SourceMed · Shelf #10484 in the ask interface

Blood pressure has its own endogenous circadian rhythm in humans: with sleep, posture and activity stripped away it still peaks in the evening (about 9 PM) with a peak-to-trough swing of 3–6 mm Hg systolic — and forcing behaviour out of phase with that rhythm raises 24-hour pressure

Shelf #10484 · Heart, vessels, blood pressure & clotting

PHYSIOLOGY — EMERGING

Stamped: 2026-11-28.

Evidence published: 2009–2017.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In healthy humans studied under constant-routine and forced-desynchrony conditions that remove the effects of sleep, posture, meals and activity, is there an endogenous circadian rhythm of arterial blood pressure — how large is it, when does it peak, and what happens to 24-hour blood pressure when behaviour is scheduled out of phase with the internal clock (circadian misalignment)?

Balance of the evidence

PHYSIOLOGY — EMERGING — Composition: three laboratory studies — a 28-person multi-protocol circadian study, a 10-person forced-desynchrony misalignment study, and a randomised crossover misalignment study in chronic shift workers whose record does not state its N (stated here on the face); total documented N = 38 plus the unstated shift-worker cohort, a small evidence base, which is why the stamp is EMERGING rather than ESTABLISHED. Diagnosis of the question first: the familiar day–night blood-pressure pattern is mostly behaviour (sleep lowers pressure, activity raises it), so the physiological question is what the internal clock itself contributes. Under constant routine and forced desynchrony the clock's own rhythm persists in every protocol: systolic pressure swings 3–6 mm Hg and diastolic 2–3 mm Hg peak-to-trough, peaking at the circadian time corresponding to about 9 PM — the evening, not the morning — and unrelated to the rhythms of cortisol, catecholamines, heart rate or urine flow. When behaviour is deliberately misaligned with the clock, 24-hour pressure rises: mean arterial pressure rose 3% in the 10-person study, and in shift workers misalignment raised 24-hour systolic pressure by 1.4 mm Hg and diastolic by 0.8 mm Hg, alongside an 11% rise in high-sensitivity C-reactive protein (a laboratory marker of inflammation; the change is stated neutrally here and its clinical direction is judged separately). PHYSIOLOGY — EMERGING: an endogenous circadian blood-pressure rhythm of a few mm Hg peaking in the evening is demonstrated under laboratory control, and circadian misalignment raises 24-hour pressure modestly — on a small, laboratory-bound evidence base.

MeSH: Adult · Blood Pressure · Blood Pressure Monitoring, Ambulatory · Cardiovascular Diseases · Circadian Rhythm · Female · Humans · Male · Time Factors · Young Adult · Chronobiology Disorders · Eating · Fasting · Metabolic Diseases · Postprandial Period · Prediabetic State · Sleep · Wakefulness · Biomarkers · C-Reactive Protein · Hypertension · Inflammation · Middle Aged · Risk Factors · Shift Work Schedule · Work Schedule Tolerance

Cards (3)

Card 1 — In 28 normotensive adults across constant-routine and forced-desynchrony protocols, blood pressure kept an endogenous circadian rhythm: peak-to-trough 3–6 mm Hg systolic and 2–3 mm Hg diastolic, peaking at the circadian time of about 9 PM (Shea 2011)

Study: Primary physiology study (constant routine / forced desynchrony), N = 28

Population: Twenty-eight normotensive adults (16 men) studied in three complementary multi-day laboratory protocols in dim light: a 38-hour constant routine, a 196-hour forced desynchrony of seven 28-hour days, and a 240-hour forced desynchrony of twelve 20-hour days, with circadian phase derived from core body temperature.

Summary: In 28 normotensive adults across constant-routine and forced-desynchrony protocols, blood pressure kept an endogenous circadian rhythm: peak-to-trough 3–6 mm Hg systolic and 2–3 mm Hg diastolic, peaking at the circadian time of about 9 PM (Shea 2011)

Result: Each protocol revealed a significant circadian rhythm in systolic and diastolic blood pressure with almost identical profiles. Peak-to-trough amplitudes were 3 to 6 mm Hg for systolic and 2 to 3 mm Hg for diastolic pressure. The highest pressure occurred at the circadian time corresponding to about 9:00 PM, so the endogenous rhythm is unlikely to underlie the morning peak in adverse cardiovascular events. The blood-pressure rhythm appeared unrelated to the circadian rhythms in cortisol, catecholamines, cardiac vagal modulation, heart rate or urine flow.

