Carotid duplex velocity criteria separate significant stenosis well: a peak systolic velocity of 200 cm/s or more identifies 70% stenosis with sensitivity 90% and specificity 94%
Shelf #10689 · Heart, vessels, blood pressure & clotting
MEASUREMENT ACCURACY — GOOD
Stamped: 2026-11-28.
Evidence published: 2005–2023.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients with carotid artery disease, how accurately do duplex ultrasound velocity criteria (peak systolic velocity, end-diastolic velocity and the internal-to-common carotid ratio) grade internal carotid artery stenosis against angiography or other reference imaging, at the 50% and 70% NASCET thresholds?
Balance of the evidence
MEASUREMENT ACCURACY — GOOD — Sensitivity and specificity are labelled in words at first use here and on the cards. Against angiography by the NASCET method, the classic meta-analysis found a peak systolic velocity (PSV) threshold of 130 cm/s or more gave sensitivity 98% and specificity 88% for stenosis of 50% or more, and a PSV of 200 cm/s or more gave sensitivity 90% and specificity 94% for stenosis of 70% or more. The 2022 Cochrane review (22 studies, 4,957 carotid arteries, symptomatic patients) found duplex versus angiography sensitivity 0.97 with specificity 0.70 across the 50–99% band, sensitivity 0.63 with specificity 0.99 below 50%, and sensitivity 0.91 with specificity 0.95 for occlusion. The SRU-criteria meta-analysis (9 studies, 1,738 bifurcation data points) put the area under the ROC curve at 0.93 for PSV at the 50% threshold. All three syntheses warn that performance varies materially between laboratories — the criteria are good, but they are laboratory property as much as test property. MEASUREMENT ACCURACY — GOOD.
MeSH: Blood Flow Velocity · Carotid Artery, Internal/diagnostic imaging,physiopathology · Carotid Stenosis/diagnostic imaging,physiopathology · Humans · Radiography · Sensitivity and Specificity · Ultrasonography, Doppler, Color · Ultrasonography, Doppler, Duplex
Cards (4)
Card 1 — PSV ≥130 cm/s: sensitivity 98%, specificity 88% for ≥50% stenosis; PSV ≥200 cm/s: sensitivity 90%, specificity 94% for ≥70% (Jahromi 2005)
Study: Systematic review and meta-analysis of diagnostic accuracy studies
Population: Systematic review and meta-analysis of studies (1966–2003) comparing colour duplex ultrasound criteria against angiography measured by the NASCET method, in studies of at least 10 adults, quality-assessed against the STARD criteria.
Summary: PSV ≥130 cm/s: sensitivity 98%, specificity 88% for ≥50% stenosis; PSV ≥200 cm/s: sensitivity 90%, specificity 94% for ≥70% (Jahromi 2005)
Result: A peak systolic velocity threshold of 130 cm/s or more identified angiographic stenosis of 50% or more with sensitivity 98% (95% CI 97 to 100%) and specificity 88% (95% CI 76 to 100%). For stenosis of 70% or more, a PSV of 200 cm/s or more gave sensitivity 90% (95% CI 84 to 94%) and specificity 94% (95% CI 88 to 97%). For every threshold, measurement properties varied widely between laboratories, by a clinically important amount.
Watch out: Pooled thresholds hide between-laboratory heterogeneity the authors call clinically important; a laboratory's own validated criteria take precedence over these pooled cut-offs.
Source: Jahromi AS et al.. Sensitivity and specificity of color duplex ultrasound measurement in the estimation of internal carotid artery stenosis: a systematic review and meta-analysis. Journal of vascular surgery. 2005. PMID: 15944595. Registry ID: not stated in the record. MeSH: Blood Flow Velocity · Carotid Artery, Internal/diagnostic imaging,physiopathology · Carotid Stenosis/diagnostic imaging,physiopathology · Humans · Radiography · Sensitivity and Specificity · Ultrasonography, Doppler, Color · Ultrasonography, Doppler, Duplex
Card 2 — Cochrane 2022: duplex versus angiography sensitivity 0.97 / specificity 0.70 for 50–99% stenosis; occlusion sensitivity 0.91 / specificity 0.95 (Cassola 2022)
Study: Cochrane systematic review of diagnostic accuracy studies
Population: 22 studies (4,957 carotid arteries) in symptomatic patients, comparing duplex ultrasound using validated velocity criteria against digital subtraction angiography, CT angiography or MR angiography, with stenosis graded by NASCET criteria; risk of bias varied and studies were generally of moderate to low quality.
