Anti-Müllerian hormone for diagnosing polycystic ovary syndrome: four meta-analyses pool sensitivity (in words: the share of women with PCOS the test identifies) at 0.76–0.79 and specificity (in words: the share of women without PCOS it correctly clears) at 0.86–0.87 in adults — useful, but no agreed cut-off, and weaker in adolescents

Shelf #10614 · Women’s health

MEASUREMENT ACCURACY — PARTIAL

Stamped: 2026-11-28.

Evidence published: 2013–2024.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In women being evaluated for polycystic ovary syndrome, how accurately does a serum anti-Müllerian hormone (AMH) measurement diagnose PCOS against the Rotterdam criteria — what are its pooled sensitivity and specificity (each labelled in words), does it perform better when it replaces ultrasound polycystic-ovary morphology inside the criteria, and how does it perform in adolescents?

Balance of the evidence

MEASUREMENT ACCURACY — PARTIAL — Composition: four overlapping systematic reviews and meta-analyses of diagnostic accuracy studies (10, 29, 41 and 82 included studies; the largest documented subject count is 13,509 women in the 41-study pool, and the pools overlap, so the totals must not be added). Diagnosis of the measurement problem first: PCOS diagnosis rests on the Rotterdam criteria, whose ultrasound limb (polycystic ovarian morphology) is operator- and equipment-dependent; AMH is proposed as a blood-test substitute, and it must be judged on sensitivity (in words: the share of women with PCOS the test identifies) and specificity (in words: the share of women without PCOS the test correctly clears). The four syntheses agree closely for AMH alone in adults: pooled sensitivity 0.76–0.79 and specificity 0.86–0.87, with summary areas under the curve of 0.87–0.89. Substituting AMH for the ultrasound morphology limb inside the criteria performed better on paper (sensitivity 0.93, specificity 0.99 in one pool) — but that comparison is partly circular, since AMH and follicle count measure the same ovarian biology. In adolescents the test is materially weaker (sensitivity 0.66, specificity 0.78). No synthesis could recommend an international cut-off: assays and thresholds differ across studies, and heterogeneity is high (I² up to 94%). MEASUREMENT ACCURACY — PARTIAL: a useful adjunct and, in adults, a defensible stand-in for the morphology criterion — not a stand-alone diagnostic test with a universal threshold.

MeSH: Anti-Mullerian Hormone · Female · Humans · Polycystic Ovary Syndrome · ROC Curve

Cards (5)

Card 1 — First meta-analysis (10 studies; individual data extracted from 4): at a cut-off of 4.7 ng/mL, AMH had sensitivity 82.8% and specificity 79.4% for PCOS in symptomatic women, area under the curve 0.87 (2013)

Study: Systematic review and meta-analysis of diagnostic accuracy

Population: Women evaluated for PCOS against the Rotterdam criteria, in 10 observational accuracy studies; individual-level data were extracted from published plots in 4 of them. Sensitivity and specificity are labelled in words in this pack's balance at first occurrence.

Summary: First meta-analysis (10 studies; individual data extracted from 4): at a cut-off of 4.7 ng/mL, AMH had sensitivity 82.8% and specificity 79.4% for PCOS in symptomatic women, area under the curve 0.87 (2013)

Result: For a cut-off of 4.7 ng/mL, the extracted-data meta-analysis gave sensitivity 82.8% and specificity 79.4%, with an area under the curve of 0.87 (95% CI 0.83–0.92) — identical to the summary ROC area (0.87) across all 10 studies. The authors concluded AMH may be a useful initial diagnostic test, subject to prospective validation.

Watch out: Part of the pool rests on data digitised from published graphs, and the population is symptomatic referred women — accuracy will be lower in unselected populations.

Source: Iliodromiti S et al. J Clin Endocrinol Metab. 2013 (PMID: 23775353). No registry ID stated in the record.

Card 2 — Updated meta-analysis (29 studies): AMH alone pooled at sensitivity 0.76 and specificity 0.86; AMH substituted for ultrasound morphology inside the Rotterdam criteria pooled at sensitivity 0.93 and specificity 0.99 (2019)

Study: Systematic review and meta-analysis of diagnostic accuracy

Population: 29 diagnostic accuracy studies of AMH for PCOS (Rotterdam-defined), including analyses where AMH replaced polycystic ovarian morphology (PCOM) as one of the Rotterdam criteria.

Summary: Updated meta-analysis (29 studies): AMH alone pooled at sensitivity 0.76 and specificity 0.86; AMH substituted for ultrasound morphology inside the Rotterdam criteria pooled at sensitivity 0.93 and specificity 0.99 (2019)

Result: AMH alone: pooled sensitivity 0.76 (95% CI 0.71–0.81), specificity 0.86 (95% CI 0.82–0.90), diagnostic odds ratio 20 (95% CI 12–33), summary ROC area 0.88. With AMH replacing PCOM: sensitivity 0.93 (95% CI 0.89–0.96), specificity 0.99 (95% CI 0.95–1.00), diagnostic odds ratio 1,634, summary ROC area 0.97 — significantly higher (Z = 4.89, P < .01).

