Spirometry substitutes under test: the recommended oscillometry bronchodilator thresholds caught almost no asthma cases in children (sensitivity near zero in two studies, specificity above 85%), plethysmographic conductance during methacholine challenge traded sensitivity 97% against specificity 67%, and peak-flow falls misread obstruction in about 40% of challenges

Shelf #10042 · Lungs, breathing & sleep

MEASUREMENT ACCURACY — PARTIAL

Stamped: 2026-11-28.

Evidence published: 2024–2026.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

How accurately do non-spirometric lung-function measures — oscillometry bronchodilator response in children, body-plethysmographic specific airway conductance during methacholine challenge, and peak expiratory flow change during bronchoconstriction — identify asthma or airway hyperreactivity against spirometric and follow-up reference standards?

Balance of the evidence

MEASUREMENT ACCURACY — PARTIAL — Composition: a systematic review of oscillometry for asthma diagnosis in children and young people (11 studies: 992 participants against bronchodilator-response reference standards and 531 against methacholine-challenge standards; Seneviratne 2026), a 109-patient plethysmography-versus-challenge study in suspected cough-variant asthma with 1-year treatment-response follow-up (Karamarkovic Lazarusic 2024; the record carries no MeSH list), and an 878-patient retrospective comparison of peak-flow and FEV1 falls during methacholine challenge (Csonka 2024). The documented base is 2,510 people, above the 30 minimum. Sensitivity and specificity are labelled in words at first occurrence: at the currently recommended European Respiratory Society oscillometry bronchodilator thresholds, two studies found sensitivity of zero (no cases detected) with specificity above 85%; data-derived thresholds performed only moderately — a 17.0% fall in resistance gave sensitivity and specificity both of 71.6% (Seneviratne 2026). Plethysmographic conductance was the mirror image: sensitivity 97% but specificity 67% at the PC40 cut-off, against sensitivity 64% / specificity 88% for the spirometric PC20 criterion in the same patients (Karamarkovic Lazarusic 2024). Peak-flow change tracked FEV1 change only loosely (areas under the curve 0.844–0.893; obstruction false in about 40% of cases) (Csonka 2024). The oscillometry grade rests on a single synthesis whose studies could not be meta-analysed — flagged here and on its card. Boundary: oscillometry reference equations in healthy adults and FeNO diagnostic accuracy are homed elsewhere in the library. MEASUREMENT ACCURACY — PARTIAL: each substitute trades sensitivity against specificity at a different point, none reproduces spirometry, and the endorsed oscillometry thresholds are set where sensitivity collapses.

MeSH: Humans · Oscillometry · Asthma · Child · Spirometry · Predictive Value of Tests · Bronchial Provocation Tests · Child, Preschool · Reproducibility of Results · Sensitivity and Specificity · Adolescent · Lung · Forced Expiratory Volume · Retrospective Studies · Male · Female · Bronchoconstriction · Adult · Methacholine Chloride · Peak Expiratory Flow Rate · Middle Aged · Bronchoconstrictor Agents · ROC Curve · Young Adult · Area Under Curve · Time Factors

Cards (3)

Card 1 — Oscillometry in children: endorsed bronchodilator thresholds gave sensitivity near zero in two studies; best data-derived thresholds reached only about 72% / 72% (Seneviratne 2026)

Study: Systematic review of 11 accuracy studies (N = 1,523 across reference standards)

Population: Systematic review of 11 studies comparing oscillometry with spirometry in children and young people under investigation for asthma: 6 studies (992 participants) using bronchodilator response as reference standard and 5 studies (531 participants) using methacholine challenge. Meta-analysis was not possible because of heterogeneity.

Summary: Oscillometry in children: endorsed bronchodilator thresholds gave sensitivity near zero in two studies; best data-derived thresholds reached only about 72% / 72% (Seneviratne 2026)

Result: In two studies using the current European Respiratory Society bronchodilator thresholds (a fall in resistance at 5 Hz above 40%, and related criteria), sensitivity was zero with specificity above 85%. In weighted regression analyses, a 17.0% decrease in resistance at 5–6 Hz had sensitivity and specificity of 71.6%; a 20.2% increase in reactance at 5 Hz gave 68.6% for both; and a 27.7% increase in resistance identified methacholine positivity with sensitivity and specificity of 73.6%. The authors concluded the recommended thresholds have low sensitivity and proposed thresholds require prospective validation.

