Urine Histoplasma antigen is a rule-in test, not a rule-out test: sensitivity (in words: the share of proven cases detected) of 90–91% for the better assays in advanced HIV but only 19% in HIV-negative patients, while specificity (in words: the share of non-cases correctly cleared) stays at 91–100%

Shelf #10628 · Critical care & sepsis

MEASUREMENT ACCURACY — PARTIAL

Stamped: 2026-11-28.

Evidence published: 2021–2026.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

How accurately does Histoplasma antigen detection (in urine, by enzyme immunoassay, galactomannan assay or lateral-flow assay) diagnose disseminated histoplasmosis — what sensitivity and specificity (each labelled in words) does it achieve in people with and without HIV?

Balance of the evidence

MEASUREMENT ACCURACY — PARTIAL — Composition: one prospective multicentre accuracy study in HIV (415 enrolled, 108 proven cases), one retrospective cohort in HIV-negative patients (346) and one field implementation study in advanced HIV (98). Diagnosis of the measurement problem first: antigen load tracks fungal burden, so the same test performs differently by host and by assay. In advanced HIV the better assays reached sensitivity (in words: the share of proven cases detected) of 91.3% (galactomannan EIA) and 90.4% (lateral-flow) with specificity (in words: the share of non-cases correctly cleared) of 90.9% and 92.3%, while an older enzyme immunoassay managed only 67.3%/96.2% on the same samples. In HIV-negative patients sensitivity collapsed to 19% at specificity 100%, rising only to 45% in immunocompromised multiorgan disease. MEASUREMENT ACCURACY — PARTIAL: believe a positive; do not trust a negative outside advanced HIV, and name the assay before quoting a number.

MeSH: Adult · Antigens, Fungal · Female · HIV Infections · HIV-1 · Histoplasma · Histoplasmosis · Humans · Immunoenzyme Techniques · Male · Mexico · Middle Aged · Prospective Studies · Sensitivity and Specificity · Young Adult · Retrospective Studies · Brazil · Immunocompromised Host · Predictive Value of Tests · Suriname · AIDS-Related Opportunistic Infections · Immunoassay

Cards (4)

Card 1 — In 415 people with HIV and suspected disseminated histoplasmosis in Mexico, urine antigen sensitivity (in words: the share of proven cases detected) ranged from 67.3% for one enzyme immunoassay to 91.3% and 90.4% for a galactomannan assay and a lateral-flow assay, with specificity 90.9–96.2% (2021 study)

Study: Prospective multicentre diagnostic accuracy study, N = 415 enrolled (391 urine samples analysed)

Population: Adults living with HIV with suspected progressive disseminated histoplasmosis at ten Mexican hospitals; 108 (26%) had proven disease by culture or histopathology. Sensitivity and specificity are labelled in words in this pack's balance at first occurrence.

Summary: In 415 people with HIV and suspected disseminated histoplasmosis in Mexico, urine antigen sensitivity (in words: the share of proven cases detected) ranged from 67.3% for one enzyme immunoassay to 91.3% and 90.4% for a galactomannan assay and a lateral-flow assay, with specificity 90.9–96.2% (2021 study)

Result: Among 391 urine samples: IMMY ALPHA EIA sensitivity 67.3% (95% CI 57.4–76.2) and specificity 96.2% (93.2–98.0); Clarus galactomannan EIA sensitivity 91.3% (84.2–96.0) and specificity 90.9% (87.0–94.0); MiraVista urine antigen lateral-flow assay sensitivity 90.4% (83.0–95.3) and specificity 92.3% (88.6–95.1).

Watch out: Assay choice changes sensitivity by 24 percentage points within the same urine samples — 'Histoplasma antigen' is not one test, and the weakest assay here would miss a third of proven cases.

Source: Martínez-Gamboa A, Niembro-Ortega MD, Torres-González P et al.. Diagnostic accuracy of antigen detection in urine and molecular assays testing in different clinical samples for the diagnosis of progressive disseminated histoplasmosis in patients living with HIV/AIDS: A prospective multicenter study in Mexico. PLoS neglected tropical diseases. 2021. PMID: 33684128. Registry ID: not stated in the record. MeSH: Adult · Antigens, Fungal · Female · HIV Infections · HIV-1 · Histoplasma · Histoplasmosis · Humans · Immunoenzyme Techniques · Male · Mexico · Middle Aged · Prospective Studies · Sensitivity and Specificity · Young Adult

Card 2 — In 346 HIV-negative patients in Brazil, urine Histoplasma antigen sensitivity was only 19% (specificity 100%), rising to 45% in immunocompromised patients with multiorgan involvement (2026 cohort)

Study: Retrospective diagnostic accuracy cohort, N = 346

Population: HIV-negative patients in a Brazilian hospital whose urine was tested with a Histoplasma antigen enzyme immunoassay between 2022 and 2025; histoplasmosis was diagnosed in 43 (12%), of whom 16 (37%) were immunocompromised and 14 (33%) had disseminated disease.

