SourceMed · Shelf #10081 in the ask interface

Sentinel lymph node biopsy after neoadjuvant chemotherapy in initially node-positive breast cancer: false-negative rates of 12.6% (Z1071), 14.2% (SENTINA), and 8.4% (SN FNAC, with mandatory immunohistochemistry) against completion axillary dissection

Shelf #10081 · Cancer

MEASUREMENT ACCURACY — PARTIAL

Stamped: 2026-11-28.

Evidence published: 2013–2015.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In women with biopsy-proven node-positive breast cancer who receive neoadjuvant chemotherapy, how accurate is sentinel lymph node biopsy after chemotherapy — its false-negative rate and identification rate — against completion axillary lymph node dissection as the reference standard?

Balance of the evidence

MEASUREMENT ACCURACY — PARTIAL — Composition: three prospective multicentre accuracy studies of sentinel lymph node biopsy after neoadjuvant chemotherapy in initially node-positive breast cancer, each checked against completion axillary dissection: ACOSOG Z1071 (756 enrolled; Boughey 2013; NCT00881361), SENTINA arm C and related arms (1,737 treated; Kuehn 2013), and SN FNAC (153 accrued; Boileau 2015). The documented base is 2,646 enrolled patients across the three studies, above the 30 minimum. Sensitivity and specificity are labelled in words at first occurrence where a pair is stated; these studies report the false-negative rate — the complement of sensitivity — rather than specificity pairs: the false-negative rate was 12.6% in Z1071 among patients with two or more sentinel nodes examined (above the 10% rate the trial set as acceptable), 14.2% in SENTINA's converted-to-node-negative arm, and 8.4% in SN FNAC, the one study mandating immunohistochemistry and counting metastases of any size as positive. Technique moves the number: single-node removal and repeat biopsy after a prior sentinel procedure performed far worse (false-negative rates 24.3% and 51.6% in SENTINA arms). Diagnosis-first framing: this shelf grades the staging test; whether omitting axillary dissection on a negative post-chemotherapy sentinel node is safe is an outcomes question these accuracy studies do not answer. MEASUREMENT ACCURACY — PARTIAL: post-chemotherapy sentinel biopsy misses roughly one in eight to one in seven involved axillae under standard technique, approaching acceptable accuracy only with mandatory immunohistochemistry and multiple nodes examined.

MeSH: Adult · Aged · Aged, 80 and over · Antineoplastic Combined Chemotherapy Protocols · Axilla · Breast Neoplasms · Carcinoma, Ductal, Breast · Carcinoma, Lobular · Chemotherapy, Adjuvant · Colloids · Coloring Agents · False Negative Reactions · Female · Follow-Up Studies · Humans · Immunohistochemistry · Lymph Node Excision · Lymph Nodes · Lymphatic Metastasis · Mastectomy · Middle Aged · Neoadjuvant Therapy · Neoplasm Invasiveness · Neoplasm Staging · Prognosis · Prospective Studies · Radiopharmaceuticals · Sentinel Lymph Node Biopsy · Young Adult

Cards (3)

Card 1 — ACOSOG Z1071 (649 undergoing both procedures; 525 with 2+ sentinel nodes): false-negative rate 12.6% after chemotherapy in cN1 disease — above the trial's 10% acceptability threshold (Boughey 2013)

Study: Prospective diagnostic accuracy study (N = 756 enrolled)

Population: 756 women with clinical T0–T4, N1–N2, M0 breast cancer at 136 institutions who received neoadjuvant chemotherapy and then underwent both sentinel lymph node surgery and axillary dissection; 663 were evaluable with cN1 disease and 649 had both procedures. Dual mapping with blue dye and radiolabelled colloid was encouraged.

Summary: ACOSOG Z1071 (649 undergoing both procedures; 525 with 2+ sentinel nodes): false-negative rate 12.6% after chemotherapy in cN1 disease — above the trial's 10% acceptability threshold (Boughey 2013)

Result: A sentinel node was not identified in 46 patients (7.1%), and only one sentinel node was excised in 78 (12.0%). Among the 525 patients with two or more sentinel nodes removed, 215 had no cancer in any axillary node (pathological complete nodal response 41.0%; 95% CI 36.7 to 45.3). In 39 patients cancer was absent from the sentinel nodes but present in dissection nodes, a false-negative rate of 12.6% (90% Bayesian credible interval 9.85 to 16.05). The trial concluded the false-negative rate was not shown to be 10% or less.

Watch out: The headline 12.6% applies only to the subgroup with two or more sentinel nodes examined; counting everyone in whom mapping was attempted, performance is worse. The 10% threshold was imported from upfront (cN0) sentinel biopsy practice, not derived from outcomes after chemotherapy.

