SourceMed · Shelf #10091 in the ask interface
Hysterosalpingography against laparoscopy: a rule-in test — specificity 83–95% but sensitivity only 46–65%, falling to 13% for bilateral disease in women without risk factors
Shelf #10091 · Women’s health
MEASUREMENT ACCURACY — PARTIAL
Stamped: 2026-11-28.
Evidence published: 1995–2011.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
How accurately does hysterosalpingography diagnose tubal patency and tubal pathology against laparoscopy with chromopertubation — and how does its accuracy change with the woman's risk profile and age?
Balance of the evidence
MEASUREMENT ACCURACY — PARTIAL — Composition: 2 syntheses against laparoscopy with chromopertubation — a conventional meta-analysis of 20 studies (4,179 patients; Swart 1995) and an individual patient data meta-analysis of 7 primary studies (4,521 women; Broeze 2011). The individual patient data set overlaps the earlier literature, so the two Ns corroborate rather than add, and are not summed. Sensitivity and specificity are labelled in words at first occurrence: in the subset of studies that assessed the two tests independently, hysterosalpingography had sensitivity 0.65 / specificity 0.83 for tubal patency (Swart 1995). The individual patient data pooling split the target: sensitivity 53% / specificity 87% for any tubal pathology, and sensitivity 46% / specificity 95% for bilateral tubal pathology (Broeze 2011). Accuracy depends on who is tested: in women without risk factors for tubal pathology, sensitivity fell to 38% for any pathology and 13% for bilateral pathology, against 61% and 47% in women with risk factors, while specificity stayed stable across subgroups; sensitivity for bilateral pathology also fell with age (factor 0.93 per year). For peritubal adhesions the older synthesis found hysterosalpingography not reliable. The pattern is a rule-in test: high specificity makes a positive (occluded) reading credible, while sensitivity near or below one half means a patent reading misses much disease. Boundary: hysterosalpingography as a fertility treatment (oil versus water contrast flushing) is homed in pack #1330; this pack covers only its diagnostic accuracy. MEASUREMENT ACCURACY — PARTIAL: hysterosalpingography rules tubal occlusion in far better than it rules it out, and its sensitivity collapses in exactly the low-risk women most likely to be screened with it.
MeSH: Fallopian Tube Diseases · Female · Humans · Hysterosalpingography · Infertility, Female · ROC Curve · Sensitivity and Specificity · Tissue Adhesions · Adult · Age Factors · Fallopian Tube Patency Tests · Regression Analysis · Risk Factors · Time Factors
Cards (2)
Card 1 — Against laparoscopy, hysterosalpingography read tubal patency at sensitivity 0.65 / specificity 0.83 — and was not reliable for peritubal adhesions (Swart 1995)
Study: Meta-analysis (20 studies, N = 4,179)
Population: Meta-analysis of 20 studies (4,179 patients with infertility) comparing hysterosalpingography with laparoscopy with chromopertubation as the reference standard, for tubal patency and for peritubal adhesions.
Summary: Against laparoscopy, hysterosalpingography read tubal patency at sensitivity 0.65 / specificity 0.83 — and was not reliable for peritubal adhesions (Swart 1995)
Result: Sensitivity and specificity are labelled in words at first occurrence: for tubal patency the reported sensitivity and specificity differed between studies; in the subset of studies that evaluated hysterosalpingography and laparoscopy independently, a point estimate of sensitivity 0.65 and specificity 0.83 was calculated. For peritubal adhesions only a summary receiver-operating-characteristic curve could be estimated. The authors concluded that hysterosalpingography is of limited use for detecting tubal patency because of its low sensitivity, that its high specificity makes it useful for ruling in tubal obstruction, and that it is not reliable for peritubal adhesions.
Watch out: A 1995 synthesis of studies with variable designs; the headline pair comes only from the subset with independent test assessment — the full set was too heterogeneous for one estimate.
Source: Swart, Mol, van der Veen, van Beurden et al.. The accuracy of hysterosalpingography in the diagnosis of tubal pathology: a meta-analysis. Fertility and sterility. 1995. PMID: 7641899. Registry ID: not stated in the record. MeSH: Fallopian Tube Diseases · Female · Humans · Hysterosalpingography · Infertility, Female · ROC Curve · Sensitivity and Specificity · Tissue Adhesions
Card 2 — Individual patient data: sensitivity 53% / specificity 87% for any tubal pathology and 46% / 95% for bilateral disease — but sensitivity fell to 13% for bilateral disease in women without risk factors (Broeze 2011)
Study: Individual patient data meta-analysis (7 studies, N = 4,521)
Population: Individual patient data meta-analysis of 7 primary studies (4,521 women) of hysterosalpingography against laparoscopy, testing whether accuracy varies with female age, duration of subfertility and absence of risk factors for tubal pathology.
Summary: Individual patient data: sensitivity 53% / specificity 87% for any tubal pathology and 46% / 95% for bilateral disease — but sensitivity fell to 13% for bilateral disease in women without risk factors (Broeze 2011)
Result: Pooled sensitivity and specificity of hysterosalpingography were 53% and 87% for any tubal pathology and 46% and 95% for bilateral tubal pathology. In women without risk factors, sensitivity was 38% for any tubal pathology versus 61% in women with risk factors (P = 0.005); for bilateral tubal pathology the rates were 13% versus 47% (P = 0.01). Sensitivity for bilateral pathology decreased with age (factor 0.93 per year, P = 0.05), while specificity was very stable across all subgroups. The authors note the low sensitivity in women without risk factors may partly reflect false-positive results at laparoscopy, and concluded hysterosalpingography is a useful tubal patency screening test for all infertile couples.
Watch out: The reference standard is imperfect — some 'missed' disease may be laparoscopy's error, as the authors themselves raise — and the 13% bilateral sensitivity in low-risk women is the figure that should govern screening use.
Source: Broeze, Opmeer, Van Geloven, Coppus et al.. Are patient characteristics associated with the accuracy of hysterosalpingography in diagnosing tubal pathology? An individual patient data meta-analysis. Human reproduction update. 2011. PMID: 21147835. Registry ID: not stated in the record. MeSH: Adult · Age Factors · Fallopian Tube Diseases · Fallopian Tube Patency Tests · Female · Humans · Hysterosalpingography · Infertility, Female · Regression Analysis · Risk Factors · Sensitivity and Specificity · Time Factors