Ultrasound models sort adnexal masses well: IOTA simple rules and ADNEX discriminate at AUC about 0.92–0.93 — but ADNEX underestimates risk, and expert subjective assessment is still the benchmark

Shelf #10638 · Women’s health

MEASUREMENT ACCURACY — GOOD

Stamped: 2026-11-28.

Evidence published: 1990–2024.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In women with an adnexal mass, how accurately do ultrasound-based models — IOTA simple rules, IOTA logistic regression and the ADNEX model — distinguish benign from malignant tumours before surgery, compared with expert subjective assessment and the older Risk of Malignancy Index?

Balance of the evidence

MEASUREMENT ACCURACY — GOOD — Composition: 1 meta-analysis (47 studies, 19,674 tumours) plus 2 large external validations (894 and 4,905 patients). Sensitivity and specificity are labelled in words at first occurrence throughout. Discrimination is consistently strong: in the meta-analysis, sensitivity was 0.93 for subjective assessment, simple rules and LR2 alike, with specificity 0.89, 0.80 and 0.84 respectively, all ahead of the Risk of Malignancy Index on sensitivity (0.75; specificity 0.92). In external validation the ADNEX model's area under the curve was 0.92 with CA125 and 0.90 without, ahead of ROMA at 0.85 — but ADNEX, and ROMA more so, underestimated the risk of malignancy, and in the IOTA 2-step validation the lowest risk category's observed malignancy rate (0.9–1.1%) was not clearly below the 1% its label promises. MEASUREMENT ACCURACY — GOOD for discrimination, with calibration that runs low.

MeSH: Decision Support Techniques* · Diagnosis, Differential · Female · Humans · Logistic Models · Models, Biological* · Ovarian Neoplasms/diagnostic imaging,surgery · Predictive Value of Tests · Prognosis · Reproducibility of Results · Ultrasonography, Doppler, Color*

Cards (4)

Card 1 — Meta-analysis of 19,674 adnexal tumours: sensitivity 0.93 for subjective assessment, simple rules and LR2; the Risk of Malignancy Index managed only 0.75 (Meys 2016)

Study: Meta-analysis of diagnostic accuracy studies

Population: 47 prospective diagnostic studies enrolling 19,674 adnexal tumours (13,953 benign, 5,721 malignant) in women assessed preoperatively for ovarian cancer.

Summary: Meta-analysis of 19,674 adnexal tumours: sensitivity 0.93 for subjective assessment, simple rules and LR2; the Risk of Malignancy Index managed only 0.75 (Meys 2016)

Result: Pooled sensitivity (in words: the share of malignant tumours the test flags) and specificity (in words: the share of benign tumours the test clears) were: subjective assessment by experts sensitivity 0.93, specificity 0.89; simple rules with inconclusives classed as malignant sensitivity 0.93, specificity 0.80; LR2 sensitivity 0.93, specificity 0.84; Risk of Malignancy Index sensitivity 0.75, specificity 0.92. A two-step strategy — simple rules first, subjective assessment for inconclusive tumours — matched expert assessment (sensitivity 0.91, specificity 0.91).

Watch out: Simple-rules figures depend on how inconclusive scans are handled (here, counted as malignant, which buys sensitivity with specificity); expert subjective assessment is not a deployable test in centres without that expertise.

Source: Meys EM et al.. Subjective assessment versus ultrasound models to diagnose ovarian cancer: A systematic review and meta-analysis. European journal of cancer (Oxford, England : 1990). 2016. PMID: 26922169. Registry ID: not stated in the record. MeSH: Decision Support Techniques* · Diagnosis, Differential · Female · Humans · Logistic Models · Models, Biological* · Ovarian Neoplasms/diagnostic imaging,surgery · Predictive Value of Tests · Prognosis · Reproducibility of Results · Ultrasonography, Doppler, Color*

Card 2 — ADNEX external validation in 894 surgical patients: AUC 0.92 with CA125 and 0.90 without, versus 0.85 for ROMA — with risk underestimated (Landolfo 2024)

Study: External validation study

Population: 894 women with an adnexal tumour scheduled for surgery at five oncology centres and one non-oncology centre in four countries (2015–2019), 49% malignant on histology; ADNEX and ROMA compared head-to-head against histology.

