SourceMed · Shelf #10306 in the ask interface

Anti-PLA2R antibody: a positive serum test almost settles idiopathic membranous nephropathy (specificity 0.97–0.99), but sensitivity near 0.68 means a negative test rules nothing out

Shelf #10306 · Kidney, fluids & electrolytes

MEASUREMENT ACCURACY — PARTIAL

Stamped: 2026-11-28.

Evidence published: 2014–2015.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with membranous nephropathy, how accurately do serum anti-PLA2R autoantibodies — and glomerular PLA2R staining on biopsy — distinguish idiopathic (primary) from secondary membranous nephropathy: what are their sensitivity and specificity, labelled in words?

Balance of the evidence

MEASUREMENT ACCURACY — PARTIAL — Composition: 2 diagnostic accuracy meta-analyses (19 studies / 1,160 patients; 10 studies / 1,550 participants), overlapping in primary studies and counted as syntheses. Diagnosis first: the population is patients who already have membranous nephropathy on biopsy, and the question is classification — idiopathic versus secondary — not detection of the disease. Sensitivity and specificity are labelled in words at first occurrence on every card. The pattern is one-sided and consistent across both syntheses: serum anti-PLA2R is highly specific (specificity 0.97–0.99) but only moderately sensitive (sensitivity 0.68–0.69; 0.74 in active disease), so a positive result rules idiopathic disease in and a negative result cannot rule it out — roughly a third of idiopathic cases are seronegative. Glomerular staining is a little more sensitive (sensitivity 0.78) and a little less specific (specificity 0.91). Heterogeneity for the serum test was substantial (I² = 86%). MEASUREMENT ACCURACY — PARTIAL: anti-PLA2R is a rule-in test for idiopathic membranous nephropathy, not a rule-out test.

MeSH: Autoantibodies · Biopsy · Diagnosis, Differential · Glomerulonephritis, Membranous · Humans · Immunosuppressive Agents · Kidney Glomerulus · Proteinuria · ROC Curve · Receptors, Phospholipase A2 · Reproducibility of Results · Sensitivity and Specificity

Cards (2)

Card 1 — Meta-analysis (19 studies, 1,160 patients): serum anti-PLA2R sensitivity 0.68 and specificity 0.97 for idiopathic versus secondary membranous nephropathy (Dai 2015)

Study: Diagnostic accuracy meta-analysis, 19 studies / 1,160 patients

Population: 19 diagnostic studies involving 1,160 patients with membranous nephropathy, testing serum anti-PLA2R autoantibodies and glomerular PLA2R staining against the clinical classification of idiopathic versus secondary membranous nephropathy. Diagnosis first: every patient already had membranous nephropathy — the test question is which kind, not whether the disease is present.

Summary: Meta-analysis (19 studies, 1,160 patients): serum anti-PLA2R sensitivity 0.68 and specificity 0.97 for idiopathic versus secondary membranous nephropathy (Dai 2015)

Result: Sensitivity and specificity are labelled in words here at first occurrence. For serum anti-PLA2R: sensitivity 0.68 (95% CI 0.61 to 0.74) and specificity 0.97 (95% CI 0.85 to 1.00), diagnostic odds ratio 73.75, area under the ROC curve 0.82 — with substantial heterogeneity (I² = 86.42%). For glomerular PLA2R staining on biopsy: sensitivity 0.78 (95% CI 0.72 to 0.83) and specificity 0.91 (95% CI 0.75 to 0.97), diagnostic odds ratio 34.70, area under the curve 0.84, without heterogeneity (I² = 0%). The authors conclude the serum test has diagnostic value but must be read with the clinical picture, and that staining is recommended in seronegative patients.

Watch out: Heterogeneity for the serum test was substantial, and study design, assay method and origin all contributed — a single pooled sensitivity hides real between-laboratory variation.

Source: Dai H et al. Diagnostic accuracy of PLA2R autoantibodies and glomerular staining for the differentiation of idiopathic and secondary membranous nephropathy: an updated meta-analysis. Scientific reports. 2015. PMID: 25740009. Registry ID: not stated in the record. MeSH: Autoantibodies · Biopsy · Diagnosis, Differential · Glomerulonephritis, Membranous · Humans · Immunosuppressive Agents · Kidney Glomerulus · Proteinuria · ROC Curve · Receptors, Phospholipase A2 · Reproducibility of Results · Sensitivity and Specificity

Card 2 — Earlier meta-analysis (10 studies, 1,550 participants): serum anti-PLA2R sensitivity 0.69 and specificity 0.99 overall; in active disease sensitivity 0.74 and specificity 0.95 (Hu 2014)

Study: Diagnostic accuracy meta-analysis, 10 studies / 1,550 participants

Population: 10 diagnostic studies involving 1,550 participants assessing serum anti-PLA2R levels and biopsy PLA2R staining for the diagnosis of idiopathic membranous nephropathy at different disease stages; study quality assessed with QUADAS-2.

Summary: Earlier meta-analysis (10 studies, 1,550 participants): serum anti-PLA2R sensitivity 0.69 and specificity 0.99 overall; in active disease sensitivity 0.74 and specificity 0.95 (Hu 2014)

Result: Sensitivity and specificity are labelled in words. Across all settings, serum anti-PLA2R gave sensitivity 0.69 and specificity 0.99 with a diagnostic odds ratio of 247.41. Restricted to active-stage disease, sensitivity was 0.74 and specificity 0.95 (diagnostic odds ratio 54.22). Biopsy PLA2R staining gave sensitivity 0.73 and specificity 0.83 (diagnostic odds ratio 13.75). The authors call for large prospective cohorts to pin down serum antibody versus biopsy antigen at each disease stage.

Watch out: The two meta-analyses on this shelf overlap in their primary studies and are counted as syntheses, never as independent confirmations; both predate standardised commercial assays.

Source: Hu SL et al. Diagnostic value of phospholipase A2 receptor in idiopathic membranous nephropathy: a systematic review and meta-analysis. Journal of nephrology. 2014. PMID: 24500886. Registry ID: not stated in the record. MeSH: Antibodies · Biopsy · Glomerulonephritis, Membranous · Humans · Kidney · Receptors, Phospholipase A2 · Sensitivity and Specificity