Intraocular pressure peaks at night: a 24-hour swing of about 7 mm Hg in habitual position, of which posture explains roughly half — the rest is a true circadian rhythm
Shelf #10336 · Eyes, skin, nose & allergy
PHYSIOLOGY — ESTABLISHED
Stamped: 2026-11-28.
Evidence published: 1998–2016.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In healthy humans, how does intraocular pressure vary across the 24 hours — when are its trough and peak, how large is the swing, how much of the nocturnal rise is posture (lying down) rather than circadian rhythm, and does ageing change the pattern?
Balance of the evidence
PHYSIOLOGY — ESTABLISHED — Composition: 4 primary human studies (documented N = 275: 33 + 21 + 15 + 206; a fifth dataset of 16 younger volunteers inside the third study was previously collected and is not double-counted). All measurements are sleep-laboratory or population protocols with tonometry every 2 hours across a full day. The findings agree: intraocular pressure is lowest at the end of the waking day and highest in the dark/sleep period; in habitual position (sitting by day, supine by night) the peak–trough difference is about 7–9 mm Hg, and when posture is held supine throughout, a smaller rhythm of about 3–4 mm Hg remains — so the nocturnal elevation is part postural, part circadian. In the population study the cosine-fit peak fell at about 03:49, and ageing delayed the rhythm's phase without changing the postural effect. PHYSIOLOGY — ESTABLISHED: a nocturnal intraocular pressure peak is normal physiology, and a single daytime office reading systematically misses it.
MeSH: Adolescent · Adult · Circadian Rhythm · Female · Humans · Intraocular Pressure · Male · Posture · Tonometry, Ocular · Aged · Aging · Dark Adaptation · Middle Aged · Sleep · Supine Position · Time Factors · Young Adult · Blood Pressure · Healthy Volunteers · Heart Rate · Pilot Projects · Reference Values
Cards (4)
Card 1 — In 33 young adults the trough-to-peak IOP swing was 8.2 mm Hg in habitual position but 3.8 mm Hg when supine throughout — a circadian rhythm on top of a postural effect (Liu 1998)
Study: Primary human laboratory study, N = 33
Population: 33 healthy young adult volunteers housed in a sleep laboratory for 1 day under a controlled 16-hour light / 8-hour dark environment; IOP measured in each eye every 2 hours by pneumatonometer — in 12 subjects sitting by day and supine in the dark, and in 21 subjects supine throughout.
Summary: In 33 young adults the trough-to-peak IOP swing was 8.2 mm Hg in habitual position but 3.8 mm Hg when supine throughout — a circadian rhythm on top of a postural effect (Liu 1998)
Result: Average IOP was significantly higher in the dark period than the light–wake period in both groups; the lowest IOP occurred at the last light–wake measurement and the peak at the last dark measurement. The trough–peak difference was 8.2 ± 1.4 mm Hg in the habitual-position group and 3.8 ± 0.9 mm Hg in the always-supine group, and IOP changed gradually across the 24 hours when posture was fixed. The authors conclude a circadian rhythm of IOP exists in young adults with peaks in the late dark period, and that the posture change from upright to recumbent adds to the nocturnal elevation.
Watch out: Sleep-laboratory conditions with encouraged sleep and 2-hourly waking for measurement: the rhythm is real under these controlled conditions, and free-living amplitudes may differ.
Source: Liu JH, Kripke DF, Hoffman RE, Twa MD et al. Nocturnal elevation of intraocular pressure in young adults. Investigative ophthalmology & visual science. 1998. PMID: 9856781. Registry ID: not stated in the record. MeSH: Adolescent · Adult · Circadian Rhythm · Female · Humans · Intraocular Pressure · Male · Posture · Tonometry, Ocular
Card 2 — In 21 volunteers aged 50–69 the habitual-position swing was 8.6 mm Hg, the peak came at the start of the dark period, and posture was the main factor (Liu 1999)
Study: Primary human laboratory study, N = 21
Population: 21 healthy volunteers aged 50–69 years housed in a sleep laboratory for 24 hours (16-hour light, 8-hour dark), with pneumatonometer IOP measured every 2 hours — sitting and supine during the light period, supine only during the dark period.
Summary: In 21 volunteers aged 50–69 the habitual-position swing was 8.6 mm Hg, the peak came at the start of the dark period, and posture was the main factor (Liu 1999)
Result: Mean IOP in the dark period was significantly higher than in the light–wake period; the trough appeared at the end of the light–wake period and the peak at the beginning of the dark period, with a trough–peak difference of 8.6 ± 0.8 mm Hg in habitual position. Using supine-only data the difference was 3.4 ± 0.7 mm Hg and cosine fits showed no statistically significant 24-hour rhythm in that posture alone. The authors conclude the main factor in the nocturnal elevation in this age group was the shift from upright to supine posture.
