SourceMed · Shelf #10044 in the ask interface
EBUS-TBNA for mediastinal staging of lung cancer: pooled sensitivity 0.93 / specificity 1.00 in imaging-selected patients, but sensitivity only 49% for occult metastases in the radiologically normal mediastinum
Shelf #10044 · Lungs, breathing & sleep
MEASUREMENT ACCURACY — PARTIAL
Stamped: 2026-11-28.
Evidence published: 1990–2019.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients with known or suspected lung cancer, how accurately does endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) detect metastatic mediastinal lymph nodes against surgical staging — in patients selected by CT or PET, and in patients whose mediastinum looks normal on imaging?
Balance of the evidence
MEASUREMENT ACCURACY — PARTIAL — Composition: two overlapping meta-analyses of EBUS-TBNA for mediastinal staging in mostly imaging-selected patients (Gu 2009: 11 studies, 1,299 patients; Adams 2009: 10 studies, participant total not stated in the record) and one meta-analysis restricted to the radiologically normal mediastinum in clinical N0/N1 disease (Leong 2019: 9 studies, 1,146 patients). The syntheses' primary-study pools overlap, so totals are never added; the documented base is 2,445 patients across the two syntheses that state one, plus the Adams pool whose size its record does not state. Sensitivity and specificity are labelled in words at first occurrence: pooled sensitivity 0.93 / specificity 1.00 overall (Gu 2009), with sensitivity 0.94 in patients selected by positive CT or PET against 0.76 in unselected patients; Adams 2009 found pooled sensitivity 0.88 / specificity 1.00. The picture reverses when nodes look normal on imaging: pooled sensitivity was only 49% (95% CI 41% to 57%) at specificity 100% for unsuspected N2/N3 disease, with a mean negative predictive value of 91% and 14 patients needing testing to detect one occult case (Leong 2019). Boundary: this pack is about the accuracy of the sampling test; treatment questions for staged lung cancer, and the reference values for the imaging tests themselves, are homed elsewhere. MEASUREMENT ACCURACY — PARTIAL: EBUS-TBNA confirms involved nodes almost without false positives and is highly sensitive where imaging already points, but it misses about half of occult metastases in a normal-looking mediastinum, so a negative result there cannot end the staging question.
MeSH: Area Under Curve · Biopsy, Needle · Endosonography · Humans · Lung Neoplasms · Lymph Nodes · Lymphatic Metastasis · Middle Aged · Neoplasm Staging · Sensitivity and Specificity · Ultrasonography, Interventional · Bronchoscopy · Epidemiologic Methods · Mediastinum · Carcinoma, Non-Small-Cell Lung · Endoscopic Ultrasound-Guided Fine Needle Aspiration · Predictive Value of Tests · Preoperative Period
Cards (3)
Card 1 — Staging meta-analysis (1,299 patients): pooled sensitivity 0.93 / specificity 1.00 — but sensitivity fell to 0.76 without CT/PET selection (Gu 2009)
Study: Systematic review and meta-analysis of 11 accuracy studies (N = 1,299)
Population: Systematic review and meta-analysis of 11 studies (1,299 patients) evaluating EBUS-TBNA accuracy for detecting metastatic mediastinal lymph nodes in lung cancer, against surgical confirmation; no publication bias was found.
Summary: Staging meta-analysis (1,299 patients): pooled sensitivity 0.93 / specificity 1.00 — but sensitivity fell to 0.76 without CT/PET selection (Gu 2009)
Result: Pooled sensitivity was 0.93 (95% CI 0.91 to 0.94) and pooled specificity 1.00 (95% CI 0.99 to 1.00). In the subgroup selected on the basis of positive CT or PET results, pooled sensitivity was 0.94 (95% CI 0.93 to 0.96), significantly higher than the 0.76 (95% CI 0.65 to 0.85) in patients without imaging selection. Only two complications occurred (0.15%).
Watch out: A specificity of 1.00 is partly built into the design: a positive needle aspirate is itself the tissue diagnosis, so false positives are near-impossible by construction. The sensitivity figure is the informative one, and it depends on imaging selection.
