SourceMed · Shelf #10589 in the ask interface
Early caries detection is a trade-off no single method wins: pooled visual examination had sensitivity (in words: the share of truly carious surfaces it flagged) of 0.86 and specificity (in words: the share of sound surfaces it correctly cleared) of 0.77 across 19,590 tooth surfaces, bitewing radiography missed most early occlusal lesions (sensitivity 0–0.29 in permanent teeth), and secondary-caries methods all sat near sensitivity 0.50–0.59
Shelf #10589 · Eyes, skin, nose & allergy
MEASUREMENT ACCURACY — PARTIAL
Stamped: 2026-11-28.
Evidence published: 2016–2021.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
How accurately do visual/visual-tactile examination (ICDAS and related systems), bitewing radiography and laser-fluorescence devices detect early (enamel) and secondary dental caries against histology, excavation or operative reference standards — what are their sensitivity and specificity (each labelled in words)?
Balance of the evidence
MEASUREMENT ACCURACY — PARTIAL — Composition: one Cochrane diagnostic-accuracy review (71 datasets, 19,590 tooth sites/surfaces), one systematic review and meta-analysis of early-caries methods (51 articles) and one of secondary caries (23 studies). Diagnosis of the measurement problem first: a detection method must flag early lesions while they are still reversible without also condemning sound surfaces to drilling, so sensitivity (in words: the share of truly carious surfaces it flagged) and specificity (in words: the share of sound surfaces it correctly cleared) pull against each other and no method maximises both. Pooled across visual classification systems, sensitivity was 0.86 (95% CI 0.80 to 0.90) and specificity 0.77 (95% CI 0.72 to 0.82), but individual-study values ranged from 0.16 to 1.00 and 0 to 1.00 — the pooled point hides wide dispersion, and 48 of the datasets were in vitro. By method and surface: bitewing radiography had the lowest sensitivity for early occlusal lesions in permanent teeth (0–0.29) with high specificity (0.96–1), laser-fluorescence pens the highest sensitivity (0.81–0.89) at lower specificity (0.71–0.8), and approximal surfaces reversed the ranking. For secondary caries beside existing restorations, visual, radiographic and laser-fluorescence methods were all similar — sensitivities 0.50 to 0.59, specificities 0.78 to 0.83 — and tactile probing performed worst. MEASUREMENT ACCURACY — PARTIAL: visual examination is a reasonable first test and adjuncts shift the sensitivity–specificity balance by surface, but every method misses a substantial share of early or secondary lesions.
MeSH: Adult · Bias · Child · Confidence Intervals · Dental Caries · Dental Enamel · Early Diagnosis · Humans · Palpation · Physical Examination · Sensitivity and Specificity · Dental Caries Susceptibility · Dentition, Permanent · Radiography, Bitewing · Reproducibility of Results · Tooth, Deciduous · Dental Restoration, Permanent · Fluorescence · Lasers · Recurrence · Touch · Transillumination · Visual Perception
Cards (3)
Card 1 — Across 71 datasets and 19,590 tooth surfaces, visual classification systems for enamel caries pooled at sensitivity 0.86 (95% CI 0.80–0.90) and specificity 0.77 (0.72–0.82), with individual-study sensitivities ranging from 0.16 to 1.00 (2021 Cochrane review)
Study: Cochrane diagnostic test accuracy review, 67 studies / 19,590 tooth surfaces
Population: Sixty-seven studies (71 datasets; 48 completed in vitro) of visual or visual-tactile classification systems — most often ICDAS (36 studies) and the Ekstrand-Ricketts-Kidd system (15) — against histology, excavation or radiographic reference standards, at tooth-surface level. Sensitivity and specificity are labelled in words in this pack's balance at first occurrence.
Summary: Across 71 datasets and 19,590 tooth surfaces, visual classification systems for enamel caries pooled at sensitivity 0.86 (95% CI 0.80–0.90) and specificity 0.77 (0.72–0.82), with individual-study sensitivities ranging from 0.16 to 1.00 (2021 Cochrane review)
Result: Summary sensitivity was 0.86 (95% CI 0.80 to 0.90) and summary specificity 0.77 (95% CI 0.72 to 0.82), diagnostic odds ratio 20.38 (95% CI 14.33 to 28.98), estimated by hierarchical bivariate meta-analysis. There was substantial variability: individual sensitivities ranged from 0.16 to 1.00 and specificities from 0 to 1.00. Only two studies were at low risk of bias across all four QUADAS-2 domains, and applicability concerns were high for patient selection and index test because so many studies used extracted teeth.
Watch out: Nearly three-quarters of the evidence is in vitro on extracted teeth; in-mouth performance with saliva, plaque and limited access is likely worse, and the pooled point should not be quoted without the ranges.