Watch out: Laboratory rhythms under enforced wakefulness and artificial day lengths show what the clock contributes; they do not reproduce the much larger day–night pressure differences of ordinary life, which are dominated by sleep and activity.

Source: Shea SA, Hilton MF, Hu K, Scheer FA. Existence of an endogenous circadian blood pressure rhythm in humans that peaks in the evening. Circulation research. 2011. PMID: 21474818. Registry ID: not stated in the record. MeSH: Adult · Blood Pressure · Blood Pressure Monitoring, Ambulatory · Cardiovascular Diseases · Circadian Rhythm · Female · Humans · Male · Time Factors · Young Adult

Card 2 — Ten adults lived on recurring 28-hour days for 10 days: circadian misalignment raised mean arterial pressure by 3% and left 3 of 8 evaluable subjects with postprandial glucose responses in the prediabetic range (Scheer 2009)

Study: Primary physiology study (forced desynchrony), N = 10

Population: Ten adults (5 female) in a 10-day laboratory protocol eating and sleeping at all circadian phases on a recurring 28-hour day, with four isocaloric meals per 28-hour day, hourly plasma sampling and daily blood pressure, heart rate and polysomnography; core temperature recorded continuously for circadian phase.

Summary: Ten adults lived on recurring 28-hour days for 10 days: circadian misalignment raised mean arterial pressure by 3% and left 3 of 8 evaluable subjects with postprandial glucose responses in the prediabetic range (Scheer 2009)

Result: When the behavioural cycle was misaligned with the endogenous circadian cycle, mean arterial pressure rose by 3% (P = 0.001) and sleep efficiency fell by 20%. Postprandial glucose responses reached the range typical of a prediabetic state in 3 of the 8 subjects with sufficient data. The authors present the findings as the acute laboratory counterpart of the misalignment experienced in jet lag and chronic shift work.

Watch out: Ten subjects in an extreme laboratory schedule: the study shows misalignment can raise pressure and worsen postprandial glucose handling over days; it does not measure what years of shift work do, and glucose values are reported as a range classification, not as individual mmol/L values.

Source: Scheer FA, Hilton MF, Mantzoros CS, Shea SA. Adverse metabolic and cardiovascular consequences of circadian misalignment. Proceedings of the National Academy of Sciences of the United States of America. 2009. PMID: 19255424. Registry ID: not stated in the record. MeSH: Adult · Cardiovascular Diseases · Chronobiology Disorders · Circadian Rhythm · Eating · Fasting · Female · Humans · Male · Metabolic Diseases · Postprandial Period · Prediabetic State · Sleep · Wakefulness

Card 3 — In chronic shift workers randomised to simulated night versus day work, misalignment raised 24-hour systolic pressure by 1.4 mm Hg and diastolic by 0.8 mm Hg, and high-sensitivity C-reactive protein by 11% (Morris 2017)

Study: Primary physiology study (randomised crossover laboratory simulation), N not documented in the record

Population: Chronic shift workers in two 3-day laboratory protocols — simulated night work with 12-hour inverted behavioural and environmental cycles (misalignment) versus simulated day work (alignment) — in a randomised crossover design. The record does not state the number of participants.

Summary: In chronic shift workers randomised to simulated night versus day work, misalignment raised 24-hour systolic pressure by 1.4 mm Hg and diastolic by 0.8 mm Hg, and high-sensitivity C-reactive protein by 11% (Morris 2017)

Result: Circadian misalignment increased 24-hour high-sensitivity C-reactive protein by 11% (p < 0.0001) and increased 24-hour systolic blood pressure by 1.4 mmHg and diastolic by 0.8 mmHg. The systolic rise was explained mainly by higher pressure during the wake period (+1.7 mmHg) and the diastolic rise mainly by higher pressure during the sleep opportunity (+1.8 mmHg).

Watch out: Participant number is not documented in the fetched record and is not estimated here; 3-day simulations in established shift workers may not generalise to people new to night work.

Source: Morris CJ, Purvis TE, Mistretta J, Hu K, Scheer FAJL. Circadian Misalignment Increases C-Reactive Protein and Blood Pressure in Chronic Shift Workers. Journal of biological rhythms. 2017. PMID: 28347188. Registry ID: not stated in the record. MeSH: Adult · Biomarkers · Blood Pressure · C-Reactive Protein · Cardiovascular Diseases · Chronobiology Disorders · Circadian Rhythm · Female · Humans · Hypertension · Inflammation · Male · Middle Aged · Risk Factors · Shift Work Schedule · Sleep · Work Schedule Tolerance · Young Adult