Defibrillation strategies for refractory ventricular fibrillation: double sequential and vector change (DOSE VF)
Shelf #1011 · Emergency & first hours
Stamped: development phase, October–November 2026 — exact date not recorded.
Evidence published: 2022.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In refractory VF after three failed standard shocks, does double sequential external defibrillation or vector-change defibrillation improve survival to discharge and good neurological outcome versus continuing standard defibrillation?
Balance of the evidence
POSSIBLE (Tier C: the headline outcomes are survival to discharge and neurological outcome after cardiac arrest). One cluster-randomised trial with crossover (DOSE VF, 405 patients, stopped early when COVID-19 disrupted the trial) found survival to hospital discharge of 30.4% with double sequential defibrillation and 21.7% with vector-change defibrillation vs 13.3% with standard defibrillation (relative risks 2.21 and 1.71 respectively, printed as relative with the absolute rates beside them), and good neurological outcome higher with double sequential (relative risk 2.21) but not significantly with vector change (1.48, CI crossing 1). A single, small, early-stopped trial caps a survival-benefit claim at POSSIBLE; the currency sweep found no confirmatory randomised trial.
MeSH: Canada · Defibrillators · Electric Countershock/adverse effects,instrumentation,methods · Out-of-Hospital Cardiac Arrest/mortality,therapy · Ventricular Fibrillation/mortality,therapy · Cross-Over Studies · Cluster Analysis
Cards (2)
Card 1 — DOSE VF (Cheskes 2022): double sequential defibrillation raised survival to discharge to 30.4% vs 13.3% with standard shocks; vector change gave 21.7%
Study: Cluster-randomised trial with crossover (six Canadian paramedic services; unblindable by nature), stopped early because of the COVID-19 pandemic
Population: 405 adults with refractory ventricular fibrillation during out-of-hospital cardiac arrest (136 standard defibrillation, 144 vector-change, 125 double sequential). The abstract does not state mean age or sex mix.
Summary: DOSE VF 2022: double sequential defibrillation raised survival to discharge to 30.4% vs 13.3% with standard shocks (relative risk 2.21); vector change gave 21.7%.
Result: Survival to hospital discharge was 30.4% with double sequential external defibrillation vs 13.3% with standard defibrillation (relative risk 2.21, 95% CI 1.33 to 3.67) and 21.7% with vector-change defibrillation vs 13.3% (relative risk 1.71, 1.01 to 2.88) — relative figures, with the absolute rates (30.4% and 21.7% vs 13.3%) printed beside them. Good neurological outcome (modified Rankin Scale ≤2 at discharge) was more frequent with double sequential (relative risk 2.21, 1.26 to 3.88) but not significantly with vector change (relative risk 1.48, 0.81 to 2.71). Secondary outcomes included termination of VF and return of spontaneous circulation.
Watch out: One trial, 405 patients, terminated early for pandemic logistics rather than for benefit — early stopping plus cluster crossover means the survival ratios (2.21 sits just above the developer's 2.0 observational floor, but this is a randomised estimate from a small stopped trial) should be read as promising, not settled. No second randomised trial exists to confirm either strategy.
Source: Cheskes S et al. Defibrillation Strategies for Refractory Ventricular Fibrillation. N Engl J Med. 2022;387(21):1947-1956. PMID: 36342151. Registry ID: ClinicalTrials.gov NCT04080986, from the record's databank fields.
Card 2 — Synthesis: a promising single-trial survival signal for double sequential and vector-change defibrillation — POSSIBLE, Tier C
Study: Synthesis
Population: Synthesis of the card above: DOSE VF (405 patients with refractory VF).
Summary: A promising single-trial survival signal with no confirmatory trial — POSSIBLE, Tier C,.
Result: DOSE VF is the only randomised test of defibrillation strategy in refractory VF: both alternative strategies beat continued standard shocks on survival to discharge in absolute terms (30.4% and 21.7% vs 13.3%), and double sequential also improved good neurological outcome. Antiarrhythmic drugs for shock-refractory VF live on Shelf #233 and are not re-carded here.
Watch out: Do not quote the relative risk of 2.21 without the absolute rates (30.4% vs 13.3%) and the stopped-early, 405-patient frame.
Source: Synthesis of Cheskes S et al. N Engl J Med. 2022;387(21):1947-1956. PMID: 36342151. Registry ID as on the card above.