Watch out: The substitution analysis is vulnerable to incorporation bias: AMH correlates strongly with the follicle count it replaces, so agreement with a criteria set containing its biological twin overstates independent diagnostic value.

Source: Zhao Y et al. Endocr Pract. 2019 (PMID: 31414908). No registry ID stated in the record.

Card 3 — Largest subject pool (41 studies, 13,509 women): pooled sensitivity 0.78, specificity 0.87, diagnostic odds ratio 24 — with substantial heterogeneity and no settled cut-off (2022)

Study: Systematic review and meta-analysis of diagnostic accuracy

Population: 41 diagnostic accuracy studies involving 13,509 subjects, pooled with random-effects models; risk of bias assessed with QUADAS-2 (protocol registered in PROSPERO as CRD42021246910, as stated in the record).

Summary: Largest subject pool (41 studies, 13,509 women): pooled sensitivity 0.78, specificity 0.87, diagnostic odds ratio 24 — with substantial heterogeneity and no settled cut-off (2022)

Result: Pooled sensitivity 0.78 (95% CI 0.74–0.81), specificity 0.87 (95% CI 0.84–0.90), diagnostic odds ratio 24 (95% CI 15–37), summary ROC area 0.89 (95% CI 0.86–0.92). The most prominent biases were in patient selection and index-test assessment, and the authors called for individual-patient-data analysis to identify an optimal cut-off.

Watch out: Overlaps heavily with the 2013 and 2019 pools carded here; it is a re-pooling of substantially the same primary literature, not independent confirmation.

Source: Anand S et al. J Obstet Gynaecol Res. 2022 (PMID: 35394100). PROSPERO registration CRD42021246910 as stated in the record.

Card 4 — Guideline meta-analysis for the 2023 international PCOS guideline (82 studies): adults — sensitivity 0.79, specificity 0.87; adolescents — sensitivity 0.66, specificity 0.78; no international cut-off could be recommended (2024)

Study: Systematic review and meta-analysis of diagnostic accuracy (guideline evidence synthesis)

Population: 82 studies: 68 in the adult AMH-for-PCOS-diagnosis pool, 11 in the adolescent pool, and 7 in the adult AMH-for-polycystic-ovarian-morphology pool, assembled for the 2023 international evidence-based PCOS guideline.

Summary: Guideline meta-analysis for the 2023 international PCOS guideline (82 studies): adults — sensitivity 0.79, specificity 0.87; adolescents — sensitivity 0.66, specificity 0.78; no international cut-off could be recommended (2024)

Result: Adults, AMH for PCOS diagnosis: pooled sensitivity 0.79 (95% CI 0.76–0.82; I² = 86%) and specificity 0.87 (95% CI 0.84–0.89; I² = 91%). Adolescents: sensitivity 0.66 (95% CI 0.58–0.73) and specificity 0.78 (95% CI 0.71–0.83). Adults, AMH for detecting polycystic ovarian morphology: sensitivity 0.79 and specificity 0.87. The authors concluded AMH alone is insufficient for PCOS diagnosis, is non-specific for morphology in adolescents, and that assay and population differences prevented recommending any international cut-off.

Watch out: Heterogeneity is very high in every pool (I² 74–94%); pooled points summarise a wide spread of study-level accuracies driven by assay, cut-off and case mix.

Source: van der Ham K et al. Fertil Steril. 2024 (PMID: 38944177). No registry ID stated in the record.

Card 5 — Synthesis: AMH performs consistently moderately in adults and poorly in adolescents, with no transferable threshold — MEASUREMENT ACCURACY — PARTIAL

Study: Synthesis

Population: Four overlapping meta-analyses (10–82 studies; largest documented pool 13,509 women).

Summary: Synthesis: AMH performs consistently moderately in adults and poorly in adolescents, with no transferable threshold — MEASUREMENT ACCURACY — PARTIAL

Result: Adult sensitivity clusters at 0.76–0.79 and specificity at 0.86–0.87 across all four syntheses; adolescent accuracy is clearly lower (0.66 / 0.78), and the apparently superior performance when AMH replaces ultrasound morphology is partly circular. MEASUREMENT ACCURACY — PARTIAL stamp as in the balance.

Watch out: Every card is a synthesis of substantially the same primary studies; the shelf documents consistency of the pooled estimate, not four independent bodies of evidence.

Source: Synthesis of Iliodromiti 2013 (PMID: 23775353), Zhao 2019 (PMID: 31414908), Anand 2022 (PMID: 35394100) and van der Ham 2024 (PMID: 38944177).