SourceMed · Shelf #10656 in the ask interface
Anorectal manometry for dyssynergic defecation: real-world pooled sensitivity 86% / specificity 49% in cohort studies — while a structured digital rectal examination reached sensitivity 75% / specificity 87% in one 209-patient study
Shelf #10656 · Liver & gut
MEASUREMENT ACCURACY — PARTIAL
Stamped: 2026-11-28.
Evidence published: 2010–2021.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In adults with chronic constipation, how accurately do anorectal manometry and the digital rectal examination identify dyssynergic defecation against standard physiological criteria (manometry, balloon expulsion testing and colonic transit)?
Balance of the evidence
MEASUREMENT ACCURACY — PARTIAL — Composition: 1 diagnostic-accuracy meta-analysis of anorectal manometry (15 studies; 2,140 patients) and 1 prospective diagnostic study of the digital rectal examination (209 patients with chronic constipation). At first occurrence the pairs are labelled in words: in cohort studies — the real-world estimate — manometry had a summary sensitivity of 86% and a summary specificity of 49% (AUC 0.72), so it misses few cases but labels about half of non-dyssynergic patients positive. Three consecutive simulated defecation attempts raised sensitivity to 94%. The bedside comparator performed differently: digital rectal examination using two or more dyssynergia features had sensitivity 75% and specificity 87%, with a positive predictive value of 97% in a population where 87% had dyssynergic defecation. MEASUREMENT ACCURACY — PARTIAL.
MeSH: Ataxia · Constipation · Defecation · Defecography · Humans · Manometry · Rectal Diseases · Sensitivity and Specificity · Adult · Digital Rectal Examination · Fecal Incontinence · Female · Gastrointestinal Transit · Male · Middle Aged · Predictive Value of Tests · Rome
Cards (3)
Card 1 — Manometry meta-analysis (15 studies, 2,140 patients): cohort-study sensitivity 86% / specificity 49%, AUC 0.72; three defecation attempts raised sensitivity to 94% (Ortengren 2021)
Study: Diagnostic test accuracy meta-analysis
Population: 2,140 patients in 15 studies — cohort studies of chronically constipated patients and case-control studies of dyssynergic defecation or healthy controls — in a systematic review and meta-analysis of anorectal manometry accuracy.
Summary: Manometry meta-analysis (15 studies, 2,140 patients): cohort-study sensitivity 86% / specificity 49%, AUC 0.72; three defecation attempts raised sensitivity to 94% (Ortengren 2021)
Result: Across all studies the AUC was 0.78 (95% CI 0.72 to 0.82), with summary sensitivity 79% (61% to 90%) and summary specificity 64% (44% to 79%). In cohort studies only, the AUC was 0.72 (0.66 to 0.77), sensitivity 86% (64% to 95%) and specificity 49% (30% to 68%). Three consecutive simulated defecation attempts improved sensitivity to 94%; measuring complex pressure patterns did not improve real-world accuracy over anal pressure alone, and the manometry system used did not change accuracy. The authors conclude the role of manometry under the current London consensus protocol appears limited.
Watch out: Dyssynergic defecation has no independent gold standard — manometry is judged partly against criteria that include manometric patterns, and case-control designs inflate accuracy relative to cohorts.
Source: Ortengren AR et al.. Anorectal manometry to diagnose dyssynergic defecation: Systematic review and meta-analysis of diagnostic test accuracy. Neurogastroenterol Motil. 2021. PMID: 33772969. Registry ID: not stated in the record. MeSH: Ataxia · Constipation · Defecation · Defecography · Humans · Manometry · Rectal Diseases · Sensitivity and Specificity
Card 2 — Digital rectal examination in 209 constipated patients: sensitivity 75% / specificity 87% for dyssynergia, positive predictive value 97% (Tantiphlachiva 2010)
Study: Prospective diagnostic accuracy study
Population: 209 consecutive patients with chronic constipation (Rome III criteria) who all underwent digital rectal examination, anorectal manometry, balloon expulsion testing and colonic transit studies; 187 (87%) had dyssynergic defecation by standard criteria.
Summary: Digital rectal examination in 209 constipated patients: sensitivity 75% / specificity 87% for dyssynergia, positive predictive value 97% (Tantiphlachiva 2010)
Result: Dyssynergia on examination (two or more of: impaired perineal descent, paradoxical anal contraction, impaired push effort) identified 134 of the dyssynergic patients; sensitivity was 75% and specificity 87%, with a positive predictive value of 97%. The examination identified normal resting and squeeze pressures in 86% and 82% of dyssynergic patients respectively — it detected normal, but not abnormal, sphincter tone. The authors propose examination to select patients for physiological testing.
Watch out: Single-centre study in a referral population with an unusually high dyssynergia prevalence (87%), which inflates the positive predictive value; examiner skill is part of the test and was not varied.
Source: Tantiphlachiva K et al.. Digital rectal examination is a useful tool for identifying patients with dyssynergia. Clin Gastroenterol Hepatol. 2010. PMID: 20656061. Registry ID: not stated in the record. MeSH: Adult · Ataxia · Defecation · Digital Rectal Examination · Fecal Incontinence · Female · Gastrointestinal Transit · Humans · Male · Manometry · Middle Aged · Predictive Value of Tests · Rectal Diseases · Rome · Sensitivity and Specificity
Card 3 — Synthesis
Study: Synthesis
Population: Total documented N = 2,349: 2,140 patients in the manometry meta-analysis and 209 in the examination study; the study predates the meta-analysis search window overlap is not stated, so totals are presented as documented, not pooled.
Summary: Synthesis
Result: Manometry in real-world cohorts: sensitivity 86% / specificity 49% (AUC 0.72), improving in sensitivity to 94% with three defecation attempts. Structured digital rectal examination: sensitivity 75% / specificity 87% in one study. MEASUREMENT ACCURACY — PARTIAL.
Watch out: Both tests are judged against composite physiological criteria that include the tests' own family of measurements; neither accuracy estimate comes from a design with an independent reference standard.
Source: Synthesis of the reports carded above; no additional source.