SourceMed · Shelf #10242 in the ask interface
Adding copeptin to troponin for early myocardial infarction rule-out: sensitivity rises (0.87 to 0.96 in the largest synthesis) but specificity falls to about 0.50–0.57 — the gain is bought with false positives
Shelf #10242 · Heart, vessels, blood pressure & clotting
MEASUREMENT ACCURACY — PARTIAL
Stamped: 2026-11-28.
Evidence published: 2011–2014.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In emergency-department patients with suspected acute myocardial infarction, how accurately does adding copeptin to cardiac troponin on presentation rule out myocardial infarction, compared with troponin alone — what sensitivity is gained and what specificity is paid?
Balance of the evidence
MEASUREMENT ACCURACY — PARTIAL — Composition: 2 meta-analyses with overlapping pools (15 studies / 8,740 patients; 14 studies / 9,244 patients) and 1 prospective primary study (503 patients) — the syntheses are counted as syntheses, never as independent confirmations. Sensitivity and specificity are labelled in words at first occurrence in each card. Diagnosis first: myocardial infarction was defined by the universal definition with troponin as the necrosis marker, which structurally favours the troponin-containing strategies. Every record agrees on the trade: adding copeptin raises sensitivity by roughly 9–22 points and raises the negative predictive value, while specificity falls to about one half — so the strategy discharges more true negatives correctly only by also flagging many more false positives. That one-sided trade, consistent across all three records, is the PARTIAL grade. Copeptin and the troponin assays are named as published. MEASUREMENT ACCURACY — PARTIAL: copeptin plus troponin is a sensitive rule-out (sensitivity 0.95–0.98, negative predictive value up to 99%) at a specificity near 0.50–0.57 that no record shows can be avoided.
MeSH: Aged · Biomarkers · Chest Pain · Diagnosis, Differential · Female · Glycopeptides · Humans · Male · Middle Aged · Myocardial Infarction · Predictive Value of Tests · Prospective Studies · Protein Precursors · ROC Curve · Troponin I · Troponin T
Cards (3)
Card 1 — Meta-analysis of 15 studies (8,740 patients): adding copeptin raised troponin's sensitivity from 0.87 to 0.96 while specificity fell from 0.84 to 0.56 (Raskovalova 2014)
Study: Systematic review and meta-analysis, 15 studies / 8,740 patients
Population: 15 primary studies of patients with symptoms suggestive of acute myocardial infarction (AMI prevalence 16%); myocardial infarction defined by the universal definition using cardiac troponin as the necrosis marker.
Summary: Meta-analysis of 15 studies (8,740 patients): adding copeptin raised troponin's sensitivity from 0.87 to 0.96 while specificity fell from 0.84 to 0.56 (Raskovalova 2014)
Result: Sensitivity and specificity are labelled in words here at first occurrence. Adding copeptin to cardiac troponin improved sensitivity from 0.87 to 0.96 (p = 0.003) at the expense of specificity, which fell from 0.84 to 0.56 (p < 0.001). In the 12 studies of patients without ST-segment elevation (6,988 patients), the combined assessment gave summary sensitivity 0.95 (95% CI 0.89 to 0.98) and specificity 0.57 (95% CI 0.49 to 0.65). With a high-sensitivity troponin T assay the combination gave sensitivity 0.98 (95% CI 0.96 to 1.00) and specificity 0.50 (95% CI 0.42 to 0.58). The authors note substantial between-study heterogeneity and call for management studies.
Watch out: Because troponin is part of the reference definition of myocardial infarction, troponin-based strategies are graded partly against themselves; the sensitivity gain for the combination is nonetheless measured against that same standard.