Summary: Cochrane 2022: duplex versus angiography sensitivity 0.97 / specificity 0.70 for 50–99% stenosis; occlusion sensitivity 0.91 / specificity 0.95 (Cassola 2022)
Result: Against angiography: for stenosis under 50%, summary sensitivity 0.63 (95% CI 0.48 to 0.76) and specificity 0.99 (95% CI 0.96 to 0.99); for 50–99%, sensitivity 0.97 (95% CI 0.95 to 0.98) and specificity 0.70 (95% CI 0.67 to 0.73); for occlusion, sensitivity 0.91 (95% CI 0.81 to 0.97) and specificity 0.95 (95% CI 0.76 to 0.99). Only one study reported the 50–69% band separately, so no pooled figure exists for it.
Watch out: Symptomatic patients only, and mostly older studies against angiography; the review cautions against duplex as the sole preoperative test and notes little evidence against CTA or MRA as reference.
Source: Cassola N et al.. Duplex ultrasound for diagnosing symptomatic carotid stenosis in the extracranial segments. The Cochrane database of systematic reviews. 2022. PMID: 35815652. Registry ID: not stated in the record. MeSH: Carotid Stenosis/diagnostic imaging,surgery · Constriction, Pathologic · Humans · Magnetic Resonance Angiography · Sensitivity and Specificity · Ultrasonography, Doppler, Duplex
Card 3 — SRU consensus cut-points: PSV 125 cm/s most sensitive (96%) for 50% stenosis; PSV 230 cm/s most specific (86%) for 70% (Polak 2023)
Study: Meta-analysis of diagnostic accuracy data
Population: Meta-analysis of 9 studies (1993–2016) with individual-patient graphs of NASCET arteriographic stenosis against duplex velocities: 1,738 bifurcation data points for PSV, 1,026 for end-diastolic velocity and 775 for the internal/common carotid PSV ratio.
Summary: SRU consensus cut-points: PSV 125 cm/s most sensitive (96%) for 50% stenosis; PSV 230 cm/s most specific (86%) for 70% (Polak 2023)
Result: The highest sensitivity was 96% (95% CI 93 to 98%) for PSV of 125 cm/s at the 50% stenosis threshold, and the highest specificity 86% (95% CI 71 to 93%) for PSV of 230 cm/s at the 70% threshold. Areas under the ROC curve ranged from 0.93 (95% CI 0.92 to 0.95) for PSV at 50% down to 0.86 (95% CI 0.84 to 0.88) for end-diastolic velocity at 70%.
Watch out: Reconstructed from published individual-patient graphs rather than trial-level 2×2 tables; the six SRU cut-points trade sensitivity against specificity and none is best at both thresholds.
Source: Polak JF et al.. Accuracy of the Society of Radiologists in Ultrasound (SRU) Carotid Doppler Velocity Criteria for Grading North American Symptomatic Carotid Endarterectomy Trial (NASCET) Stenosis: A Meta-Analysis. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2023. PMID: 36527708. Registry ID: not stated in the record. MeSH: Humans · Endarterectomy, Carotid · Carotid Artery, Internal/diagnostic imaging · Constriction, Pathologic · Ultrasonography, Doppler, Duplex/methods · Carotid Stenosis/diagnostic imaging,surgery · Angiography · Sensitivity and Specificity · ROC Curve · North America · Blood Flow Velocity · Predictive Value of Tests
Card 4 — Synthesis: duplex grading is accurate at the decision thresholds (sensitivity 90–98%, specificity 88–94% in the classic pool), with laboratory-to-laboratory variation the standing caveat
Study: Synthesis
Population: Three syntheses (2005, 2022, 2023) whose primary-study sets overlap — counted as syntheses, never as independent cohorts.
Summary: Synthesis: duplex grading is accurate at the decision thresholds (sensitivity 90–98%, specificity 88–94% in the classic pool), with laboratory-to-laboratory variation the standing caveat
Result: PSV ≥130 cm/s: sensitivity 98%, specificity 88% (≥50% stenosis); PSV ≥200 cm/s: sensitivity 90%, specificity 94% (≥70%); Cochrane symptomatic-patient pool: sensitivity 0.97 / specificity 0.70 for the 50–99% band and sensitivity 0.91 / specificity 0.95 for occlusion. MEASUREMENT ACCURACY — GOOD.
Watch out: All carded syntheses measure duplex against an anatomical reference; none of them validates duplex as the only test before revascularisation, and the Cochrane review explicitly cautions against that use.
Source: Synthesis of the reports carded above; no additional source.