Watch out: In this older sample the supine-only rhythm did not reach significance — the card states the authors' own reading (posture dominant) rather than merging it with the younger-adult result.
Source: Liu JH, Kripke DF, Twa MD, Hoffman RE et al. Twenty-four-hour pattern of intraocular pressure in the aging population. Investigative ophthalmology & visual science. 1999. PMID: 10549652. Registry ID: not stated in the record. MeSH: Aged · Aging · Circadian Rhythm · Dark Adaptation · Female · Humans · Intraocular Pressure · Male · Middle Aged · Posture · Sleep · Tonometry, Ocular
Card 3 — Ageing delayed the 24-hour IOP rhythm's phase toward the waking period but left the postural effect unchanged at about 4.7–4.8 mm Hg (Mansouri 2012)
Study: Primary human laboratory study, N = 15 (+16 previously collected comparison subjects)
Population: 15 older volunteers with healthy eyes (53–71 years) housed for 1 day in a sleep laboratory with IOP measured every 2 hours sitting and supine; their data were compared with previously collected data from 16 healthy younger subjects (18–25 years) under the same conditions (comparison dataset not counted in this pack's documented total).
Summary: Ageing delayed the 24-hour IOP rhythm's phase toward the waking period but left the postural effect unchanged at about 4.7–4.8 mm Hg (Mansouri 2012)
Result: Within each age group the sitting and supine 24-hour IOP patterns were similar and parallel. Compared with the younger subjects, the phase timing (simulated peak) of the 24-hour IOP rhythm was significantly delayed in the older subjects in both body positions. The postural IOP effect in the older subjects was 4.7 ± 0.8 mm Hg in the diurnal period and 4.8 ± 0.8 mm Hg in the nocturnal period, not significantly different from the younger subjects.
Watch out: Fifteen new subjects; the age comparison rests on a previously collected younger cohort from the same laboratory rather than a concurrently recruited control group.
Source: Mansouri K, Weinreb RN, Liu JH. Effects of aging on 24-hour intraocular pressure measurements in sitting and supine body positions. Investigative ophthalmology & visual science. 2012. PMID: 22159010. Registry ID: not stated in the record. MeSH: Adolescent · Adult · Aged · Aging · Circadian Rhythm · Female · Humans · Intraocular Pressure · Male · Middle Aged · Posture · Supine Position · Time Factors · Tonometry, Ocular · Young Adult
Card 4 — In 206 population-sampled healthy adults the habitual peak–trough difference was 7.2 mm Hg (95th percentile 11.5), with a cosine-fit peak at 03:49 and no age-group differences (Handan Eye Study 2016)
Study: Primary population study, N = 206
Population: 206 healthy subjects sampled from the population in the Handan Eye Study (20 aged 30–39, 95 aged 40–49, 91 aged 50–59 years), with IOP measured every 2 hours — seated during the light–wake period and supine during the dark–sleep period — alongside blood pressure and heart rate.
Summary: In 206 population-sampled healthy adults the habitual peak–trough difference was 7.2 mm Hg (95th percentile 11.5), with a cosine-fit peak at 03:49 and no age-group differences (Handan Eye Study 2016)
Result: The peak–trough difference in habitual position was 7.2 ± 2.3 mm Hg (95% CI 6.8 to 7.5), median 7.0 mm Hg, 25th percentile 5.5 mm Hg and 95th percentile 11.5 mm Hg; 75% of subjects had variation above 5.5 mm Hg. The cosine-fit acrophase was 03:49. By pattern, 52% had a nocturnal peak, 17% a diurnal peak and 31% no evident pattern. No significant differences in peak–trough difference, acrophase or amplitude were found among the three age groups.
Watch out: A third of these healthy subjects had no evident peak pattern: the rhythm is a population regularity with wide individual variation, not a clock every individual follows.
Source: Wang NL, Hao J, Zhen Y, Liu JH et al. A Population-based Investigation of Circadian Rhythm of Intraocular Pressure in Habitual Position Among Healthy Subjects: The Handan Eye Study. Journal of glaucoma. 2016. PMID: 26633310. Registry ID: not stated in the record. MeSH: Adult · Aging · Blood Pressure · Circadian Rhythm · Female · Healthy Volunteers · Heart Rate · Humans · Intraocular Pressure · Male · Middle Aged · Pilot Projects · Posture · Reference Values · Sleep · Tonometry, Ocular