Fetal scalp blood pH predicts neonatal acidaemia poorly in the largest series: sensitivity (in words: the share of acidaemic babies it flagged) was 22% with an area under the curve of 0.59 across 1,422 UK samples, scalp and cord pH did not correlate even within 30 minutes of birth (r = −0.003), and a single-centre series found higher discrimination (0.77) but still low sensitivity (28.6%)
Shelf #10542 · Women’s health
PREDICTIVE PERFORMANCE — POOR
Stamped: 2026-11-28.
Evidence published: 2011–2025.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
How accurately does intrapartum fetal scalp blood sampling (pH, and scalp lactate) predict neonatal acidaemia, low Apgar scores and neonatal unit admission — what are its sensitivity, specificity and predictive values (each labelled in words) against umbilical cord blood at birth?
Balance of the evidence
PREDICTIVE PERFORMANCE — POOR — Composition: three accuracy studies (1,422 samples in 44 UK units + 407 births in one UK centre + 486 pregnancies in one Dutch centre). Diagnosis of the prediction problem first: scalp sampling is used as the tie-breaker when the fetal heart trace is pathological, so it must predict the baby's state at birth — but labour evolves between sampling and birth, and the test's numbers show it. In the 44-unit series, scalp pH values showed no correlation with umbilical cord pH in samples taken within an hour of birth (r = 0.001) or within half an hour (r = −0.003); a suboptimal scalp pH below 7.25 had a sensitivity (in words: the share of truly acidaemic babies it flagged) of 22% and a positive predictive value (in words: the share of flagged babies who were truly acidaemic) of 4.9%, with specificity (in words: the share of non-acidaemic babies it correctly cleared) of 87.3%, a negative predictive value of 97.4%, and an area under the curve of 0.59 for neonatal acidaemia. The single-centre series was kinder — area under the curve 0.77 for acidaemia and 0.80 for low Apgar — but at a pH threshold of 7.20 sensitivity was still only 28.6% against specificity of 85.5%. Scalp lactate correlated only moderately with scalp pH (r = −0.50); a lactate below 5.4 mmol/L (49 mg/dL) was the study's reassurance cut-off. PREDICTIVE PERFORMANCE — POOR: a normal scalp result usefully reassures (high negative predictive value), but an abnormal one is usually wrong and a reassuring one misses most babies who are born acidaemic.
MeSH: Acidosis · Blood Gas Analysis · Female · Fetal Blood · Fetal Distress · Humans · Hydrogen-Ion Concentration · Infant, Newborn · Labor, Obstetric · Male · Pregnancy · Pregnancy Outcome · Retrospective Studies · Scalp · United Kingdom · Adult · Apgar Score · Sensitivity and Specificity · ROC Curve · Academic Medical Centers · Biomarkers · Carbon Dioxide · Cohort Studies · Delivery, Obstetric · Fetal Monitoring · Gestational Age · Heart Rate, Fetal · Lactates · Predictive Value of Tests · Prenatal Diagnosis
Cards (3)
Card 1 — Across 1,422 fetal scalp samples in 44 UK units, scalp pH did not correlate with cord pH (r = 0.001 within 1 hour) and a pH below 7.25 had sensitivity 22% and positive predictive value 4.9% for neonatal acidaemia (2019 AB-FAB study)
Study: Multicentre predictive-accuracy study, N = 1,422 samples
Population: Retrospective multicentre service evaluation in 44 UK maternity units of women with singleton pregnancies who had fetal scalp blood sampling in labour; outcomes were umbilical cord arterial pH below 7.05 (neonatal acidaemia), Apgar below 7 at 1 and 5 minutes, and neonatal unit admission.
Summary: Across 1,422 fetal scalp samples in 44 UK units, scalp pH did not correlate with cord pH (r = 0.001 within 1 hour) and a pH below 7.25 had sensitivity 22% and positive predictive value 4.9% for neonatal acidaemia (2019 AB-FAB study)
Result: In total 1,422 samples were analysed; 41 babies (2.8%) had acidaemia at birth. Scalp and cord pH showed no correlation within an hour of birth (n = 314; r = 0.001, p = 0.9) or within half an hour (n = 115; r = −0.003, p = 0.9). A suboptimal scalp pH (below 7.25) had sensitivity (in words: the share of acidaemic babies flagged) of 22%, specificity (in words: the share of non-acidaemic babies cleared) of 87.3%, positive predictive value of 4.9% and negative predictive value of 97.4% for acidaemia; the area under the curve was 0.59. Performance for low Apgar scores and unit admission was similar (areas under the curve 0.55–0.58).
Watch out: Retrospective service-evaluation data with variable sampling-to-delivery intervals; the null correlation is the headline and is not explained away by timing in the study's own subgroup analyses.
