SourceMed · Shelf #10079 in the ask interface

Sentinel lymph node biopsy in early cervical cancer (SENTICOL): sensitivity 92.0% and negative predictive value 98.2% against full lymphadenectomy — but there were no false negatives only when sentinel nodes were detected on both sides

Shelf #10079 · Cancer

MEASUREMENT ACCURACY — PARTIAL

Stamped: 2026-11-28.

Evidence published: 2011.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In women with early cervical cancer (stage IA1 with lymphovascular invasion to IB1), how accurately does sentinel lymph node biopsy with combined technetium and blue-dye mapping detect lymph node metastasis, against complete pelvic and/or para-aortic lymphadenectomy with histology as the reference standard?

Balance of the evidence

MEASUREMENT ACCURACY — PARTIAL — Composition: a single prospective multicentre accuracy study (SENTICOL) in 145 enrolled patients (139 in the modified intention-to-diagnose analysis) with stage IA1 (with lymphovascular space invasion) to IB1 cervical carcinoma, in which sentinel node biopsy with technetium-99 lymphoscintigraphy and Patent Blue was checked against complete lymphadenectomy histology (Lécuru 2011). The documented base is 139 analysed patients, above the 30 minimum. Sensitivity and specificity are labelled in words at first occurrence where a pair is stated; this study reports sensitivity and negative predictive value rather than a specificity pair: sensitivity was 92.0% (23 of 25; 95% CI 74.0 to 99.0) and negative predictive value 98.2% (111 of 113) for node metastasis, with at least one sentinel node detected in 97.8% of patients. The qualification is decisive: the two false negatives both occurred without bilateral detection, and among the 104 patients (76.5%) with bilaterally detected sentinel nodes there were no false negatives — so the test's reassurance is conditional on bilateral mapping, which failed in about a quarter of patients. Diagnosis-first framing: the question is the accuracy of the staging test, not whether omitting lymphadenectomy improves outcomes, which this study does not test. MEASUREMENT ACCURACY — PARTIAL: sentinel node biopsy is accurate when nodes are found on both sides, and not fully reliable when mapping is unilateral.

MeSH: Adolescent · Adult · Female · Humans · Lymphatic Metastasis · Middle Aged · Neoplasm Staging · Predictive Value of Tests · Sentinel Lymph Node Biopsy · Uterine Cervical Neoplasms

Cards (1)

Card 1 — SENTICOL (139 analysed): sentinel node biopsy sensitivity 92.0%, negative predictive value 98.2% for nodal metastasis; both false negatives occurred without bilateral detection (Lécuru 2011)

Study: Prospective diagnostic accuracy study (N = 139 analysed)

Population: 145 adults with cervical carcinoma, FIGO stage IA1 with lymphovascular space invasion to stage IB1, enrolled in a prospective multicentre study; 139 were included in the modified intention-to-diagnose analysis. All underwent technetium-99 lymphoscintigraphy and Patent Blue injection, laparoscopic sentinel node mapping and removal, then full lymph node dissection as the reference standard; negative sentinel nodes underwent ultrastaging, and only surgeons trained in the technique participated.

Summary: SENTICOL (139 analysed): sentinel node biopsy sensitivity 92.0%, negative predictive value 98.2% for nodal metastasis; both false negatives occurred without bilateral detection (Lécuru 2011)

Result: At least one sentinel node was detected in 136 patients (97.8%; 95% CI 93.8 to 99.6). There were 23 true-positive and 2 false-negative results, giving sensitivity of 92.0% (23 of 25; 95% CI 74.0 to 99.0) and a negative predictive value of 98.2% (111 of 113). No false-negative results occurred in the 104 patients (76.5%) in whom sentinel nodes were identified bilaterally. The study's conclusion: combined labelling gives high detection, sensitivity, and negative predictive value, but sentinel node biopsy was fully reliable only when sentinel nodes were detected bilaterally.

Watch out: Only 25 patients had nodal metastasis, so the sensitivity estimate rests on 25 positive cases and its confidence interval runs from 74% to 99%. Accuracy here does not by itself prove that omitting full lymphadenectomy after a negative bilateral sentinel node is oncologically safe — that is an outcomes question this study was not designed to answer.

Source: Lécuru F, Mathevet P, Querleu D et al. Bilateral negative sentinel nodes accurately predict absence of lymph node metastasis in early cervical cancer: results of the SENTICOL study. Journal of Clinical Oncology. 2011. PMID: 21444878. Registry ID: not stated in the record. MeSH: Adolescent · Adult · Female · Humans · Lymphatic Metastasis · Middle Aged · Neoplasm Staging · Predictive Value of Tests · Sentinel Lymph Node Biopsy · Uterine Cervical Neoplasms