Source: Boughey JC, Suman VJ, Mittendorf EA et al. Sentinel lymph node surgery after neoadjuvant chemotherapy in patients with node-positive breast cancer: the ACOSOG Z1071 (Alliance) clinical trial. JAMA. 2013. PMID: 24101169. Registry ID: NCT00881361. MeSH: Adult · Aged · Axilla · Breast Neoplasms · Chemotherapy, Adjuvant · Colloids · Coloring Agents · False Negative Reactions · Female · Humans · Lymph Node Excision · Lymph Nodes · Lymphatic Metastasis · Mastectomy · Middle Aged · Neoadjuvant Therapy · Radiopharmaceuticals · Sentinel Lymph Node Biopsy · Young Adult

Card 2 — SENTINA (1,737 treated): after conversion from cN+ to ycN0, sentinel biopsy detection rate 80.1% and false-negative rate 14.2%; a repeat sentinel procedure after earlier sentinel biopsy had a 51.6% false-negative rate (Kuehn 2013)

Study: Prospective diagnostic accuracy cohort (N = 1,737 treated)

Population: 1,737 women with breast cancer scheduled for neoadjuvant chemotherapy at 103 institutions in Germany and Austria, in a four-arm prospective cohort: sentinel biopsy before chemotherapy if clinically node-negative (arms A/B), and after chemotherapy in patients converting from clinically node-positive to node-negative (arm C, 592 patients), with axillary dissection as reference.

Summary: SENTINA (1,737 treated): after conversion from cN+ to ycN0, sentinel biopsy detection rate 80.1% and false-negative rate 14.2%; a repeat sentinel procedure after earlier sentinel biopsy had a 51.6% false-negative rate (Kuehn 2013)

Result: Sentinel biopsy before chemotherapy detected a node in 99.1% (1,013 of 1,022). In arm C (conversion cN+ to ycN0), the detection rate was 80.1% (95% CI 76.6 to 83.2; 474 of 592) and the false-negative rate 14.2% (95% CI 9.9 to 19.4; 32 of 226) — 24.3% (17 of 70) when one node was removed and 18.5% (10 of 54) with two nodes. In arm B (a second sentinel procedure after chemotherapy in patients whose pre-chemotherapy sentinel node was positive), detection was 60.8% and the false-negative rate 51.6% (95% CI 38.7 to 64.2; 33 of 64).

Watch out: The four arms answer different timing questions; only arm C matches the initially node-positive, post-chemotherapy question. The 51.6% false-negative rate for repeat sentinel biopsy is a strong negative result for that specific manoeuvre, not for first-time post-chemotherapy biopsy.

Source: Kuehn T, Bauerfeind I, Fehm T et al. Sentinel-lymph-node biopsy in patients with breast cancer before and after neoadjuvant chemotherapy (SENTINA): a prospective, multicentre cohort study. The Lancet. Oncology. 2013. PMID: 23683750. Registry ID: not stated in the record. MeSH: Adult · Aged · Aged, 80 and over · Antineoplastic Combined Chemotherapy Protocols · Breast Neoplasms · Carcinoma, Ductal, Breast · Carcinoma, Lobular · Chemotherapy, Adjuvant · False Negative Reactions · Female · Follow-Up Studies · Humans · Lymph Nodes · Lymphatic Metastasis · Middle Aged · Neoadjuvant Therapy · Neoplasm Invasiveness · Neoplasm Staging · Prognosis · Prospective Studies · Sentinel Lymph Node Biopsy · Young Adult

Card 3 — SN FNAC (153 accrued): false-negative rate 8.4% with mandatory immunohistochemistry and any-size metastases counted positive; identification rate 87.6% (Boileau 2015)

Study: Prospective diagnostic accuracy study (N = 153 accrued)

Population: 153 patients with biopsy-proven node-positive breast cancer (T0–3, N1–2) accrued to a prospective multicentre study; all underwent sentinel node biopsy and completion node dissection after neoadjuvant chemotherapy, with mandatory immunohistochemistry of sentinel nodes and metastases of any size, including isolated tumour cells (0.2 mm or smaller), counted as positive. Predetermined targets were an identification rate of at least 90% and a false-negative rate of at most 10%.

Summary: SN FNAC (153 accrued): false-negative rate 8.4% with mandatory immunohistochemistry and any-size metastases counted positive; identification rate 87.6% (Boileau 2015)

Result: The identification rate was 87.6% (127 of 145; 95% CI 82.2 to 93.0) — below the 90% target — and the false-negative rate was 8.4% (7 of 83; 95% CI 2.4 to 14.4), within the 10% target. Had isolated tumour cell deposits been counted as negative, the false-negative rate would have risen to 13.3% (11 of 83; 95% CI 6.0 to 20.6). By this method, 30.3% of patients could potentially have avoided completion dissection.

Watch out: The lowest false-negative rate of the three studies was bought with the strictest pathology (mandatory immunohistochemistry, isolated tumour cells counted positive) in the smallest study — its 95% confidence interval (2.4% to 14.4%) overlaps the other studies' point estimates, and the identification-rate target was missed.

Source: Boileau JF, Poirier B, Basik M et al. Sentinel node biopsy after neoadjuvant chemotherapy in biopsy-proven node-positive breast cancer: the SN FNAC study. Journal of Clinical Oncology. 2015. PMID: 25452445. Registry ID: not stated in the record. MeSH: Adult · Aged · Antineoplastic Combined Chemotherapy Protocols · Axilla · Breast Neoplasms · Chemotherapy, Adjuvant · Female · Humans · Immunohistochemistry · Lymph Node Excision · Lymph Nodes · Lymphatic Metastasis · Middle Aged · Neoadjuvant Therapy · Prospective Studies · Sentinel Lymph Node Biopsy