a relative risk of 0.66 (10 trials, 2,760 patients) — with more nausea, dizziness, flushing and altered taste
Shelf #10020 · Critical care & sepsis
LIKELY (benefit)
Stamped: 2026-11-28.
Evidence published: 2018–2019.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients with central venous catheters, does ethanol lock prophylaxis reduce catheter-related bloodstream infection compared with heparin or saline locks?
Balance of the evidence
LIKELY (benefit) — Composition: two systematic reviews and meta-analyses of randomised trials — 10 trials in 2,760 patients (Zhang 2018) and 9 trials in 2,451 patients (Zhang 2019); the pools overlap and are not added. The larger pool found catheter-related bloodstream infection relative risk 0.66 (95% CI 0.51 to 0.86) — a 34% relative reduction; absolute infection rates by arm are not printed in the record, so no absolute figure is stated here. The second pool, against heparin alone, found odds ratio 0.53 (95% CI 0.34 to 0.82; P = 0.004), but its comparison against 0.9% saline locks was not statistically significant. Ethanol did not increase thrombosis (relative risk 1.05) or mortality (0.99), but increased nausea (relative risk 1.54), dizziness (4.21), flushing (3.27) and altered taste (2.61). This shelf covers prevention across catheter populations generally; dialysis-specific citrate and taurolidine lock questions live on their own shelves. LIKELY (benefit): two concordant meta-analyses of randomised trials show fewer catheter-related bloodstream infections, with the saline-comparator limb the weak point.
MeSH: Anti-Infective Agents, Local · Anticoagulants · Catheter-Related Infections · Catheterization, Central Venous · Catheters · Central Venous Catheters · Ethanol · Heparin · Humans · Randomized Controlled Trials as Topic · Sterilization · Thrombosis
Cards (3)
Card 1 — Meta-analysis of 10 RCTs (2,760 patients): CRBI relative risk 0.66 with ethanol locks (Zhang 2018)
Study: Systematic review and meta-analysis of randomised trials (10 trials, N = 2,760)
Population: 10 randomised trials in 2,760 patients with central venous catheters, comparing ethanol lock prophylaxis with control locks; subgroup analyses by study quality, lock duration, disease type and infection definition.
Summary: Meta-analysis of 10 RCTs (2,760 patients): CRBI relative risk 0.66 with ethanol locks (Zhang 2018)
Result: Ethanol locks significantly reduced catheter-related bloodstream infection overall (relative risk 0.66, 95% CI 0.51 to 0.86) — a 34% relative reduction. The effect held in high-quality (0.66, 0.47 to 0.94) and low-quality (0.66, 0.46 to 0.95) studies and under a strict infection definition (0.61, 0.42 to 0.89); it was strongest in haematological disease (0.50, 0.31 to 0.80) and with 2-hour locks (0.49, 0.33 to 0.73). Thrombosis (relative risk 1.05, 0.51 to 2.18) and mortality (0.99, 0.90 to 1.08) were unchanged; nausea (1.54), dizziness (4.21), flushing (3.27) and altered taste (2.61) were increased.
Watch out: Ethanol concentration and dwell time varied across trials, and most evidence comes from haematology and intestinal-failure populations with long-term catheters — transport to short-term ICU catheters is assumed, not shown.
Source: Zhang P et al.. Ethanol locks for the prevention of catheter-related bloodstream infection: a meta-analysis of randomized control trials. BMC anesthesiology. 2018. PMID: 30041610. Registry ID: not stated in the record. MeSH: Anti-Infective Agents, Local · Catheters · Ethanol · Humans · Randomized Controlled Trials as Topic · Sterilization
Card 2 — Second meta-analysis (9 RCTs, 2,451 patients): odds ratio 0.53 versus heparin — but not significant versus saline (Zhang 2019)
Study: Systematic review and meta-analysis of randomised trials (9 trials, N = 2,451)
Population: 9 randomised trials in 2,451 patients with central venous catheters, assessing ethanol lock prophylaxis against control locks including heparin and 0.9% sodium chloride. This pool overlaps the 10-trial pool above and is not additional patients.
Summary: Second meta-analysis (9 RCTs, 2,451 patients): odds ratio 0.53 versus heparin — but not significant versus saline (Zhang 2019)
Result: Ethanol lock prophylaxis reduced catheter-related bloodstream infection compared with heparin alone (odds ratio 0.53, 95% CI 0.34 to 0.82; P = 0.004). Against 0.9% saline locks the effect was in the same direction but not statistically significant. Exit-site infection, catheter dysfunction, catheter removal, thrombosis and mortality did not differ significantly. The authors call for attention to a uniform ethanol lock procedure and to toxic effects of long-term exposure.
Watch out: The saline comparison is the honest comparator for a lock whose control is inert — and there the pooled result is not significant, which is why this shelf's claim is prevention versus standard heparin-based practice, stated with that limb visible.
Source: Zhang J et al.. Ethanol locks for the prevention of catheter-related infection in patients with central venous catheter: A systematic review and meta-analysis of randomized controlled trials. PloS one. 2019. PMID: 31513652. Registry ID: not stated in the record. MeSH: Anticoagulants · Catheter-Related Infections · Catheterization, Central Venous · Central Venous Catheters · Ethanol · Heparin · Humans · Thrombosis
Card 3 — Synthesis: two overlapping pools, one direction — fewer bloodstream infections, more minor systemic symptoms
Study: Synthesis
Population: Documented evidence base: 2,760 patients in the larger randomised pool (the 2,451-patient pool overlaps it and is not added).
Summary: Synthesis: two overlapping pools, one direction — fewer bloodstream infections, more minor systemic symptoms
Result: Pooled randomised evidence consistently favours ethanol locks for preventing catheter-related bloodstream infection, with no thrombosis or mortality penalty and a reproducible set of transient symptoms. LIKELY (benefit).
Watch out: Long-term catheter integrity with repeated ethanol exposure and the optimal concentration and dwell time remain unsettled; neither meta-analysis could standardise the procedure across trials.
Source: Synthesis of Zhang P et al.. BMC anesthesiology. 2018 (PMID: 30041610) ; Zhang J et al.. PloS one. 2019 (PMID: 31513652).