Summary: ADNEX external validation in 894 surgical patients: AUC 0.92 with CA125 and 0.90 without, versus 0.85 for ROMA — with risk underestimated (Landolfo 2024)

Result: The area under the receiver operating characteristic curve was 0.92 (95% CI 0.88–0.95) for ADNEX with CA125, 0.90 (0.84–0.94) for ADNEX without CA125, and 0.85 (0.80–0.89) for ROMA. ROMA, and to a lesser extent ADNEX, underestimated the risk of malignancy; clinical utility was highest for ADNEX, and ROMA had no clinical utility at decision thresholds below 27%.

Watch out: A surgical series with 49% malignancy prevalence — far above a general clinic population — so discrimination travels better than the absolute risks, which already run low in this enriched sample.

Source: Landolfo C et al.. Comparison of the ADNEX and ROMA risk prediction models for the diagnosis of ovarian cancer: a multicentre external validation in patients who underwent surgery. British journal of cancer. 2024. PMID: 38243011. Registry ID: ClinicalTrials.gov: NCT01698632 and NCT02847832 (as stated in the record). MeSH: Humans · Female · Retrospective Studies · Ultrasonography · Ovarian Neoplasms/diagnosis,surgery,pathology* · Adnexal Diseases/diagnosis,surgery,pathology* · Algorithms · Sensitivity and Specificity · CA-125 Antigen

Card 3 — IOTA 2-step strategy in 4,905 patients: at the 10% risk threshold sensitivity 91% and specificity 85%, but the lowest category's malignancy rate was 0.9%, not clearly under 1% (Timmerman 2023)

Study: External validation study (prospective cohort)

Population: 4,905 patients with a newly detected adnexal mass in 17 centres from the prospective international IOTA5 cohort (after exclusions for data quality and follow-up status); 70% of tumours benign, 20% malignant, 10% uncertain, with histology or 1-year follow-up as reference.

Summary: IOTA 2-step strategy in 4,905 patients: at the 10% risk threshold sensitivity 91% and specificity 85%, but the lowest category's malignancy rate was 0.9%, not clearly under 1% (Timmerman 2023)

Result: Observed malignancy prevalence by IOTA 2-step category was 0.9% in the lowest group, 4%, 30% and 82% in the higher groups. At the 10% risk threshold the IOTA 2-step strategy had sensitivity 91% (95% CI 84–95%) and specificity 85% (80–88%); the parallel O-RADS lexicon figures were sensitivity 92% and specificity 80%, with a 1.1% observed malignancy rate in its lowest category.

Watch out: 10% of tumours had uncertain classification handled by imputation, and 19 of 36 centres were excluded for data quality — real-world performance in unselected centres may be weaker.

Source: Timmerman S et al.. External Validation of the Ovarian-Adnexal Reporting and Data System (O-RADS) Lexicon and the International Ovarian Tumor Analysis 2-Step Strategy to Stratify Ovarian Tumors Into O-RADS Risk Groups. JAMA oncology. 2023. PMID: 36520422. Registry ID: not stated in the record. MeSH: Adult · Female · Humans · Middle Aged · Cohort Studies · Retrospective Studies · Prospective Studies · Ultrasonography/methods · Ovarian Neoplasms/diagnostic imaging,epidemiology* · Adnexal Diseases/diagnosis,epidemiology,pathology* · Risk Factors · Sensitivity and Specificity

Card 4 — Synthesis: discrimination is good across models (AUC about 0.92); calibration underestimates risk, so a low model score is not a guarantee

Study: Synthesis

Population: One meta-analysis (19,674 tumours) and two external validations (894 and 4,905 patients).

Summary: Synthesis: discrimination is good across models (AUC about 0.92); calibration underestimates risk, so a low model score is not a guarantee

Result: Sensitivity 0.93 for the IOTA family in the meta-analysis; ADNEX AUC 0.92 with CA125 externally; IOTA 2-step sensitivity 91% / specificity 85% at the 10% threshold; risk underestimation reported for ADNEX and ROMA, and a 0.9–1.1% malignancy rate in the supposedly sub-1% lowest categories. MEASUREMENT ACCURACY — GOOD (discrimination), with low-running calibration.

Watch out: These models sort masses for triage and referral; none replaces histology, and the benign-appearing end of the scale is where the residual risk concentrates.

Source: Synthesis of the reports carded above; no additional source.