SourceMed · Shelf #10097 in the ask interface
Soluble ST2 and galectin-3 for heart-failure prognosis: both markers track risk in pooled cohorts — per doubling of sST2, a hazard ratio of 1.75 for death — but no record here shows either marker improving a clinical prediction model
Shelf #10097 · Heart, vessels, blood pressure & clotting
PREDICTIVE PERFORMANCE — PARTIAL
Stamped: 2026-11-28.
Evidence published: 2017–2026.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In people with chronic heart failure, or at risk of it, how well do circulating soluble ST2 and galectin-3 predict death, heart-failure hospitalisation or new heart failure — and is there evidence they add predictive performance beyond standard clinical assessment?
Balance of the evidence
PREDICTIVE PERFORMANCE — PARTIAL — Composition: three meta-analyses — soluble ST2 (sST2) and death in chronic heart failure outpatients (7 studies, 6,372 patients; Aimo 2017), sST2 in chronic heart failure updated to 2024 (17 studies; pooled patient total not stated in the record; Zhang 2026), and galectin-3 and incident heart failure (9 studies; pooled patient total not stated in the record; Baccouche 2023). Association is not in doubt: per doubling of sST2, the pooled hazard ratio was 1.75 (95% CI 1.37 to 2.22) for all-cause death and 1.79 (95% CI 1.22 to 2.63) for cardiovascular death (Aimo 2017), with significant heterogeneity the authors attribute partly to differences in background treatment; the updated synthesis found high sST2 associated with the composite of death or heart-failure readmission (hazard ratio 1.46, 95% CI 1.33 to 1.61). For galectin-3, the top versus bottom quartile carried a hazard ratio of 1.97 (95% CI 1.74 to 2.23) for incident heart failure in minimally adjusted models, attenuating to 1.32 (95% CI 1.21 to 1.44) after fuller adjustment — the attenuation itself is the finding: much of the marker's signal is shared with the risk factors clinicians already measure. What none of the three records reports is the quantity a prediction claim needs — a change in discrimination (c-statistic) or reclassification when the marker is added to a clinical model — so this pack grades association, and states plainly that added predictive performance is not established by these records. No sensitivity/specificity pair arises: these are prognostic hazard ratios, not diagnostic thresholds, and none is invented. PREDICTIVE PERFORMANCE — PARTIAL: sST2 and galectin-3 are genuine risk markers in heart failure; their value as additions to clinical prediction is unproven on this evidence.
MeSH: Cardiovascular Diseases · Cause of Death · Chronic Disease · Heart Failure · Humans · Interleukin-1 Receptor-Like 1 Protein · Mortality · Prognosis · Proportional Hazards Models · Galectin 3 · Biomarkers · Incidence · Risk Factors · Male · Female
Cards (3)
Card 1 — sST2 meta-analysis (7 studies, 6,372 outpatients): each doubling of sST2 carried a hazard ratio of 1.75 for all-cause death and 1.79 for cardiovascular death (Aimo 2017)
Study: Meta-analysis of prognostic cohorts (7 studies, N = 6,372)
Population: Meta-analysis of follow-up studies of chronic heart failure outpatients using a standardised sST2 assay, reporting hazard ratios per log2 (doubling) of sST2: 7 studies, 6,372 patients for all-cause death; 5 studies, 5,051 patients for cardiovascular death. Studies of end-stage heart failure and of sST2 used only inside a prognostic score were excluded.
Summary: sST2 meta-analysis (7 studies, 6,372 outpatients): each doubling of sST2 carried a hazard ratio of 1.75 for all-cause death and 1.79 for cardiovascular death (Aimo 2017)
Result: The pooled hazard ratio per doubling of sST2 was 1.75 (95% CI 1.37 to 2.22) for all-cause death and 1.79 (95% CI 1.22 to 2.63) for cardiovascular death (both p < 0.001). Significant heterogeneity was detected, attributed by the authors to marked differences in pharmacological treatment among studies; predictive power was greater in patients managed with guideline-recommended treatment.
Watch out: A hazard ratio per doubling is an association gradient, not a test: the record reports no c-statistic, calibration or reclassification analysis, so it cannot by itself justify measuring sST2 in an individual patient.