Watch out: Single-synthesis limb of this pack: one review, no meta-analysis possible, and its headline finding is about thresholds set by a standards document — the failure is in the cut-offs at least as much as in the measurement.

Source: Seneviratne SY, Law-Gleen S, Broomfield J, Divall P et al.. Oscillometry for the diagnosis of asthma in children: a systematic review. European respiratory review : an official journal of the European Respiratory Society. 2026. PMID: 42055592. Registry ID: not stated in the record. MeSH: Humans · Oscillometry · Asthma · Child · Spirometry · Predictive Value of Tests · Bronchial Provocation Tests · Child, Preschool · Reproducibility of Results · Sensitivity and Specificity · Adolescent · Lung

Card 2 — Plethysmographic conductance in suspected cough-variant asthma: sensitivity 97% / specificity 67% at PC40, versus spirometric PC20 at 64% / 88% (Karamarkovic Lazarusic 2024)

Study: Prospective accuracy study with 1-year follow-up (N = 109)

Population: 109 patients with suspected cough-variant asthma who underwent bronchodilation testing, methacholine challenge with spirometry, and body plethysmography; airway hyperreactivity was found in 83.5% (91 of 109) by any method, and asthma was confirmed in 76 patients after 1 year of follow-up on treatment response. The record carries no MeSH list.

Summary: Plethysmographic conductance in suspected cough-variant asthma: sensitivity 97% / specificity 67% at PC40, versus spirometric PC20 at 64% / 88% (Karamarkovic Lazarusic 2024)

Result: Sensitivity and specificity against the follow-up diagnosis were: bronchodilation test 25% and 94%; spirometric PC20FEV1 64% and 88%; plethysmographic PC40sGaw 97% and 67%. At stricter conductance cut-offs the balance shifted — PC45sGaw sensitivity 88% / specificity 82%, and PC50sGaw sensitivity 63% / specificity 91% — with the best sensitivity-to-specificity ratio at PC45.

Watch out: The reference standard includes response to the treatment the test triggered, in a single specialist clinic with an 83.5% hyperreactivity rate: accuracy figures from this spectrum will not transfer to unselected cough clinics.

Source: Karamarkovic Lazarusic N, Popovic-Grle S, Tolic E, Stajduhar A et al.. The Value of Body Plethysmography (sGaw) in the Assessment of Airway Hyperreactivity in Cough Variant Asthma. Journal of clinical medicine. 2024. PMID: 39797163. Registry ID: not stated in the record. MeSH: not stated in the record (no MeSH list)

Card 3 — Peak-flow falls under-read FEV1 falls during challenge: areas under the curve 0.844–0.893, obstruction false in about 40% of cases (Csonka 2024)

Study: Retrospective paired-measurement study (N = 878)

Population: 878 patients who completed a methacholine challenge test, studied retrospectively; relative changes in peak expiratory flow and in FEV1 during induced bronchoconstriction were compared by regression, Bland–Altman and receiver-operating analyses.

Summary: Peak-flow falls under-read FEV1 falls during challenge: areas under the curve 0.844–0.893, obstruction false in about 40% of cases (Csonka 2024)

Result: The relative change in peak expiratory flow was on average less than the relative change in FEV1. Areas under the curve for a peak-flow decrease predicting a 10% and a 15% FEV1 decrease were 0.844 and 0.893 respectively. Agreement between the changes varied from fair to moderate, and airway obstruction detected by change in peak flow was false in about 40% of cases when compared with FEV1.

Watch out: A within-challenge comparison, not a diagnostic study in suspected asthma: it shows peak flow cannot be swapped for FEV1 mid-test, which is a narrower claim than peak flow's value in home monitoring.

Source: Csonka LL, Tikkakoski A, Vuotari L, Karjalainen J et al.. Relation of changes in peak expiratory flow (PEF) and forced expiratory volume in 1 s (FEV1) during bronchoconstriction. Clinical physiology and functional imaging. 2024. PMID: 38923340. Registry ID: not stated in the record. MeSH: Humans · Forced Expiratory Volume · Retrospective Studies · Male · Female · Bronchoconstriction · Bronchial Provocation Tests · Predictive Value of Tests · Adult · Asthma · Methacholine Chloride · Lung · Spirometry · Peak Expiratory Flow Rate · Reproducibility of Results · Middle Aged · Bronchoconstrictor Agents · ROC Curve · Young Adult · Area Under Curve · Time Factors · Adolescent