Source: Gu P, Zhao YZ, Jiang LY, Zhang W et al.. Endobronchial ultrasound-guided transbronchial needle aspiration for staging of lung cancer: a systematic review and meta-analysis. European journal of cancer (Oxford, England : 1990). 2009. PMID: 19124238. Registry ID: not stated in the record. MeSH: Area Under Curve · Biopsy, Needle · Endosonography · Humans · Lung Neoplasms · Lymph Nodes · Lymphatic Metastasis · Middle Aged · Neoplasm Staging · Sensitivity and Specificity · Ultrasonography, Interventional
Card 2 — Second staging synthesis: pooled sensitivity 0.88 / specificity 1.00, area under the summary curve 0.99 (Adams 2009)
Study: Systematic review and meta-analysis of 10 accuracy studies (N not stated in the record)
Population: Systematic review of EBUS-TBNA for mediastinal node staging in known or suspected lung cancer: of 365 publications, 10 studies had data suitable for extraction and pooled analysis. The record does not state the pooled participant total, and none is printed here.
Summary: Second staging synthesis: pooled sensitivity 0.88 / specificity 1.00, area under the summary curve 0.99 (Adams 2009)
Result: Pooled specificity was 1.00 (95% CI 0.92 to 1.00) and pooled sensitivity 0.88 (95% CI 0.79 to 0.94), with an area under the summary receiver-operating curve of 0.99 (95% CI 0.96 to 1.00). The authors concluded the results compare favourably with published accuracy for CT and PET.
Watch out: This synthesis and Gu 2009 (card 1) draw on substantially the same early primary studies: they corroborate each other but are not independent evidence, and both predate modern staging pathways.
Source: Adams K, Shah PL, Edmonds L, Lim E et al.. Test performance of endobronchial ultrasound and transbronchial needle aspiration biopsy for mediastinal staging in patients with lung cancer: systematic review and meta-analysis. Thorax. 2009. PMID: 19454408. Registry ID: not stated in the record. MeSH: Biopsy, Needle · Bronchoscopy · Endosonography · Epidemiologic Methods · Humans · Lung Neoplasms · Lymph Nodes · Lymphatic Metastasis · Mediastinum · Neoplasm Staging
Card 3 — The radiologically normal mediastinum: pooled sensitivity only 49% at specificity 100% for occult N2/N3 disease (Leong 2019)
Study: Systematic review and meta-analysis of 9 accuracy studies (N = 1,146)
Population: Systematic review and meta-analysis of EBUS-TBNA for systematic mediastinal staging in clinical N0/N1 lung cancer with a radiologically normal mediastinum: 9 studies (1,146 patients) in the quantitative analysis; mean prevalence of N2/N3 disease was 15% (range 6% to 24%).
Summary: The radiologically normal mediastinum: pooled sensitivity only 49% at specificity 100% for occult N2/N3 disease (Leong 2019)
Result: Pooled sensitivity was 49% (95% CI 41% to 57%) and pooled specificity 100% (95% CI 99% to 100%) for unsuspected N2/N3 metastases, with a mean negative predictive value of 91% (range 82% to 100%). The number needed to test to detect one case of occult N2/N3 disease was 14 (95% CI 10.8 to 16.3), halving when per-oesophageal endoscopic ultrasound was added. The authors advise that verification of negative results by mediastinoscopy remains of value in selected cases.
Watch out: A 91% negative predictive value at 15% prevalence still leaves roughly 1 in 11 negative-staged patients harbouring nodal disease: the miss rate matters most exactly where the result would change the decision to operate.
Source: Leong TL, Loveland PM, Gorelik A, Irving L et al.. Preoperative Staging by EBUS in cN0/N1 Lung Cancer: Systematic Review and Meta-Analysis. Journal of bronchology & interventional pulmonology. 2019. PMID: 30119069. Registry ID: not stated in the record. MeSH: Bronchoscopy · Carcinoma, Non-Small-Cell Lung · Endoscopic Ultrasound-Guided Fine Needle Aspiration · Humans · Lung Neoplasms · Lymph Nodes · Lymphatic Metastasis · Mediastinum · Neoplasm Staging · Predictive Value of Tests · Preoperative Period