SourceMed · Shelf #10236 in the ask interface

Diaphragm excursion on M-mode ultrasound in healthy adults: lower limits near 1 cm in quiet breathing and 3.2–4.7 cm on deep breathing, larger in men, with deep-breathing repeatability reaching the 0.90 ideal within one observer

Shelf #10236 · Lungs, breathing & sleep

PHYSIOLOGY — ESTABLISHED

Stamped: 2026-11-28.

Evidence published: 2009–2021.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In healthy adults, how far does the diaphragm move on M-mode ultrasound during quiet breathing, sniffing and deep breathing — what are the lower limits of normal by sex and side — and how repeatable is the measurement?

Balance of the evidence

PHYSIOLOGY — ESTABLISHED — Composition: 4 healthy-volunteer studies, documented N = 790 (210 + 410 + 70 + 100), well above the 30 minimum. Two independent normative programmes (210 and 410 volunteers) give closely agreeing lower limits, and a standardised-protocol study adds thickness and thickening values. Reliability is explained in plain words where it arises: a reliability coefficient of 0.70 suffices for comparing groups, and 0.90 is the ideal — a measure is acceptable for individual-patient decisions when it reaches the 90% threshold; on that scale the deep-breathing measurement reaches the ideal within one observer (0.900) but quiet-breathing agreement between observers (0.632) does not reach even the group-comparison level, which is stated on its card. Excursions are distances in centimetres, stated neutrally; men move the diaphragm further than women in every study. PHYSIOLOGY — ESTABLISHED: healthy diaphragm excursion has reproducible sex-specific lower limits near 1 cm (quiet), 1.6–1.8 cm (sniff) and 3.2–4.7 cm (deep breathing).

MeSH: Adult · Aged · Anthropometry · Cohort Studies · Diaphragm · Echocardiography · Female · Functional Residual Capacity · Healthy Volunteers · Humans · Inhalation · Male · Maximal Respiratory Pressures · Middle Aged · Muscle Strength · Observer Variation · Probability · Prospective Studies · Reference Values · Reproducibility of Results · Respiratory Mechanics · Respiratory Muscles · Sensitivity and Specificity · Spirometry · Total Lung Capacity · Ultrasonography · Ultrasonography, Doppler · Young Adult

Cards (4)

Card 1 — Lower limits of normal excursion: 0.9 cm (women) and 1.0 cm (men) in quiet breathing, 1.6/1.8 cm on sniffing, 3.7/4.7 cm on deep breathing (Boussuges 2009)

Study: Healthy-volunteer normative study, N = 210

Population: 210 healthy adults (150 men, 60 women); both hemidiaphragms recorded by M-mode ultrasonography during quiet breathing, voluntary sniffing and deep breathing, with inter- and intra-observer reproducibility assessed.

Summary: Lower limits of normal excursion: 0.9 cm (women) and 1.0 cm (men) in quiet breathing, 1.6/1.8 cm on sniffing, 3.7/4.7 cm on deep breathing (Boussuges 2009)

Result: Right and left diaphragm motion could be measured in all subjects during quiet breathing and (on the left, in 208 of 210) during sniffing; during deep breathing the descending lung obscured the diaphragm in some subjects, so right excursion was measurable in 195 of 210 and left in only 45. Excursions were larger in men than women. The lower limit values were close to 0.9 cm for women and 1 cm for men during quiet breathing, 1.6 cm for women and 1.8 cm for men during voluntary sniffing, and 3.7 cm for women and 4.7 cm for men during deep breathing.

Watch out: Left-sided deep-breathing values rest on only 45 of the 210 volunteers because the lung obscures the left hemidiaphragm — the left deep-breathing limit is the thinnest number in this study.

Source: Boussuges A et al.. Diaphragmatic motion studied by m-mode ultrasonography: methods, reproducibility, and normal values. Chest. 2009. PMID: 19017880. Registry ID: not stated in the record. MeSH: Adult · Aged · Anthropometry · Cohort Studies · Diaphragm · Echocardiography · Female · Humans · Inhalation · Male · Middle Aged · Observer Variation · Probability · Reference Values · Reproducibility of Results · Respiratory Mechanics · Sensitivity and Specificity · Ultrasonography, Doppler · Young Adult

Card 2 — Second normative series (410 volunteers): deep-breathing lower limits 3.3 cm right / 3.2 cm left in women and 4.1 / 4.2 cm in men (Boussuges 2021)

Study: Healthy-volunteer normative study, N = 410

Population: 410 healthy volunteers (270 men, 140 women) studied seated; diaphragm excursion by M-mode ultrasonography with anatomical M-mode used to capture the full excursion during deep breathing.

