Thyroglobulin in lymph-node fine-needle aspiration washout (FNA-Tg) for metastatic differentiated thyroid cancer: four meta-analyses pool sensitivity (in words: the share of metastatic nodes the test identifies) at 0.89–0.95 and specificity (in words: the share of benign nodes it correctly clears) at 0.94–0.95 overall — but preoperative specificity fell to 0.60 in one pool and no cut-off is standardised

Shelf #10615 · Thyroid & parathyroid

MEASUREMENT ACCURACY — PARTIAL

Stamped: 2026-11-28.

Evidence published: 2014–2020.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with suspicious neck lymph nodes during thyroid-nodule workup or differentiated thyroid cancer follow-up, how accurately does measuring thyroglobulin in the fine-needle aspiration washout (FNA-Tg) — alone and combined with cytology — detect lymph-node metastasis, what are its pooled sensitivity and specificity (each labelled in words), and how much does performance vary between the preoperative and post-thyroidectomy settings and by cut-off?

Balance of the evidence

MEASUREMENT ACCURACY — PARTIAL — Composition: four overlapping systematic reviews and meta-analyses of diagnostic accuracy (24 studies / 2,865 lymph nodes; 22 studies / 2,670 lymph nodes; 2,257 patients with 2,786 node samples; and 8 studies / 843 lymph nodes restricted to washouts rinsed with 1 mL of saline). The pools overlap, so node counts must not be added. Diagnosis of the measurement problem first: cytology of a suspicious neck node is often non-diagnostic or falsely reassuring, particularly in small or cystic nodes; FNA-Tg must be judged on sensitivity (in words: the share of metastatic nodes the test identifies) and specificity (in words: the share of benign nodes the test correctly clears) against histology or follow-up. The syntheses agree that overall accuracy is high — pooled sensitivity 0.91–0.95 and specificity 0.94–0.95, rising further when FNA-Tg is combined with cytology (sensitivity 0.968, specificity 0.932 in the network meta-analysis). But the performance is setting-dependent: after thyroidectomy, one pool found sensitivity and specificity both at 1.0, while before thyroidectomy — with the gland in place and thyroglobulin contamination possible — specificity fell to 0.60, and the recommended cut-offs diverged wildly between settings (32.04 ng/mL preoperative versus 0.9 ng/mL postoperative in that pool; 1 ng/mL maximised sensitivity and 40 ng/mL maximised specificity in another). Every synthesis ends on the same caveat: patient selection, assay method and cut-off are not standardised. MEASUREMENT ACCURACY — PARTIAL.

MeSH: Biopsy, Fine-Needle · Carcinoma, Papillary, Follicular · Cross-Sectional Studies · Humans · Longitudinal Studies · Lymph Nodes · Lymphatic Metastasis · Sensitivity and Specificity · Thyroglobulin · Thyroid Neoplasms

Cards (5)

Card 1 — Largest early pool (24 studies, 2,865 lymph nodes): overall sensitivity 95.0% and specificity 94.5% — but with the thyroid still in place, sensitivity fell to 86.2% and specificity to 90.2% (2014)

Study: Systematic review and meta-analysis of diagnostic accuracy

Population: Patients with suspicious neck lymph nodes during thyroid-nodule workup or thyroid cancer follow-up, in 24 accuracy studies (2,865 nodes), with pre-specified strata for patients with the thyroid gland in situ (410 nodes) and after thyroidectomy (1,007 nodes). Sensitivity and specificity are labelled in words in this pack's balance at first occurrence.

Summary: Largest early pool (24 studies, 2,865 lymph nodes): overall sensitivity 95.0% and specificity 94.5% — but with the thyroid still in place, sensitivity fell to 86.2% and specificity to 90.2% (2014)

Result: Overall pooled sensitivity was 95.0% (95% CI 93.7–96.0%), specificity 94.5% (95% CI 93.2–95.7%) and diagnostic odds ratio 338.91, with significant heterogeneity (I² = 65.7%). With the thyroid in place: sensitivity 86.2%, specificity 90.2%, diagnostic odds ratio 56.6. After thyroidectomy: sensitivity 96.9%, specificity 94.1%, diagnostic odds ratio 407.65, with no heterogeneity (I² = 0.0%).

Watch out: The headline pool mixes preoperative and postoperative nodes, two situations with different contamination risks and different achievable accuracy; the stratified figures are the clinically usable ones.

Source: Grani G et al. J Clin Endocrinol Metab. 2014 (PMID: 24617715). No registry ID stated in the record.

Card 2 — Second pool (22 studies, 2,670 lymph nodes): sensitivity 0.91, specificity 0.94 — and the cut-off was a source of heterogeneity for both, with 1 ng/mL maximising sensitivity and 40 ng/mL maximising specificity (2020)

Study: Systematic review and meta-analysis of diagnostic accuracy

Population: Participants with suspicious neck lymph nodes during thyroid-nodule workup or papillary thyroid cancer follow-up, in 22 accuracy studies (2,670 nodes).

