SourceMed · Shelf #10114 in the ask interface

Optical diagnosis of colorectal polyps: digital chromoendoscopy sensitivity 92.2% / specificity 84.0% across 33,123 polyps — the 90% negative-predictive-value bar is met only for high-confidence diminutive rectosigmoid calls

Shelf #10114 · Liver & gut

MEASUREMENT ACCURACY — PARTIAL

Stamped: 2026-11-28.

Evidence published: 2015–2019.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

How accurately can real-time endoscopic optical assessment predict colorectal polyp histology — well enough to support resect-and-discard or diagnose-and-leave strategies?

Balance of the evidence

MEASUREMENT ACCURACY — PARTIAL — Composition: 2 systematic reviews and meta-analyses (102 prospective studies of 33,123 polyps; and the ASGE Technology Committee PIVI assessment) — overlapping syntheses, flagged here and on the cards; the polyp total is counted once. Sensitivity and specificity are labelled in words at first occurrence: digital chromoendoscopy separated neoplasia from benign polyps with sensitivity 92.2% and specificity 84.0%. Accuracy at that level does not clear the adoption bar on its own: the only subgroup with a negative predictive value above 90% was high-confidence prediction of diminutive rectosigmoid polyps, and the PIVI thresholds (negative predictive value 91% pooled for narrow-band imaging; surveillance-interval agreement 90% or more) were met only in academic settings, by experts, and for high-confidence calls — with high heterogeneity (I2 = 89%). Community or low-confidence performance is not established by these records. MEASUREMENT ACCURACY — PARTIAL: optical diagnosis is accurate enough for diagnose-and-leave of high-confidence diminutive rectosigmoid polyps in expert hands, and not established as a general replacement for histopathology.

MeSH: Adenocarcinoma · Adenoma · Adenomatous Polyps · Colonic Polyps · Colonoscopy · Colorectal Neoplasms · Diagnosis, Computer-Assisted · Humans · Microscopy · Narrow Band Imaging · Optical Imaging · Sensitivity and Specificity · Biopsy · Colon · Intestinal Polyps · Models, Statistical · Practice Guidelines as Topic · Predictive Value of Tests · Rectum · United States

Cards (2)

Card 1 — 102-study meta-analysis (33,123 polyps): digital chromoendoscopy sensitivity 92.2% / specificity 84.0%; only high-confidence diminutive rectosigmoid predictions cleared a 90% negative predictive value

Study: Meta-analysis of prospective accuracy studies (102 studies, 33,123 polyps)

Population: Bayesian bivariate meta-analysis of 102 studies that prospectively used an endoscopic optical technology for real-time in vivo prediction of adenomatous histology in 33,123 colorectal polyps; polyposis and inflammatory bowel disease excluded.

Summary: 102-study meta-analysis (33,123 polyps): digital chromoendoscopy sensitivity 92.2% / specificity 84.0%; only high-confidence diminutive rectosigmoid predictions cleared a 90% negative predictive value

Result: Sensitivity and specificity are labelled in words at first occurrence: digital chromoendoscopy (narrow-band imaging, FICE, iSCAN pooled) differentiated neoplasia from benign polyps with sensitivity 92.2% (95% confidence interval 90.6% to 93.9%) and specificity 84.0% (81.5% to 86.3%), with no difference between the constituent technologies or when only diminutive polyps were considered. Dye chromoendoscopy: sensitivity 92.7%, specificity 86.6%. Endomicroscopy: sensitivity 93.6%, specificity 92.5%. Computer-aided diagnosis: sensitivity 88.9%, specificity 80.4%. The only subgroup with a negative predictive value for adenoma above 90% was digital chromoendoscopy making high-confidence predictions of diminutive rectosigmoid polyps; chronological analysis showed falling negative predictive value over time, and publication bias was present.

Watch out: Pooled across technologies and eras; the authors themselves conclude the record is increasingly unlikely to support safe resect-and-discard, and accuracy fell in later studies.

Source: Mason SE, Poynter L, Takats Z, Darzi A, Kinross JM. Optical Technologies for Endoscopic Real-Time Histologic Assessment of Colorectal Polyps: A Meta-Analysis. The American journal of gastroenterology. 2019. PMID: 30848728. Registry ID: not stated in the record. MeSH: Adenocarcinoma · Adenoma · Adenomatous Polyps · Colonic Polyps · Colonoscopy · Colorectal Neoplasms · Diagnosis, Computer-Assisted · Humans · Microscopy · Narrow Band Imaging · Optical Imaging · Sensitivity and Specificity

Card 2 — ASGE PIVI assessment: narrow-band imaging negative predictive value 91% pooled — thresholds met only in academic settings, by experts, at high confidence (I2 = 89%)

Study: Systematic review and meta-analysis (ASGE Technology Committee PIVI assessment)

Population: Systematic review and meta-analysis by the ASGE Technology Committee assessing whether real-time optical biopsy of diminutive (5 mm or smaller) colorectal polyps meets the ASGE Preservation and Incorporation of Valuable endoscopic Innovations (PIVI) thresholds. This synthesis overlaps the 102-study pool carded above and is not added to the documented total.

Summary: ASGE PIVI assessment: narrow-band imaging negative predictive value 91% pooled — thresholds met only in academic settings, by experts, at high confidence (I2 = 89%)

Result: The pooled negative predictive value of narrow-band imaging for adenomatous histology was 91% (95% confidence interval 88% to 94%), exceeding the PIVI threshold, with high heterogeneity (I2 = 89%). Subgroup negative predictive values were above 90% for academic medical centres (91.8%), experts (93%) and high-confidence assessments (93%). Agreement with histopathology-based post-polypectomy surveillance intervals was 90% or greater in academic settings (91%), with experienced endoscopists (92%) and at high confidence (91%).

Watch out: The threshold verdict is conditional — academic centres, experts, high confidence — and rests on a highly heterogeneous pool (I2 = 89%); it does not license optical diagnosis by non-experts or for low-confidence calls.

Source: ASGE Technology Committee, Abu Dayyeh BK, Thosani N, Konda V, Wallace MB, et al. ASGE Technology Committee systematic review and meta-analysis assessing the ASGE PIVI thresholds for adopting real-time endoscopic assessment of the histology of diminutive colorectal polyps. Gastrointestinal endoscopy. 2015. PMID: 25597420. Registry ID: not stated in the record. MeSH: Adenomatous Polyps · Biopsy · Colon · Colonoscopy · Colorectal Neoplasms · Humans · Intestinal Polyps · Models, Statistical · Narrow Band Imaging · Practice Guidelines as Topic · Predictive Value of Tests · Rectum · United States