Source: Macey R, Walsh T et al.. Visual or visual-tactile examination to detect and inform the diagnosis of enamel caries. The Cochrane database of systematic reviews. 2021. PMID: 34124773. Registry ID: not stated in the record. MeSH: Adult · Bias · Child · Confidence Intervals · Dental Caries · Dental Enamel · Early Diagnosis · Humans · Palpation · Physical Examination · Sensitivity and Specificity
Card 2 — For early occlusal caries in permanent teeth, bitewing radiography sensitivity was 0–0.29 against histology while laser-fluorescence pen sensitivity was 0.81–0.89; on approximal surfaces bitewing sensitivity rose to 0.75–0.83 (2021 meta-analysis of 51 articles)
Study: Systematic review and meta-analysis (early caries detection methods), 51 articles
Population: Fifty-one diagnostic-accuracy articles (2000–2019) on incipient caries in permanent and primary teeth, comparing ICDAS-II visual scoring, bitewing radiography and DIAGNOdent laser-fluorescence devices against histological or operative reference standards, by surface.
Summary: For early occlusal caries in permanent teeth, bitewing radiography sensitivity was 0–0.29 against histology while laser-fluorescence pen sensitivity was 0.81–0.89; on approximal surfaces bitewing sensitivity rose to 0.75–0.83 (2021 meta-analysis of 51 articles)
Result: For permanent teeth on occlusal surfaces against histology, sensitivity ranges were: DIAGNOdent Pen 0.81–0.89, ICDAS-II 0.62–1, DIAGNOdent 0.48–1, bitewing radiography 0–0.29; corresponding specificity ranges were 0.71–0.8, 0.5–0.84, 0.54–1 and 0.96–1. Against operative reference the ordering was similar. For approximal surfaces, sensitivity was bitewing 0.75–0.83, DIAGNOdent Pen 0.6 and ICDAS-II 0.54, with specificities 0.6–0.9, 0.2 and 1 respectively. The authors conclude robust conclusions cannot be drawn and methods should be used as adjuncts to clinical examination.
Watch out: Ranges span heterogeneous thresholds and settings rather than pooled points; a sensitivity range that includes 0 and 1 for the same device class signals threshold and spectrum differences between studies, not device randomness alone.
Source: Foros P, Oikonomou E et al.. Detection Methods for Early Caries Diagnosis: A Systematic Review and Meta-Analysis. Caries research. 2021. PMID: 34130279. Registry ID: not stated in the record. MeSH: Dental Caries · Dental Caries Susceptibility · Dentition, Permanent · Humans · Radiography, Bitewing · Reproducibility of Results · Sensitivity and Specificity · Tooth, Deciduous
Card 3 — For secondary caries beside existing restorations, visual, radiographic and laser-fluorescence detection had similar sensitivities (0.50–0.59) and specificities (0.78–0.83) across 23 studies, and tactile assessment was least accurate (2016 meta-analysis)
Study: Systematic review and meta-analysis (secondary caries detection), 23 studies
Population: Twenty-three clinical or in-vitro studies of five detection methods — visual, tactile, radiography, laser fluorescence and quantitative light-induced fluorescence — for natural or artificially induced secondary lesions on proximal (14 studies) or other surfaces, adjacent to amalgam (16 studies) or tooth-coloured materials, verified against an established reference test.
Summary: For secondary caries beside existing restorations, visual, radiographic and laser-fluorescence detection had similar sensitivities (0.50–0.59) and specificities (0.78–0.83) across 23 studies, and tactile assessment was least accurate (2016 meta-analysis)
Result: Visual (11 studies), radiographic (13) and laser-fluorescence (8) detection had similar sensitivities (0.50 to 0.59) and specificities (0.78 to 0.83); visual assessment was more accurate on nonproximal surfaces and laser fluorescence adjacent to composites. Tactile assessment (7 studies) had low accuracy. Quantitative light-induced fluorescence (3 studies) was sensitive on nonproximal surfaces but had low specificities. Most analyses appeared to suffer from publication bias, and most studies had high risk of bias or applicability concerns.
Watch out: Mostly in-vitro work on posterior permanent teeth; sensitivity near 0.5 means about half of recurrent lesions beside restorations are missed by any single method in these studies.
Source: Brouwer F, Askar H et al.. Detecting Secondary Caries Lesions: A Systematic Review and Meta-analysis. Journal of dental research. 2016. PMID: 26464398. Registry ID: not stated in the record. MeSH: Dental Caries · Dental Restoration, Permanent · Fluorescence · Humans · Lasers · Physical Examination · Radiography, Bitewing · Recurrence · Reproducibility of Results · Sensitivity and Specificity · Touch · Transillumination · Visual Perception