SourceMed · Shelf #1014 in the ask interface

Mechanical versus manual chest compressions (PARAMEDIC, LINC)

Shelf #1014 · Emergency & first hours

Stamped: development phase, October–November 2026 — exact date not recorded.

Evidence published: 2014–2015.

Last source check: 2026-11-15.

Source correction status: no correction or retraction found at the last source check (2026-11-15).

Question

Does a mechanical piston compression device improve survival or neurological outcome versus high-quality manual CPR in out-of-hospital cardiac arrest?

Balance of the evidence

LIKELY (the treatment made no difference) (Tier C: survival was the primary outcome in both trials, and both were null). PARAMEDIC (4,471 patients, LUCAS-2 vs manual CPR) found 30-day survival of 6% vs 7% (adjusted odds ratio 0.86, 95% CI 0.64–1.15). LINC (2,589 patients, mechanical compressions with simultaneous defibrillation vs guideline manual CPR) found 4-hour survival of 23.6% vs 23.7% and no significant difference in survival with good neurological outcome at any point to 6 months (8.5% vs 7.6%). Two large concordant randomised nulls on survival carry LIKELY (the treatment made no difference): routine mechanical CPR does not improve survival over good manual CPR.

MeSH: Cardiopulmonary Resuscitation/methods · Cluster Analysis · Emergency Medical Services/methods · Emergency Medical Technicians · England · Heart Massage/methods · Out-of-Hospital Cardiac Arrest/therapy

Cards (3)

Card 1 — PARAMEDIC (Perkins 2015): LUCAS-2 mechanical CPR did not improve 30-day survival (6% vs 7%; adjusted odds ratio 0.86)

Study: Pragmatic, cluster-randomised, open-label trial (ambulance-station clusters, four UK ambulance services)

Population: 4,471 eligible adults with non-traumatic out-of-hospital cardiac arrest (1,652 assigned to LUCAS-2, 2,819 to manual CPR); only 985 (60%) of the LUCAS-2 group actually received mechanical compression. The abstract does not state mean age or sex mix.

Summary: PARAMEDIC 2015: LUCAS-2 mechanical CPR did not improve 30-day survival ( 6% vs 7% ; adjusted odds ratio 0.86).

Result: 30-day survival was 104 of 1,652 patients (6%) in the LUCAS-2 group vs 193 of 2,819 (7%) with manual CPR (adjusted odds ratio 0.86, 95% CI 0.64–1.15) — a relative measure inside the 0.5–2.0 caution band, with absolute rates beside it, and not significant. No serious adverse events were noted; seven clinical adverse events were reported in the LUCAS-2 group (chest bruising, lacerations, blood in the mouth) and 15 device incidents occurred. The authors conclude that widespread adoption of mechanical CPR devices for routine use does not improve survival.

Watch out: Pragmatic delivery diluted the contrast (40% of the device group never received the device), so the trial tests a deployment strategy; but that is the clinically relevant question for routine use, and its null agrees with LINC's cleaner delivery.

Source: Perkins GD et al. Mechanical versus manual chest compression for out-of-hospital cardiac arrest (PARAMEDIC): a pragmatic, cluster randomised controlled trial. Lancet. 2015;385(9972):947-955. PMID: 25467566. Registry ID: ISRCTN08233942, from the record's databank fields.

Estimate type: adjusted estimate, as stated in the card.

Card 2 — LINC (Rubertsson 2014): mechanical compressions with simultaneous defibrillation matched manual CPR on 4-hour survival (23.6% vs 23.7%) and on good-outcome survival to 6 months

Study: Multicentre randomised clinical trial (six ambulance services in Sweden, the UK and the Netherlands)

Population: 2,589 patients with out-of-hospital cardiac arrest (1,300 mechanical CPR, 1,289 manual CPR), followed to 6 months. The abstract does not state mean age or sex mix.

Summary: LINC 2014: mechanical compressions matched manual CPR on 4-hour survival ( 23.6% vs 23.7% ) and on good-outcome survival.

Result: Four-hour survival was achieved by 307 patients (23.6%) with mechanical CPR and 305 (23.7%) with manual CPR (risk difference −0.05%, 95% CI −3.3% to 3.2%; P>.99). Survival with a good neurological outcome (CPC 1–2) did not differ significantly at ICU discharge (7.5% vs 6.4%), hospital discharge (8.3% vs 7.8%), 1 month (8.1% vs 7.3%) or 6 months (8.5% vs 7.6%). Among 6-month survivors, 99% in the mechanical group and 94% in the manual group had CPC scores of 1 or 2.

Watch out: LINC tested a specific algorithm (LUCAS compressions plus defibrillation during ongoing compressions), not a device alone; niche uses — transport, cath-lab CPR, prolonged resuscitation — were not the trial's question and are not answered by its null.

Source: Rubertsson S et al. Mechanical chest compressions and simultaneous defibrillation vs conventional cardiopulmonary resuscitation in out-of-hospital cardiac arrest: the LINC randomized trial. JAMA. 2014;311(1):53-61. PMID: 24240611. Registry ID: ClinicalTrials.gov NCT00609778, from the record's databank fields.

Card 3 — Synthesis: two large trials, one answer — mechanical CPR does not beat good manual CPR on survival; LIKELY (the treatment made no difference), Tier C

Study: Synthesis

Population: Synthesis of the cards above: PARAMEDIC (4,471 patients) and LINC (2,589 patients) — over 7,000 randomised patients between them.

Summary: Two large trials, one answer — mechanical CPR does not beat good manual CPR on survival — LIKELY the null, Tier C,.

Result: Survival was the primary outcome in both trials and was null in both: 30-day survival 6% vs 7% (PARAMEDIC) and 4-hour survival 23.6% vs 23.7% with good-outcome survival to 6 months of 8.5% vs 7.6% (LINC). That is the pattern the LIKELY (the treatment made no difference) stamp exists for. Nothing in the 2024–2026 currency sweep disturbs the pair.

Watch out: The null covers routine use for survival. It does not rule on mechanical CPR where manual CPR is impossible or unsafe (moving vehicles, few rescuers, catheterisation during CPR).

Source: Synthesis of Perkins GD et al. Lancet. 2015;385(9972):947-955. PMID: 25467566; Rubertsson S et al. JAMA. 2014;311(1):53-61. PMID: 24240611. Registry IDs as on the individual cards.