Summary: Second pool (22 studies, 2,670 lymph nodes): sensitivity 0.91, specificity 0.94 — and the cut-off was a source of heterogeneity for both, with 1 ng/mL maximising sensitivity and 40 ng/mL maximising specificity (2020)

Result: Pooled sensitivity for FNA-Tg was 0.91 (95% CI 0.87–0.93) and specificity 0.94 (95% CI 0.91–0.96). Meta-regression identified the cut-off value and serum thyroglobulin status as sources of heterogeneity for sensitivity, and the cut-off as a source for specificity. In subgroup analysis, a 1 ng/mL cut-off had the highest sensitivity and a 40 ng/mL cut-off the highest specificity.

Watch out: A forty-fold range between the sensitivity-maximising and specificity-maximising cut-offs means a laboratory's chosen threshold, not the analyte, decides what kind of test this is.

Source: Zhu XH et al. Endocr J. 2020 (PMID: 31723088). No registry ID stated in the record.

Card 3 — Network meta-analysis (2,257 patients, 2,786 node samples): combining cytology with FNA-Tg beat either alone — combination sensitivity 0.968 and specificity 0.932, summary ROC score 0.99 (2019)

Study: Systematic review and network meta-analysis of diagnostic accuracy

Population: 2,257 patients contributing 2,786 samples of suspicious metastatic lymph nodes of differentiated thyroid cancer, across the studies pooled for cytology (FNAC), FNA-Tg and their combination.

Summary: Network meta-analysis (2,257 patients, 2,786 node samples): combining cytology with FNA-Tg beat either alone — combination sensitivity 0.968 and specificity 0.932, summary ROC score 0.99 (2019)

Result: The diagnostic ranking was combination of FNAC and FNA-Tg above FNA-Tg above FNAC, with all differences statistically significant. The combination's sensitivity was 0.968 (95% CI 0.942–0.983), specificity 0.932 (95% CI 0.856–0.969), diagnostic odds ratio 418.424 and summary receiver operating characteristic score 0.99 (95% CI 0.97–0.99). The authors recommended the combination for diagnosing nodal metastasis.

Watch out: The combination's specificity (0.932) is lower than FNA-Tg alone in the other pools carded here — combining tests trades a little specificity for sensitivity, and cross-pool comparisons are indirect.

Source: Xu Y et al. Medicine (Baltimore). 2019 (PMID: 31702649). No registry ID stated in the record.

Card 4 — Saline-standardised pool (8 studies, 843 lymph nodes): postoperative sensitivity and specificity both 1.0, but preoperative specificity was only 0.60 — with best cut-offs of 0.9 ng/mL after surgery versus 32.04 ng/mL before it (2015)

Study: Systematic review and meta-analysis of diagnostic accuracy

Population: Patients with thyroid cancer and lymph nodes assessed by FNA-Tg in washout fluid rinsed with 1 mL of normal saline, in 8 eligible studies (843 nodes), split into preoperative and postoperative studies.

Summary: Saline-standardised pool (8 studies, 843 lymph nodes): postoperative sensitivity and specificity both 1.0, but preoperative specificity was only 0.60 — with best cut-offs of 0.9 ng/mL after surgery versus 32.04 ng/mL before it (2015)

Result: Preoperative pooled sensitivity was 0.89 (95% CI 0.82–0.95) and specificity 0.60 (95% CI 0.49–0.70). Postoperative pooled sensitivity was 1.0 (95% CI 0.83–1.0) and specificity 1.0 (95% CI 0.92–1.0). The distance-based best cut-offs were 32.04 ng/mL preoperatively and 0.9 ng/mL postoperatively.

Watch out: The perfect postoperative figures rest on few studies with confidence intervals reaching down to 0.83–0.92, and the preoperative specificity of 0.60 is the weakest number on this shelf — the test's accuracy cannot be quoted without its setting.

Source: Pak K et al. Endocrine. 2015 (PMID: 25185721). No registry ID stated in the record.

Card 5 — Synthesis: FNA-Tg is highly accurate after thyroidectomy and materially weaker before it, with no standardised cut-off — MEASUREMENT ACCURACY — PARTIAL

Study: Synthesis

Population: Four overlapping meta-analyses (8–24 studies; 843–2,865 nodes each).

Summary: Synthesis: FNA-Tg is highly accurate after thyroidectomy and materially weaker before it, with no standardised cut-off — MEASUREMENT ACCURACY — PARTIAL

Result: Overall pooled sensitivity 0.91–0.95 and specificity 0.94–0.95 conceal a setting split: postoperative performance approaches perfection in small pools, preoperative specificity falls as low as 0.60, and proposed cut-offs span 0.9–40 ng/mL. MEASUREMENT ACCURACY — PARTIAL stamp as in the balance.

Watch out: All four cards are syntheses of substantially overlapping primary studies; consistency across them reflects the same underlying literature re-pooled, not independent replication.

Source: Synthesis of Grani 2014 (PMID: 24617715), Zhu 2020 (PMID: 31723088), Xu 2019 (PMID: 31702649) and Pak 2015 (PMID: 25185721).