SourceMed · Shelf #10045 in the ask interface
Connected and sensor-monitored inhaler systems for asthma: adherence rose about 11–12 percentage points and reliever use fell in two randomised trials, but asthma control scores did not differ between groups overall
Shelf #10045 · Lungs, breathing & sleep
SPLIT (by outcome)
Stamped: 2026-11-28.
Evidence published: 2016–2021.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In people with asthma, do connected inhaler systems — clip-on sensors with feedback to the patient, and in some arms to the clinician — improve maintenance-inhaler adherence, reliever use and asthma control compared with the same inhalers without feedback?
Balance of the evidence
SPLIT (by outcome) — Composition: two independent randomised trials of sensor-based inhaler monitoring with feedback. The Propeller Health Asthma Platform trial (Merchant 2016; 495 patients monitored for 12 months; the platform is named as published under the tested-product clarification exception — sensor systems are not FDA-approved drugs and differ by maker, and no manufacturer beyond the platform name is stated in the record) tracked reliever use with feedback to patients and proactive notifications to physicians. The connected inhaler system trial (Moore 2021; 437 adults with uncontrolled asthma; NCT03380429) attached sensors to maintenance and rescue inhalers and varied who received the data across five arms. The documented base is 932 patients, above the 30 minimum. Adherence and reliever outcomes moved: maintenance adherence over months 4–6 was 82.2% with feedback to patient and clinician against a control-arm level that gave an adjusted difference of 12.0 percentage points (95% CI 5.2 to 18.8; Moore 2021), and daily reliever use fell more and reliever-free days rose more with the Propeller platform (Merchant 2016). Asthma control did not: Asthma Control Test scores were not significantly different between arms in the whole Propeller population (improvement appeared only in the subgroup uncontrolled at baseline, 63% versus 49% reaching control) and did not differ between groups in Moore 2021 despite the adherence gain. SPLIT (by outcome): connected inhalers reliably change the process measures they feed back — adherence up, reliever use down — while a corresponding gain in measured asthma control has not been shown in the overall trial populations.
MeSH: Adrenergic beta-Agonists · Adult · Anti-Asthmatic Agents · Asthma · Child · Drug Utilization · Female · Humans · Male · Metered Dose Inhalers · Telemedicine · Administration, Inhalation · Albuterol · Bronchodilator Agents · Drug Combinations · Medication Adherence · Nebulizers and Vaporizers
Cards (2)
Card 1 — Propeller platform trial (495 patients, 12 months): reliever use fell further and reliever-free days rose further with feedback; control scores differed only in the initially uncontrolled subgroup (Merchant 2016)
Study: Pragmatic randomised controlled trial (N = 495)
Population: Pragmatic randomised trial of 495 patients with asthma, enrolled in parallel arms (1:1) for 12 months of monitoring of short-acting beta-agonist use. The intervention group received access to and feedback from the Propeller Health Asthma Platform (named as published; the record states no manufacturer beyond the platform name); routine-care patients wore sensors but received no feedback, and physicians could monitor intervention patients and receive proactive notifications.
Summary: Propeller platform trial (495 patients, 12 months): reliever use fell further and reliever-free days rose further with feedback; control scores differed only in the initially uncontrolled subgroup (Merchant 2016)
Result: Daily mean reliever uses per person fell by 0.41 in the intervention group and 0.31 in routine care between the first week and the rest of the study (P < .001 for the between-group difference); the proportion of reliever-free days rose 21% versus 17% (P < .01). Asthma Control Test scores were not significantly different between arms in the entire population; among adults uncontrolled at baseline, 63% in the intervention group versus 49% in routine care had controlled asthma during the study period (P < .05 comparing the improvements).
Watch out: Both arms wore sensors, so the trial tests feedback on top of being monitored, not monitoring itself; and the headline control benefit rests on a subgroup (initially uncontrolled adults), not the randomised population as a whole.
Source: Merchant RK, Inamdar R, Quade RC. Effectiveness of Population Health Management Using the Propeller Health Asthma Platform: A Randomized Clinical Trial. The journal of allergy and clinical immunology. In practice. 2016. PMID: 26778246. Registry ID: not stated in the record. MeSH: Adrenergic beta-Agonists · Adult · Anti-Asthmatic Agents · Asthma · Child · Drug Utilization · Female · Humans · Male · Metered Dose Inhalers · Telemedicine
Card 2 — Connected inhaler system trial (437 adults): maintenance adherence 82.2% versus 70.8% observed in the full-feedback arm versus control (adjusted difference 12.0 points), with no between-group difference in control scores (Moore 2021)
Study: Randomised controlled trial, five arms (N = 437)
Population: Open-label, five-arm, 6-month randomised trial in 437 adults with uncontrolled asthma (Asthma Control Test score below 20) on fixed-dose inhaled corticosteroid/long-acting beta-agonist maintenance therapy. All participants used sensor-fitted maintenance and rescue inhalers; arms varied whether maintenance and rescue data were fed back to participants, to healthcare professionals, to both, or to neither (control, n = 86).
Summary: Connected inhaler system trial (437 adults): maintenance adherence 82.2% versus 70.8% observed in the full-feedback arm versus control (adjusted difference 12.0 points), with no between-group difference in control scores (Moore 2021)
Result: For the primary endpoint, observed mean adherence to maintenance therapy over months 4–6 was 82.2% (SD 16.58) in the arm feeding maintenance data to participants and professionals, versus 70.8% (SD 27.30) in control — an adjusted difference of 12.0% (95% CI 5.2 to 18.8; p < 0.001); adherence was also significantly greater in the other feedback arms than control. Rescue-free days were significantly more frequent in arms receiving rescue-use data. Asthma Control Test scores improved in all arms with no significant differences between groups.
Watch out: Adherence here is doses taken as recorded by the sensor, in a trial where everyone knew their inhalers were instrumented; the trial was not powered to show exacerbation differences, and none in control scores appeared despite a 12-point adherence gap.
Source: Moore A, Preece A, Sharma R, Heaney LG et al.. A randomised controlled trial of the effect of a connected inhaler system on medication adherence in uncontrolled asthmatic patients. The European respiratory journal. 2021. PMID: 33334936. Registry ID: NCT03380429. MeSH: Administration, Inhalation · Adult · Albuterol · Anti-Asthmatic Agents · Asthma · Bronchodilator Agents · Drug Combinations · Humans · Medication Adherence · Nebulizers and Vaporizers
Estimate type: adjusted estimate, as stated in the card.