SourceMed · Shelf #1055 in the ask interface

Regional citrate versus systemic heparin anticoagulation for continuous kidney replacement (RICH)

Shelf #1055 · Kidney, fluids & electrolytes

Stamped: development phase, October–November 2026 — exact date not recorded.

Evidence published: 2020.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In critically ill patients with acute kidney injury on continuous kidney replacement therapy, does regional citrate anticoagulation prolong filter life and change mortality versus systemic heparin anticoagulation?

Balance of the evidence

POSSIBLE (Tier C at build: 90-day mortality was a coprimary outcome of RICH, so the shelf carries a mortality outcome on its face even though no mortality benefit is claimed). In RICH (596 patients, terminated early), regional citrate prolonged median filter life (47 versus 26 hours; P<0.001) and halved-plus bleeding complications (5.1% versus 16.9%), but 90-day mortality did not differ significantly (51.2% versus 53.6% Kaplan–Meier; adjusted hazard ratio 0.79, 95% CI 0.63 to 1.004; P=0.054) in a trial the authors state was underpowered for mortality after early termination, and new infections were more frequent with citrate (68.0% versus 55.4%). Single trial, early stop: POSSIBLE.

MeSH: Acute Kidney Injury/blood,mortality,therapy · Anticoagulants/administration & dosage,adverse effects · Calcium/blood · Citric Acid/administration & dosage,adverse effects · Continuous Renal Replacement Therapy/instrumentation,mortality · Critical Illness · Early Termination of Clinical Trials

Cards (2)

Card 1 — RICH (Zarbock 2020): citrate prolonged filter life (47 vs 26 hours) and cut bleeding, but 90-day mortality was not significantly different and infections rose

Study: Parallel-group, randomised multicentre trial (26 centres, Germany), terminated early

Population: 596 critically ill patients with severe acute kidney injury or indications for kidney replacement therapy completed the trial (638 randomised), assigned to regional citrate anticoagulation (300) or systemic heparin anticoagulation (296) during continuous kidney replacement therapy; mean age 67.5 years, 30.7% women (183 of 596).

Summary: RICH 2020: citrate prolonged filter life (47 vs 26 hours) and cut bleeding (5.1% vs 16.9%); 90-day mortality — a coprimary outcome — was 51.2% vs 53.6%, not significant in an early-terminated trial.

Result: Median filter life span was 47 hours (IQR 19–70) with citrate versus 26 hours (IQR 12–51) with heparin (difference 15 hours, 95% CI 11 to 20; P<0.001). Ninety-day all-cause mortality — the coprimary outcome — occurred in 150 of 300 versus 156 of 296 patients (Kaplan–Meier 51.2% versus 53.6%; unadjusted hazard ratio 0.91, 95% CI 0.72 to 1.13; adjusted hazard ratio 0.79, 95% CI 0.63 to 1.004; adjusted P=0.054). Bleeding complications were fewer with citrate (15/300 [5.1%] versus 49/296 [16.9%]; difference −11.8%, 95% CI −16.8% to −6.8%; P<0.001); new infections were more frequent (204/300 [68.0%] versus 164/296 [55.4%]; difference 12.6%, 95% CI 4.9% to 20.3%; P=0.002). Of 38 prespecified secondary end points, 34 showed no significant difference.

Watch out: The trial was terminated early and was therefore underpowered for mortality, as the authors state — the adjusted mortality P of 0.054 is not a near-miss benefit claim. The infection excess with citrate is part of the balance, not a footnote.

Source: Zarbock A et al. Effect of Regional Citrate Anticoagulation vs Systemic Heparin Anticoagulation During Continuous Kidney Replacement Therapy on Dialysis Filter Life Span and Mortality Among Critically Ill Patients With Acute Kidney Injury: The RICH Randomized Clinical Trial. JAMA. 2020;324(16):1629-1639. PMID: 33095849. Registry ID: ClinicalTrials.gov NCT02669589, from the record's databank fields.

Estimate type: unadjusted estimate, as stated in the card.

Card 2 — Synthesis: citrate is the better circuit anticoagulant for filter life and bleeding; a mortality effect is unproven — POSSIBLE, Tier C

Study: Synthesis

Population: Synthesis of the card above: RICH (596 critically ill patients on continuous kidney replacement therapy).

Summary: Citrate is the better circuit anticoagulant for filter life and bleeding; a mortality effect is unproven — POSSIBLE, Tier C (coprimary mortality),.

Result: RICH separates a circuit outcome from a patient outcome: filter life up by a median 21 hours and bleeding down from 16.9% to 5.1%, against a null-on-significance mortality coprimary (51.2% versus 53.6%) in an early-terminated trial, plus more new infections with citrate (68.0% versus 55.4%). Tier C ruling at build: mortality was a coprimary outcome, so. Dialysis dose/intensity is home on Shelf #754 and dialysis timing on Shelves #195/#292 — none is re-carded here.

Watch out: Guideline first-line status for citrate rests heavily on this one early-stopped trial plus older small trials and meta-analyses; the shelf stamp reflects the randomised record carded here, not the guideline consensus.

Source: Synthesis of Zarbock A et al. JAMA. 2020;324(16):1629-1639. PMID: 33095849. Registry ID as on the individual card.