Pacing mode in sick sinus syndrome and bradycardia: dual-chamber pacing did not reduce death versus single-lead atrial pacing in DANPACE (29.6% versus 27.3%) but halved reoperations, and physiologic pacing did not reduce stroke or cardiovascular death versus ventricular pacing in CTOPP
Shelf #10344 · Heart, vessels, blood pressure & clotting
SPLIT
Stamped: 2026-11-28.
Evidence published: 2000–2011.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients receiving a first pacemaker for sick sinus syndrome or symptomatic bradycardia, does atrial-based or dual-chamber (physiologic) pacing reduce death, stroke, atrial fibrillation and heart failure compared with single-lead atrial pacing or single-chamber ventricular pacing?
Balance of the evidence
SPLIT — Composition: 2 randomised trials (documented N = 3,983: 1,415 + 2,568). Diagnosis first: the two trials ask different halves of the mode question in overlapping but distinct populations — DANPACE compares two atrial-based modes (AAIR versus DDDR) in sick sinus syndrome, while CTOPP compares physiologic pacing (dual-chamber or atrial) against single-chamber ventricular pacing in first-implant bradycardia. On death and stroke the answer is consistently null: DANPACE mortality 29.6% versus 27.3% (hazard ratio 1.06; the treatment made no difference), and CTOPP's annual rate of stroke or cardiovascular death was 5.5% versus 4.9% (P = 0.33; the treatment made no difference). The split is in the secondary outcomes: AAIR caused more paroxysmal atrial fibrillation (28.4% versus 23.0%) and twice the reoperations (22.1% versus 11.9%) than DDDR, while physiologic pacing in CTOPP modestly lowered atrial fibrillation (annual 5.3% versus 6.6%, an 18.0% relative risk reduction) at the cost of more perioperative complications (9.0% versus 3.8%). SPLIT: no pacing mode prolongs life or prevents stroke in these trials; dual-chamber pacing is favoured over atrial-only pacing by fewer reoperations and less atrial fibrillation, and over ventricular-only pacing by less atrial fibrillation, balanced against more implant complications.
MeSH: Adolescent · Adult · Aged · Atrial Fibrillation · Bradycardia · Cardiac Pacing, Artificial · Cardiotonic Agents · Cardiovascular Diseases · Cause of Death · Female · Follow-Up Studies · Heart Block · Humans · Male · Middle Aged · Pacemaker, Artificial · Reoperation · Risk · Sick Sinus Syndrome · Stroke · Treatment Outcome · Young Adult
Cards (2)
Card 1 — DANPACE: AAIR versus DDDR in sick sinus syndrome — death 29.6% versus 27.3% (the treatment made no difference), but AAIR brought more paroxysmal atrial fibrillation and twice the pacemaker reoperations (Nielsen 2011)
Study: Primary randomised trial, N = 1,415
Population: 1,415 patients referred for first pacemaker implantation with sick sinus syndrome, randomly assigned to single-lead atrial pacing (AAIR, n = 707) or dual-chamber pacing (DDDR, n = 708), followed for a mean of 5.4 ± 2.6 years.
Summary: DANPACE: AAIR versus DDDR in sick sinus syndrome — death 29.6% versus 27.3% (the treatment made no difference), but AAIR brought more paroxysmal atrial fibrillation and twice the pacemaker reoperations (Nielsen 2011)
Result: Death from any cause occurred in 209 patients (29.6%) on AAIR versus 193 (27.3%) on DDDR (hazard ratio 1.06; 95% CI 0.88–1.29; P = 0.53). Paroxysmal atrial fibrillation was more frequent on AAIR (28.4% versus 23.0%; hazard ratio 1.27; 95% CI 1.03–1.56; P = 0.024), as were pacemaker reoperations (22.1% versus 11.9%; hazard ratio 1.99; 95% CI 1.53–2.59; P < 0.001). Chronic atrial fibrillation, stroke and heart failure did not differ between groups.
Watch out: A first-implant sick-sinus population from before modern minimised-ventricular-pacing algorithms and conduction-system pacing: the reoperation penalty of AAIR is the durable finding, while the atrial-fibrillation difference is a secondary outcome.
Source: Nielsen JC, Thomsen PE, Højberg S, Møller M, Vesterlund T, Dalsgaard D et al. A comparison of single-lead atrial pacing with dual-chamber pacing in sick sinus syndrome. European heart journal. 2011. PMID: 21300730. Registry ID: NCT00236158. MeSH: Adolescent · Adult · Aged · Atrial Fibrillation · Cardiac Pacing, Artificial · Cardiotonic Agents · Cause of Death · Female · Follow-Up Studies · Humans · Male · Middle Aged · Pacemaker, Artificial · Reoperation · Sick Sinus Syndrome · Stroke · Treatment Outcome · Young Adult
Card 2 — CTOPP: physiologic pacing did not reduce stroke or cardiovascular death versus ventricular pacing (annual 4.9% versus 5.5%, P = 0.33) but lowered atrial fibrillation, with more perioperative complications (Connolly 2000)
Study: Primary randomised trial, N = 2,568
Population: 2,568 patients without chronic atrial fibrillation scheduled for a first pacemaker for symptomatic bradycardia at 32 Canadian centres, randomly assigned to a ventricular pacemaker (n = 1,474) or a physiologic (dual-chamber or atrial) pacemaker (n = 1,094), followed for an average of 3 years.
Summary: CTOPP: physiologic pacing did not reduce stroke or cardiovascular death versus ventricular pacing (annual 4.9% versus 5.5%, P = 0.33) but lowered atrial fibrillation, with more perioperative complications (Connolly 2000)
Result: The annual rate of stroke or death from cardiovascular causes was 5.5% with ventricular pacing versus 4.9% with physiologic pacing (9.4% relative risk reduction; 95% CI −10.5 to 25.7; P = 0.33). Annual atrial fibrillation rates were lower with physiologic pacing (5.3% versus 6.6%; 18.0% relative risk reduction; 95% CI 0.3 to 32.6; P = 0.05), an effect not apparent until 2 years after implantation. All-cause death and heart-failure hospitalisation were lower but not significantly so, and perioperative complications were significantly more frequent with physiologic pacing (9.0% versus 3.8%; P < 0.001).
Watch out: A mixed bradycardia population (sinus-node disease and heart block) implanted in the 1990s: the atrial-fibrillation advantage emerged only after 2 years and the primary outcome was null, so this trial supports mode choice on rhythm and reoperation grounds, not survival.
Source: Connolly SJ, Kerr CR, Gent M, Roberts RS, Yusuf S, Gillis AM et al. Effects of physiologic pacing versus ventricular pacing on the risk of stroke and death due to cardiovascular causes. Canadian Trial of Physiologic Pacing Investigators. The New England journal of medicine. 2000. PMID: 10805823. Registry ID: not stated in the record. MeSH: Aged · Atrial Fibrillation · Bradycardia · Cardiac Pacing, Artificial · Cardiovascular Diseases · Female · Heart Block · Humans · Male · Pacemaker, Artificial · Risk · Stroke