SourceMed · Shelf #10258 in the ask interface

Dynamic position changes during colonoscope withdrawal: adenoma detection 42.4% versus 33.0% in a 1,072-patient multicentre trial, and a 5-trial synthesis found the same direction (odds ratio 1.34)

Shelf #10258 · Liver & gut

POSSIBLE

Stamped: 2026-11-28.

Evidence published: 2016–2021.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In adults undergoing colonoscopy, do dynamic position changes during withdrawal (turning the patient segment by segment) increase adenoma detection versus keeping the patient in the left lateral position throughout?

Balance of the evidence

POSSIBLE — One multicentre randomised trial (1,072 patients) and a meta-analysis of 5 randomised trials agree that turning patients during withdrawal raises adenoma detection, with the gain concentrated in the transverse and left colon and in endoscopists with lower baseline detection. The manoeuvre costs no significant extra withdrawal time in the pooled record. Detection is a surrogate: no record here shows fewer cancers. POSSIBLE: segment-by-segment position change during withdrawal improves adenoma detection, most where baseline detection is weakest.

MeSH: Adenoma · Aged · Aged, 80 and over · Colonoscopes · Colonoscopy · Colorectal Neoplasms · Cross-Over Studies · Device Removal · Female · Humans · Male · Middle Aged · Patient Positioning · Prospective Studies · Colon, Transverse · Colonic Polyps · Odds Ratio · Randomized Controlled Trials as Topic

Cards (2)

Card 1 — Lee 2016 (1,072 patients, 6 hospitals): adenoma detection 42.4% with position changes versus 33.0% staying left-lateral (P = 0.002); 0.90 versus 0.67 adenomas per patient

Study: Multicentre randomised controlled trial, N = 1,072

Population: 1,072 patients aged 45–80 undergoing first colonoscopy at six Korean hospitals, randomised to dynamic position change during withdrawal (left lateral for the right colon, supine for the transverse colon, right lateral for the left colon; n = 536) or left lateral throughout (n = 536).

Summary: Lee 2016 (1,072 patients, 6 hospitals): adenoma detection 42.4% with position changes versus 33.0% staying left-lateral (P = 0.002); 0.90 versus 0.67 adenomas per patient

Result: Adenoma detection rate was 42.4% in the position-change group versus 33.0% in the control group (P = 0.002), with more adenomas per subject (0.90 versus 0.67; P = 0.01). Gains were seen in the transverse colon (0.22 versus 0.13 adenomas; P = 0.016) and left colon (0.37 versus 0.27; P = 0.045). The detection gain was significant for endoscopists with relatively low baseline detection and not significant for high detectors.

Watch out: Endoscopists cannot be blinded to patient position, and first-colonoscopy patients at Korean centres may not match screening populations elsewhere.

Source: Lee SW et al.. Effect of Dynamic Position Changes on Adenoma Detection During Colonoscope Withdrawal: A Randomized Controlled Multicenter Trial. The American journal of gastroenterology. 2016. PMID: 26526085. Registry ID: not stated in the record. MeSH: Adenoma · Aged · Aged, 80 and over · Colonoscopes · Colonoscopy · Colorectal Neoplasms · Cross-Over Studies · Device Removal · Female · Humans · Male · Middle Aged · Patient Positioning · Prospective Studies

Card 2 — Li 2021 meta-analysis (5 RCTs): total adenoma detection higher with dynamic position change (odds ratio 1.34, 95% CI 1.13 to 1.59); polyp detection not significantly different; withdrawal time not significantly longer (+0.47 minutes)

Study: Meta-analysis of randomised trials, 5 RCTs

Population: 5 randomised controlled trials of dynamic position changes during colonoscope withdrawal (the record does not state a pooled patient total in its abstract).

Summary: Li 2021 meta-analysis (5 RCTs): total adenoma detection higher with dynamic position change (odds ratio 1.34, 95% CI 1.13 to 1.59); polyp detection not significantly different; withdrawal time not significantly longer (+0.47 minutes)

Result: Total adenoma detection rate was higher with position change (odds ratio 1.34, 95% CI 1.13 to 1.59; P < 0.001, no heterogeneity), while total polyp detection was not significantly different (odds ratio 1.23, 95% CI 0.88 to 1.73). Withdrawal time rose by 0.47 minutes (95% CI −0.11 to 1.06; not significant). In the transverse colon, both adenoma detection (odds ratio 1.72) and polyp detection (odds ratio 1.79) were significantly higher.

Watch out: The pool includes the Lee trial carded above; the abstract reports no pooled patient total, so none is claimed here.

Source: Li P et al.. Effect of dynamic position changes during colonoscope withdrawal: a meta-analysis of randomized controlled trials. Surgical endoscopy. 2021. PMID: 32128607. Registry ID: not stated in the record. MeSH: Adenoma · Colon, Transverse · Colonic Polyps · Colonoscopes · Colonoscopy · Colorectal Neoplasms · Humans · Male · Middle Aged · Odds Ratio · Randomized Controlled Trials as Topic