Source: Raskovalova T et al.. Diagnostic accuracy of combined cardiac troponin and copeptin assessment for early rule-out of myocardial infarction: a systematic review and meta-analysis. European heart journal. Acute cardiovascular care. 2014. PMID: 24562800. Registry ID: not stated in the record. MeSH: Biomarkers · Diagnosis, Differential · Glycopeptides · Humans · Myocardial Infarction · Predictive Value of Tests · Protein Precursors · ROC Curve · Troponin I · Troponin T
Card 2 — Collaborative meta-analysis (14 studies, 9,244 patients): the combination's sensitivity was 0.905 against troponin alone at 0.686, and negative predictive value 0.97 against 0.93 (Lipinski 2014)
Study: Collaborative meta-analysis, 14 studies / 9,244 patients
Population: 9,244 emergency-department patients with chest pain from 14 studies (mean age 62 years, 64% men, 18.4% ultimately diagnosed with acute myocardial infarction); study investigators contributed previously unpublished data.
Summary: Collaborative meta-analysis (14 studies, 9,244 patients): the combination's sensitivity was 0.905 against troponin alone at 0.686, and negative predictive value 0.97 against 0.93 (Lipinski 2014)
Result: Sensitivity and specificity are labelled in words here at first occurrence. Presentation copeptin concentration was higher in patients with myocardial infarction than without (22.8 versus 8.3 pmol/L, p < 0.001). Troponin alone had sensitivity 0.686 (95% CI 0.661 to 0.710) and negative predictive value 0.93; adding copeptin raised sensitivity to 0.905 (95% CI 0.888 to 0.921) and negative predictive value to 0.97 (both p < 0.001), while troponin retained better overall diagnostic accuracy than copeptin alone. An elevated copeptin carried a mortality risk similar to an elevated troponin (odds ratio 5.84 versus 6.74).
Watch out: This pool overlaps the Raskovalova pool on this shelf; the two syntheses are one literature read twice, not two literatures.
Source: Lipinski MJ et al.. A systematic review and collaborative meta-analysis to determine the incremental value of copeptin for rapid rule-out of acute myocardial infarction. The American journal of cardiology. 2014. PMID: 24731654. Registry ID: not stated in the record. MeSH: Biomarkers · Female · Glycopeptides · Humans · Male · Middle Aged · Myocardial Infarction
Card 3 — Prospective primary study (503 patients): hs-cTnT below 14 ng/L plus copeptin below 14 pmol/L gave sensitivity 97.7% and negative predictive value 99.03% for non-STEMI — at specificity 55.9% (Giannitsis 2011)
Study: Prospective diagnostic accuracy study, N = 503
Population: 503 patients with suspected acute coronary syndrome and chest-pain onset within the previous 12 hours; copeptin measured on presentation and high-sensitivity cardiac troponin T serially at baseline, 3 and 6 hours (assays named as published).
Summary: Prospective primary study (503 patients): hs-cTnT below 14 ng/L plus copeptin below 14 pmol/L gave sensitivity 97.7% and negative predictive value 99.03% for non-STEMI — at specificity 55.9% (Giannitsis 2011)
Result: Sensitivity and specificity are labelled in words here at first occurrence. For ruling out non-ST-elevation myocardial infarction at the prespecified cut-offs (high-sensitivity troponin T <14 ng/L, the 99th percentile, plus copeptin <14 pmol/L), sensitivity was 97.7% (95% CI 91.9 to 99.7), negative predictive value 99.03% (95% CI 96.6 to 99.9), specificity 55.9% (95% CI 50.6 to 61.0) and positive predictive value 34.4% (95% CI 28.5 to 40.7). The authors also report that receiver-operating-curve analysis of the continuous values showed no added value of the combination — the benefit exists only at the prespecified rule-out cut-offs.
Watch out: Single study, and its own continuous-value analysis contradicts a general added value — the strategy works, if at all, only as a fixed dual cut-off rule-out.
Source: Giannitsis E et al.. Combined testing of high-sensitivity troponin T and copeptin on presentation at prespecified cutoffs improves rapid rule-out of non-ST-segment elevation myocardial infarction. Clinical chemistry. 2011. PMID: 21807867. Registry ID: not stated in the record. MeSH: Aged · Chest Pain · Female · Glycopeptides · Humans · Male · Middle Aged · Myocardial Infarction · Predictive Value of Tests · Prospective Studies · Troponin T