Source: Al Wattar BH, Lakhiani A, Sacco A, Siddharth A, Bain A, Calvia A et al.. Evaluating the value of intrapartum fetal scalp blood sampling to predict adverse neonatal outcomes: A UK multicentre observational study. European journal of obstetrics, gynecology, and reproductive biology. 2019. PMID: 31229725. Registry ID: not stated in the record. MeSH: Acidosis · Blood Gas Analysis · Female · Fetal Blood · Fetal Distress · Humans · Hydrogen-Ion Concentration · Infant, Newborn · Labor, Obstetric · Male · Pregnancy · Pregnancy Outcome · Retrospective Studies · Scalp · United Kingdom
Card 2 — In 407 births sampled within an hour of delivery, scalp pH below 7.20 had sensitivity 28.6% and specificity 85.5% for neonatal acidaemia, with area under the curve 0.77 (2025 single-centre cohort)
Study: Single-centre predictive-accuracy cohort, N = 407
Population: Retrospective cohort of fetal scalp blood sampling performed less than 1 hour before birth at a single UK centre in 2016–2017; abnormal scalp pH defined as below 7.20; outcomes were low cord artery pH (below 7.20), neonatal acidaemia (cord pH below 7.05) and 5-minute Apgar below 7.
Summary: In 407 births sampled within an hour of delivery, scalp pH below 7.20 had sensitivity 28.6% and specificity 85.5% for neonatal acidaemia, with area under the curve 0.77 (2025 single-centre cohort)
Result: Data from 407 births were analysed. For neonatal acidaemia the area under the ROC curve was 0.77 (95% CI 0.65–0.88); for low Apgar scores it was 0.80 (0.70–0.90). A scalp pH below 7.20 had low sensitivity (in words: the share of affected babies flagged) and high specificity for neonatal acidaemia (28.6% and 85.5% respectively) and for low Apgar scores (38.1% and 90.82%). The authors suggest the test's high specificity and negative predictive value suit it to excluding asphyxia rather than confirming it.
Watch out: Single centre, retrospective, and restricted to samples within an hour of birth — the most favourable conditions for the test; its sensitivity is still under 30%, which is why the pack's grade follows the larger multicentre result.
Source: Godhard E, Michelotti F, Hayes DJL, Heazell AEP. Evaluating the diagnostic accuracy of fetal scalp blood sampling: A retrospective cohort study. European journal of obstetrics, gynecology, and reproductive biology. 2025. PMID: 39787963. Registry ID: not stated in the record. MeSH: Humans · Retrospective Studies · Female · Scalp · Pregnancy · Fetal Blood · Acidosis · Infant, Newborn · Adult · Hydrogen-Ion Concentration · Apgar Score · Sensitivity and Specificity · ROC Curve
Card 3 — In 486 pregnancies, scalp lactate correlated with scalp pH at r = −0.50 and with base deficit at r = 0.48; a lactate below 5.4 mmol/L (49 mg/dL) marked the study's reassurance zone (2011 scalp lactate study)
Study: Predictive-accuracy cohort (scalp lactate), N = 486
Population: Retrospective observational study at a Dutch university labour ward of 486 singleton pregnancies beyond 34 weeks with paired fetal scalp and cord blood acid-base and lactate values; metabolic acidosis at birth was defined as umbilical cord artery pH below 7.05 with raised base deficit.
Summary: In 486 pregnancies, scalp lactate correlated with scalp pH at r = −0.50 and with base deficit at r = 0.48; a lactate below 5.4 mmol/L (49 mg/dL) marked the study's reassurance zone (2011 scalp lactate study)
Result: Fetal scalp lactate increased with evolving metabolic acidosis and correlated with scalp pH (r = −0.50, p < 0.01) and base deficit (r = 0.48, p < 0.01). A lactate concentration below 5.4 mmol/L (49 mg/dL) indicated the reassuring range in the authors' percentile-based cut-off analysis, with a higher cut-off marking the zone for immediate intervention.
Watch out: Correlation with scalp pH is not accuracy against the baby's outcome — the outcome-anchored figures come from the pH studies; this card is carded for the lactate cut-off the record actually derives, and only the reassurance cut-off verified from the record is printed on this card.
Source: Heinis AM, Spaanderman ME, Gunnewiek JM, Lotgering FK. Scalp blood lactate for intra-partum assessment of fetal metabolic acidosis. Acta obstetricia et gynecologica Scandinavica. 2011. PMID: 21751970. Registry ID: not stated in the record. MeSH: Academic Medical Centers · Acidosis · Adult · Biomarkers · Carbon Dioxide · Cohort Studies · Delivery, Obstetric · Female · Fetal Blood · Fetal Monitoring · Gestational Age · Heart Rate, Fetal · Humans · Hydrogen-Ion Concentration · Infant, Newborn · Lactates · Predictive Value of Tests · Pregnancy · Pregnancy Outcome · Prenatal Diagnosis · Retrospective Studies · Scalp · Sensitivity and Specificity