SourceMed · Shelf #10688 in the ask interface
Pipelle endometrial sampling rarely gives a false positive for cancer (specificity about 98.5%) but misses roughly a quarter of cancers in the modern pooled estimate (sensitivity 77.4%)
Shelf #10688 · Women’s health
MEASUREMENT ACCURACY — PARTIAL
Stamped: 2026-11-28.
Evidence published: 2000–2023.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In women being investigated for suspected endometrial cancer, how accurately does outpatient endometrial sampling — the Pipelle device and conventional dilatation and curettage — detect endometrial carcinoma (and atypical hyperplasia) against hysterectomy histopathology?
Balance of the evidence
MEASUREMENT ACCURACY — PARTIAL — Sensitivity and specificity are labelled in words at first use here and on the cards. The 2023 bivariate meta-analysis (12 studies, 1,607 women, hysterectomy histopathology as reference) gives the Pipelle a sensitivity of 0.774 (95% CI 0.565 to 0.900) and a specificity of 0.985 (95% CI 0.927 to 0.997) for endometrial carcinoma; conventional dilatation and curettage pooled at sensitivity 0.880 with specificity 0.984, on wider intervals. The older, larger meta-analysis (39 studies, 7,914 women) reports the same asymmetry from the detection-rate side: the Pipelle found 99.6% of cancers in postmenopausal women and 91% in premenopausal women, with specificity above 98% for all devices, and a sensitivity of 81% for atypical hyperplasia. The two syntheses count different things (bivariate sensitivity against hysterectomy versus detection rates against mixed reference standards), so their headline figures are printed separately and never averaged. A negative Pipelle does not exclude cancer — roughly one cancer in four was missed in the modern pool — while a positive result is rarely wrong. MEASUREMENT ACCURACY — PARTIAL.
MeSH: Female · Humans · Sensitivity and Specificity · Cross-Sectional Studies · Endometrium · ROC Curve · Endometrial Neoplasms/diagnosis
Cards (3)
Card 1 — Pipelle: sensitivity 0.774, specificity 0.985 for endometrial cancer across 12 studies and 1,607 women (Sakna 2023)
Study: Systematic review and meta-analysis of diagnostic accuracy studies
Population: Women with clinical suspicion of endometrial carcinoma in 12 cross-sectional accuracy studies (1986–2022), each comparing an endometrial sampling test against histopathology of the hysterectomy specimen; 7 studies were at low risk of bias in all domains.
Summary: Pipelle: sensitivity 0.774, specificity 0.985 for endometrial cancer across 12 studies and 1,607 women (Sakna 2023)
Result: For the Pipelle: sensitivity 0.774 (95% CI 0.565 to 0.900), specificity 0.985 (95% CI 0.927 to 0.997), positive likelihood ratio 97.0 and negative likelihood ratio 0.241. For conventional dilatation and curettage: sensitivity 0.880 (95% CI 0.281 to 0.993), specificity 0.984 (95% CI 0.956 to 0.995). The authors graded the evidence as high certainty that both tests are accurate, while noting studies of other sampling devices were sparse.
Watch out: The sensitivity interval is wide (0.565–0.900) and the D&C estimate wider still; the pooled point values should not be quoted without their intervals.
Source: Sakna NA et al.. Diagnostic accuracy of endometrial sampling tests for detecting endometrial cancer: a systematic review and meta-analysis. BMJ open. 2023. PMID: 37355271. Registry ID: not stated in the record. MeSH: Female · Humans · Sensitivity and Specificity · Cross-Sectional Studies · Endometrium · ROC Curve · Endometrial Neoplasms/diagnosis
Card 2 — Detection rates: Pipelle found 99.6% of cancers after menopause and 91% before it, specificity above 98%, across 39 studies and 7,914 women (Dijkhuizen 2000)
Study: Meta-analysis of diagnostic accuracy studies
Population: 39 studies (1966–1999) of women undergoing endometrial sampling with results checked against dilatation and curettage, hysteroscopy and/or hysterectomy, analysed for cancer and atypical-hyperplasia detection by device and menopausal status.
Summary: Detection rates: Pipelle found 99.6% of cancers after menopause and 91% before it, specificity above 98%, across 39 studies and 7,914 women (Dijkhuizen 2000)
Result: The Pipelle was the best-performing device: detection rate for endometrial carcinoma 99.6% in postmenopausal women and 91% in premenopausal women; for atypical hyperplasia its sensitivity was 81%. The specificity of all sampling devices exceeded 98%. Sampling failure rates were also calculated per study.
Watch out: Detection rate against mixed reference standards (including D&C itself) is not the same quantity as sensitivity against hysterectomy histology; this card's 99.6% and the 2023 card's 0.774 sensitivity measure different things and must not be merged.
Source: Dijkhuizen FP et al.. The accuracy of endometrial sampling in the diagnosis of patients with endometrial carcinoma and hyperplasia: a meta-analysis. Cancer. 2000. PMID: 11042572. Registry ID: not stated in the record. MeSH: Endometrial Hyperplasia/pathology · Endometrial Neoplasms/pathology · Female · Humans · Reproducibility of Results · Specimen Handling/methods,standards
Card 3 — Synthesis: a strongly rule-in test and an incomplete rule-out — specificity about 98.5%, modern pooled sensitivity 77.4% for cancer
Study: Synthesis
Population: Two meta-analyses: 12 studies / 1,607 women (2023) and 39 studies / 7,914 women (2000); their primary-study sets may overlap and they are counted as syntheses, never as independent cohorts.
Summary: Synthesis: a strongly rule-in test and an incomplete rule-out — specificity about 98.5%, modern pooled sensitivity 77.4% for cancer
Result: Pipelle sensitivity (labelled in words) 0.774 and specificity 0.985 against hysterectomy histopathology; detection rates 99.6% (postmenopausal) and 91% (premenopausal) against mixed references; atypical-hyperplasia sensitivity 81%. MEASUREMENT ACCURACY — PARTIAL.
Watch out: Inadequate or failed samples are a real-world failure mode counted differently across the primary studies; neither pooled figure is a guarantee for an individual clinic's sampling adequacy rate.
Source: Synthesis of the reports carded above; no additional source.