Summary: In 346 HIV-negative patients in Brazil, urine Histoplasma antigen sensitivity was only 19% (specificity 100%), rising to 45% in immunocompromised patients with multiorgan involvement (2026 cohort)

Result: The assay was positive in 8 of 43 cases: sensitivity 19% and specificity 100%, with positive predictive value 100% and negative predictive value 90%. Sensitivity rose to 45% in immunocompromised patients with multiorgan involvement, and immunocompromised status independently predicted a positive test (p = 0.008).

Watch out: The mirror image of the HIV data: outside advanced HIV, a negative urine antigen cannot exclude histoplasmosis — most cases in this cohort were missed by the test.

Source: Nobrega de Almeida J, Harb Roca T, Dos Anjos Laurentis de Souza Campos D et al.. Histoplasma Urinary Antigen for the Diagnosis Histoplasmosis in Non-HIV Individuals. Mycoses. 2026. PMID: 42087626. Registry ID: not stated in the record. MeSH: Humans · Histoplasmosis · Antigens, Fungal · Female · Histoplasma · Retrospective Studies · Male · Sensitivity and Specificity · Adult · Brazil · Middle Aged · Immunocompromised Host · Immunoenzyme Techniques · Predictive Value of Tests

Card 3 — In 98 patients with advanced HIV in Suriname, a urine Histoplasma antigen lateral-flow assay was positive in 19 of 58 clinically classified possible disseminated cases (32.7%), and in only 55% of patients clinicians chose to treat (2024 study)

Study: Prospective diagnostic implementation study, N = 98

Population: Patients with advanced HIV in Suriname classified clinically as possible disseminated histoplasmosis (58) or controls (40); treating physicians made treatment decisions without knowing the lateral-flow result.

Summary: In 98 patients with advanced HIV in Suriname, a urine Histoplasma antigen lateral-flow assay was positive in 19 of 58 clinically classified possible disseminated cases (32.7%), and in only 55% of patients clinicians chose to treat (2024 study)

Result: The lateral-flow assay was positive in 19 of 58 possible cases (32.7%). Among patients started on treatment on clinical grounds, 55% had a positive assay; among untreated patients, 21% had a positive assay. The authors concluded that combining clinical signs with the assay improved treatment decisions and was cost-effective in their setting.

Watch out: No culture-based reference classification is reported for these patients, so this card shows field behaviour of the assay against clinical judgement — it is not a sensitivity/specificity estimate and is not pooled with the Mexican figures.

Source: Woittiez L, Vestjens S, Mawie T et al.. Improving disseminated histoplasmosis diagnosis in HIV/AIDS patients in Suriname: The role of a urine lateral flow assay. PLoS neglected tropical diseases. 2024. PMID: 38941354. Registry ID: not stated in the record. MeSH: Humans · Histoplasmosis · Male · Female · Adult · Suriname · Histoplasma · HIV Infections · Middle Aged · Antigens, Fungal · Sensitivity and Specificity · AIDS-Related Opportunistic Infections · Immunoassay

Card 4 — Synthesis — MEASUREMENT ACCURACY — PARTIAL: urine antigen is a strong rule-in test in advanced HIV and a weak rule-out test everywhere else

Study: Synthesis

Population: One prospective accuracy study in HIV (415 enrolled), one retrospective cohort in HIV-negative patients (346) and one field implementation study (98). Documented total: 859 people.

Summary: Synthesis — MEASUREMENT ACCURACY — PARTIAL: urine antigen is a strong rule-in test in advanced HIV and a weak rule-out test everywhere else

Result: With the better assays in advanced HIV, sensitivity reaches about 90% with specificity about 91–96%; with a weaker enzyme immunoassay it falls to 67%, and in HIV-negative patients to 19% (45% in immunocompromised multiorgan disease), while specificity stays at or near 100%. A positive result is trustworthy across settings; a negative result is only reassuring in advanced HIV with a high-performing assay.

Watch out: Distinct from live shelf #2963 (single high-dose liposomal amphotericin treatment of disseminated histoplasmosis): this shelf is only about detecting the disease, not treating it.

Source: Synthesis of the reports carded above; no additional source.