Source: Aimo A, Vergaro G, Passino C, Ripoli A et al.. Prognostic Value of Soluble Suppression of Tumorigenicity-2 in Chronic Heart Failure: A Meta-Analysis. JACC. Heart failure. 2017. PMID: 27816512. Registry ID: not stated in the record. MeSH: Cardiovascular Diseases · Cause of Death · Chronic Disease · Heart Failure · Humans · Interleukin-1 Receptor-Like 1 Protein · Mortality · Prognosis · Proportional Hazards Models
Card 2 — Updated sST2 synthesis (17 studies): high sST2 predicted death or heart-failure readmission (hazard ratio 1.46) and cardiovascular death or hospitalisation (hazard ratio 1.50) (Zhang 2026)
Study: Systematic review and meta-analysis (17 studies; pooled N not stated in the record)
Population: Systematic review and meta-analysis (PROSPERO CRD42023489018, as stated in the record) of studies of circulating soluble ST2 in chronic heart failure published to 1 September 2024: 17 studies included; the record does not state a pooled patient total, and none is printed here.
Summary: Updated sST2 synthesis (17 studies): high sST2 predicted death or heart-failure readmission (hazard ratio 1.46) and cardiovascular death or hospitalisation (hazard ratio 1.50) (Zhang 2026)
Result: High soluble ST2 was associated with all-cause mortality (hazard ratio 1.03, 95% CI 1.02 to 1.04, on the record's per-unit scaling), with all-cause mortality or heart-failure readmission (hazard ratio 1.46, 95% CI 1.33 to 1.61), and with cardiovascular mortality or heart-failure hospitalisation (hazard ratio 1.50, 95% CI 1.30 to 1.74), each p < 0.00001, with consistent subgroup findings by ethnicity, sex, ejection fraction and follow-up duration.
Watch out: Its study pool overlaps the earlier Aimo synthesis carded above, and its headline mortality hazard ratio (1.03) uses a per-unit scaling that is not comparable with the per-doubling figure on the neighbouring card — the two numbers describe the same association on different rulers.
Source: Zhang Y, Liu Y, Yang Y, Peng L et al.. The prognostic value of circulating soluble ST2 in patients with chronic heart failure. The Journal of international medical research. 2026. PMID: 41529919. Registry ID: not stated in the record. MeSH: Humans · Heart Failure · Interleukin-1 Receptor-Like 1 Protein · Prognosis · Biomarkers · Chronic Disease · Male · Female
Card 3 — Galectin-3 and incident heart failure (9 studies): top versus bottom quartile hazard ratio 1.97 minimally adjusted, attenuating to 1.32 after fuller adjustment (Baccouche 2023)
Study: Meta-analysis of prognostic cohorts (9 studies; pooled N not stated in the record)
Population: Meta-analysis of published cohort studies relating circulating galectin-3 to the risk of developing heart failure: 9 studies met the criteria and all contributed data; the record does not state a pooled patient total, and none is printed here.
Summary: Galectin-3 and incident heart failure (9 studies): top versus bottom quartile hazard ratio 1.97 minimally adjusted, attenuating to 1.32 after fuller adjustment (Baccouche 2023)
Result: Comparing the top with the bottom quartile of log galectin-3, the hazard ratio for incident heart failure was 1.97 (95% CI 1.74 to 2.23) in minimally adjusted models and 1.32 (95% CI 1.21 to 1.44) in further-adjusted models; the association remained significant in sensitivity analyses.
Watch out: The fall from 1.97 to 1.32 with adjustment is the clinically important number: most of galectin-3's crude signal travels with age, kidney function and natriuretic-peptide territory that practice already measures, and the record reports no added-discrimination analysis.
Source: Baccouche BM, Mahmoud MA, Nief C, Patel K et al.. Galectin-3 is Associated with Heart Failure Incidence: A Meta-Analysis. Current cardiology reviews. 2023. PMID: 36397629. Registry ID: not stated in the record. MeSH: Humans · Galectin 3 · Heart Failure · Biomarkers · Incidence · Risk Factors · Prognosis
Estimate type: adjusted estimate, as stated in the card.