Summary: Second normative series (410 volunteers): deep-breathing lower limits 3.3 cm right / 3.2 cm left in women and 4.1 / 4.2 cm in men (Boussuges 2021)

Result: Diaphragmatic motion during quiet breathing and voluntary sniffing was recorded in all participants, and excursions were larger in men than in women for both hemidiaphragms and all three manoeuvres. The lower limits of normal excursion during deep breathing were 3.3 cm (right) and 3.2 cm (left) in women and 4.1 cm (right) and 4.2 cm (left) in men; the authors propose these deep-breathing lower limits for detecting diaphragmatic hypokinesia.

Watch out: Same senior programme as the 2009 study on this shelf — the two series are confirmatory but not fully independent, which the ESTABLISHED grade takes into account and still accepts given the combined 620 volunteers.

Source: Boussuges A et al.. Diaphragmatic motion recorded by M-mode ultrasonography: limits of normality. ERJ open research. 2021. PMID: 33778044. Registry ID: not stated in the record. MeSH: none in the record

Card 3 — Standardised protocol: tidal-breathing excursion lower limit 1.2 cm in both sexes; diaphragm thickness lower limit 0.17 cm (men) / 0.15 cm (women) at functional residual capacity; thickening ratio lower limit 2.2 (Spiesshoefer 2020)

Study: Healthy-volunteer protocol study, N = 70

Population: 70 healthy adults (25 men, 45 women; age 34 ± 13 years) undergoing spirometry, maximal inspiratory and expiratory pressures, diaphragm ultrasound (excursion and thickness at tidal breathing, deep breathing and maximal sniff) and invasive transdiaphragmatic pressure measurement.

Summary: Standardised protocol: tidal-breathing excursion lower limit 1.2 cm in both sexes; diaphragm thickness lower limit 0.17 cm (men) / 0.15 cm (women) at functional residual capacity; thickening ratio lower limit 2.2 (Spiesshoefer 2020)

Result: Lower limits of normal (5th percentile) for excursion amplitude were 1.2 cm in both sexes during tidal breathing, 2.0 cm (men) and 1.5 cm (women) on maximal voluntary sniff, and 7.9 cm (men) and 6.4 cm (women) at total lung capacity. Lower limits for diaphragm thickness were 0.17 cm (men) and 0.15 cm (women) at functional residual capacity and 0.46 cm (men) and 0.35 cm (women) at total lung capacity; the lower limit for the thickening ratio was 2.2 with no sex difference. Volitional transdiaphragmatic pressure correlated only weakly with ultrasound excursion.

Watch out: A single-centre protocol study; its total-lung-capacity excursion is a coached maximal manoeuvre and is not comparable with the deep-breathing values in the other cards.

Source: Spiesshoefer J et al.. Evaluation of Respiratory Muscle Strength and Diaphragm Ultrasound: Normative Values, Theoretical Considerations, and Practical Recommendations. Respiration; international review of thoracic diseases. 2020. PMID: 32396905. Registry ID: not stated in the record. MeSH: Adult · Diaphragm · Female · Functional Residual Capacity · Healthy Volunteers · Humans · Male · Maximal Respiratory Pressures · Middle Aged · Muscle Strength · Reference Values · Respiratory Muscles · Spirometry · Total Lung Capacity · Ultrasonography · Young Adult

Card 4 — Repeatability: within one observer the intraclass correlation was 0.797 (quiet) and 0.900 (deep breathing); between observers 0.632 and 0.778 (Scarlata 2018)

Study: Healthy-volunteer reproducibility study, N = 100

Population: 100 healthy volunteers; supine right-dome diaphragm motion by M-mode ultrasound, three consecutive measurements per session for intra-observer agreement and repeat sessions by two experienced operators in 42 volunteers for inter-observer agreement.

Summary: Repeatability: within one observer the intraclass correlation was 0.797 (quiet) and 0.900 (deep breathing); between observers 0.632 and 0.778 (Scarlata 2018)

Result: Intra-observer agreement was 0.797 for quiet breathing and 0.900 for deep breathing (intraclass correlation); inter-observer agreement was 0.632 for quiet and 0.778 for deep breathing. Explained in plain words: 0.70 suffices for comparing groups, and 0.90 is the ideal — a measure is acceptable for individual-patient decisions when it reaches the 90% threshold. On that scale, deep breathing within one observer (0.900) reaches the ideal, deep breathing between observers (0.778) and quiet breathing within one observer (0.797) suffice for group comparisons, and quiet breathing between observers (0.632) reaches neither level. Excursion correlated positively with height and weight and, for deep breathing, negatively with age.

Watch out: Right dome only, supine only — these agreement figures do not cover the left hemidiaphragm or the seated position used in the normative studies.

Source: Scarlata S et al.. Reproducibility and Clinical Correlates of Supine Diaphragmatic Motion Measured by M-Mode Ultrasonography in Healthy Volunteers. Respiration; international review of thoracic diseases. 2018. PMID: 30114702. Registry ID: not stated in the record. MeSH: Adult · Diaphragm · Female · Healthy Volunteers · Humans · Male · Middle Aged · Prospective Studies · Reference Values · Reproducibility of Results · Ultrasonography