SourceMed · Shelf #10655 in the ask interface
Salivary pepsin (Peptest) for laryngopharyngeal reflux and reflux disease: pooled sensitivity 62% / specificity 74% in the meta-analysis, and study-level ranges so wide (sensitivity 27.0–93.8%) that method and threshold decide the answer
Shelf #10655 · Liver & gut
MEASUREMENT ACCURACY — PARTIAL
Stamped: 2026-11-28.
Evidence published: 2021–2025.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients with suspected laryngopharyngeal reflux or gastro-oesophageal reflux disease, how accurately does salivary pepsin measurement (the Peptest lateral-flow assay or ELISA) diagnose reflux against objective testing such as 24-hour impedance–pH monitoring?
Balance of the evidence
MEASUREMENT ACCURACY — PARTIAL — Composition: 1 diagnostic meta-analysis (16 articles; 2,401 patients and 897 controls) and 1 systematic review of methods and accuracy (38 studies; 3,075 participants). At first occurrence the accuracy pair is labelled in words: the pooled sensitivity was 62% and the pooled specificity was 74% for Peptest diagnosis of laryngopharyngeal reflux / gastro-oesophageal reflux disease, with an area under the curve of 0.70 — moderate diagnostic value at best. The methods review shows why a single pair misleads: across methods and thresholds, sensitivity ranged from 27.0% to 93.8% and, for Peptest at a threshold of 16 ng/mL or more, specificity ranged from 25.0% to 100%; repeated sampling across 24 hours improved both. MEASUREMENT ACCURACY — PARTIAL.
MeSH: Biomarkers · Diagnosis, Differential · Gastroesophageal Reflux · Humans · Laryngopharyngeal Reflux · Pepsin A · ROC Curve · Saliva
Cards (3)
Card 1 — Meta-analysis of 16 articles (2,401 patients, 897 controls): Peptest pooled sensitivity 62% / specificity 74%, AUC 0.70 for LPR and GERD (Guo 2021)
Study: Diagnostic meta-analysis
Population: 2,401 patients and 897 controls in 16 articles on salivary/sputum pepsin (Peptest) for diagnosis of laryngopharyngeal reflux and gastro-oesophageal reflux disease, searched to 26 January 2020.
Summary: Meta-analysis of 16 articles (2,401 patients, 897 controls): Peptest pooled sensitivity 62% / specificity 74%, AUC 0.70 for LPR and GERD (Guo 2021)
Result: Pooled sensitivity was 62% (95% CI 49% to 73%) and pooled specificity was 74% (95% CI 50% to 90%); the diagnostic odds ratio was 5.0 (95% CI 2 to 19) and the area under the curve 0.70 (95% CI 0.66 to 0.74). The authors conclude Peptest shows moderate diagnostic value and call for studies with standard protocols.
Watch out: The pooled specificity interval (50% to 90%) is very wide, reference standards varied between included studies, and laryngopharyngeal reflux and gastro-oesophageal reflux disease were pooled as one target.
Source: Guo Z et al.. Salivary peptest for laryngopharyngeal reflux and gastroesophageal reflux disease: A systemic review and meta-analysis. Medicine (Baltimore). 2021. PMID: 34397878. Registry ID: not stated in the record. MeSH: Biomarkers · Diagnosis, Differential · Gastroesophageal Reflux · Humans · Laryngopharyngeal Reflux · Pepsin A · ROC Curve · Saliva
Card 2 — Methods review of 38 studies (3,075 participants): salivary pepsin sensitivity ranged 27.0–93.8% by method and threshold; repeated sampling improved accuracy (Hiernaux 2025)
Study: Systematic review of diagnostic accuracy
Population: 38 studies of digestive-enzyme measurement in saliva in laryngopharyngeal reflux disease (1,461 females and 1,614 males; mean age 43.5 years); 12 studies used objective diagnosis by 24-hour hypopharyngeal–oesophageal impedance–pH testing, and 2 assessed children.
Summary: Methods review of 38 studies (3,075 participants): salivary pepsin sensitivity ranged 27.0–93.8% by method and threshold; repeated sampling improved accuracy (Hiernaux 2025)
Result: Sensitivity ranged widely (27.0–93.8%) across methods and thresholds: Peptest showed sensitivity 27.0–87.1% and specificity 25.0–100% at a threshold of 16 ng/mL or more, while ELISA showed sensitivity 20.0–93.8% and specificity 45.5–84.3% across cut-offs. Higher thresholds generally improved specificity at the expense of sensitivity, and multiple saliva measurements across the 24-hour testing period improved both sensitivity and specificity. Only 3 studies measured other enzymes, mainly bile salts.
Watch out: No pooled pair is offered because collection, storage, assay and threshold were not standardised; most studies did not use the objective impedance–pH reference standard.
Source: Hiernaux A et al.. Salivary Pepsin Measurement in Laryngopharyngeal Reflux Disease: A Systematic Review of Diagnostic Accuracy and Performance. J Voice. 2025. PMID: 40883142. Registry ID: not stated in the record. MeSH: not stated in the record
Card 3 — Synthesis
Study: Synthesis
Population: Total documented N = 3,298 participants in the meta-analysis (2,401 patients and 897 controls); the 2025 review covers 3,075 participants in 38 studies drawn from substantially the same literature, so the two totals are not additive.
Summary: Synthesis
Result: Pooled sensitivity 62% / specificity 74% (AUC 0.70) overstates the stability of the test: by method and threshold, sensitivity spans 27.0–93.8% and specificity 25.0–100%. MEASUREMENT ACCURACY — PARTIAL.
Watch out: Reflux diagnosis itself lacks a single gold standard in much of this literature; accuracy against symptom-based or endoscopic reference standards is weaker evidence than accuracy against impedance–pH testing.
Source: Synthesis of the reports carded above; no additional source.