SourceMed · Shelf #10203 in the ask interface

Central iliac arteriovenous coupler for uncontrolled hypertension: office systolic pressure fell about 27 mm Hg at 6 months, but a third of recipients developed venous stenosis (ROX CONTROL HTN)

Shelf #10203 · Heart, vessels, blood pressure & clotting

POSSIBLE

Stamped: 2026-11-28.

Evidence published: 1979–2015.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In adults with uncontrolled hypertension despite medication, does implanting a central iliac arteriovenous anastomosis (coupler device) lower blood pressure compared with continuing medication alone?

Balance of the evidence

POSSIBLE — One open-label randomised trial of 83 patients, with a one-year follow-up report of the same trial; no second trial exists. Diagnosis first: the closest live shelves ask different hypertension questions — live #160 asks whether renal denervation lowers blood pressure beyond a sham procedure, and live #1100 asks whether the drug aprocitentan lowers pressure in resistant hypertension; neither creates an arteriovenous shunt or tests a permanent implant. The blood-pressure falls are large and were confirmed on ambulatory monitoring, but the trial was open-label, office readings are vulnerable to bias in that design, and the device caused ipsilateral venous stenosis in about a third of recipients, needing venoplasty or stenting. The tested device is named as published (the arteriovenous coupler device from ROX Medical) under the tested-product clarification exception. POSSIBLE: a coupler shunt lowered pressure substantially for at least a year in one small open-label trial, at the cost of frequent venous stenosis; it is an adjunct signal, not an established therapy.

MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Anastomosis, Surgical · Arteriovenous Shunt, Surgical · Female · Humans · Hypertension · Iliac Artery · Iliac Vein · Intention to Treat Analysis · Male · Middle Aged · Treatment Outcome · Young Adult

Cards (2)

Card 1 — ROX CONTROL HTN (Lobo 2015): office systolic pressure fell 26.9 mm Hg on the coupler versus 3.7 mm Hg on usual care at 6 months; venous stenosis in 12 of 42 recipients

Study: Randomised controlled trial, N = 83

Population: 83 patients with uncontrolled hypertension (office systolic at least 140 mm Hg and daytime ambulatory at least 135/85 mm Hg despite treatment), randomised to the arteriovenous coupler plus medication (n=44) or medication alone (n=39).

Summary: ROX CONTROL HTN (Lobo 2015): office systolic pressure fell 26.9 mm Hg on the coupler versus 3.7 mm Hg on usual care at 6 months; venous stenosis in 12 of 42 recipients

Result: Mean office systolic blood pressure fell by 26.9 mm Hg in the coupler group (p<0.0001) and by 3.7 mm Hg in controls (p=0.31); mean 24-hour ambulatory systolic pressure fell by 13.5 mm Hg versus 0.5 mm Hg. Late ipsilateral venous stenosis occurred in 12 (29%) of 42 coupler patients and was treatable with venoplasty or stenting.

Watch out: Open-label with no sham procedure, so expectation and measurement bias can inflate office readings; the ambulatory fall (13.5 mm Hg) is the more credible figure. Only 83 of 195 screened patients were randomised.

Source: Lobo MD, Sobotka PA, Stanton A, et al. Central arteriovenous anastomosis for the treatment of patients with uncontrolled hypertension (the ROX CONTROL HTN study): a randomised controlled trial. Lancet (London, England). 2015. PMID: 25620016. Registry ID: NCT01642498 (stated in the record). MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Anastomosis, Surgical · Arteriovenous Shunt, Surgical · Female · Humans · Hypertension · Iliac Artery · Iliac Vein · Intention to Treat Analysis · Male · Middle Aged · Treatment Outcome · Young Adult

Card 2 — One-year follow-up of the same trial (Lobo 2017): the fall persisted — office systolic down 25.1 mm Hg — and venous stenosis had reached 14 patients (33%), all stented successfully

Study: Randomised trial follow-up report, N = 39 coupler patients at 12 months

Population: 39 coupler patients in the intention-to-treat analysis at 12 months, from the same ROX CONTROL HTN trial as the first card — a follow-up report, not a second trial.

Summary: One-year follow-up of the same trial (Lobo 2017): the fall persisted — office systolic down 25.1 mm Hg — and venous stenosis had reached 14 patients (33%), all stented successfully

Result: Office systolic pressure was down 25.1 mm Hg and diastolic down 20.8 mm Hg at 12 months (both p<0.0001); mean 24-hour ambulatory pressure fell by 12.6/15.3 mm Hg. Fourteen patients (33%) developed ipsilateral venous stenosis; all were treated successfully with venous stenting.

Watch out: Same patients as the first card — the two reports are one trial, so the evidence base stays at 83 randomised patients. A permanent shunt also carries long-term questions (high-output cardiac load) that one year cannot answer.

Source: Lobo MD, Ott C, Sobotka PA, et al. Central Iliac Arteriovenous Anastomosis for Uncontrolled Hypertension: One-Year Results From the ROX CONTROL HTN Trial. Hypertension (Dallas, Tex. : 1979). 2017. PMID: 29061728. Registry ID: NCT01642498 (stated in the record). MeSH: Adolescent · Adult · Aged · Aged, 80 and over · Arteriovenous Shunt, Surgical · Blood Pressure · Blood Pressure Monitoring, Ambulatory · Female · Humans · Hypertension · Iliac Artery · Iliac Vein · Male · Middle Aged · Prospective Studies · Treatment Outcome · Young Adult