SourceMed · Shelf #10717 in the ask interface

Cheatham-Platinum stents for coarctation of the aorta (COAST and COAST II): obstruction relief sustained to 5 years, antihypertensive use down from 53% to 29% — but stent fractures reached 24.4% and reintervention 21.3% by late follow-up in single-arm trials

Shelf #10717 · Heart, vessels, blood pressure & clotting

POSSIBLE

Stamped: 2026-11-28.

Evidence published: 2015–2021.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In children and adults with native or recurrent coarctation of the aorta, do Cheatham-Platinum stents (bare metal in COAST, covered in COAST II) relieve the obstruction durably and safely over up to 5 years?

Balance of the evidence

POSSIBLE — Composition: 2 prospective multicentre single-arm trials, documented total N = 248 (COAST 121 enrolled, 105 treated in the 2-year report; COAST II 127). The Cheatham-Platinum stent (the tested device is named because stent performance is device-specific) relieved the arm–leg blood-pressure gradient immediately, with sustained improvement to 2 years and falling antihypertensive use — from 53% of patients at 1 month to 42% at 12 months and 29% at 48–60 months. The late ledger is the caution: cumulative stent fractures rose from 0% immediately to 2.9% at 12 months and 24.4% at late follow-up, cumulative reintervention reached 21.3%, and aortic aneurysms reached a cumulative incidence of 6.3% (in the 2-year report, 6 aneurysms, 5 treated with a covered stent). No fracture caused loss of stent integrity, embolisation, aortic wall injury or reobstruction in the 2-year report, and covered stents appeared to protect partly against fracture but not completely against late aneurysm. With no surgical or balloon-angioplasty comparator in either trial, this shows what the device does in selected patients, not how it compares with the alternatives. POSSIBLE.

MeSH: Adult · Aortic Dissection / etiology · Angioplasty, Balloon / instrumentation · Antihypertensive Agents / therapeutic use · Aorta / injuries · Aortic Aneurysm / etiology · Aortic Coarctation / diagnostic imaging, therapy · Aortography · Cardiac Catheterization / adverse effects · Child · Equipment Failure · Femoral Artery / injuries · Follow-Up Studies · Foreign-Body Migration / epidemiology, etiology · Hemodynamics · Humans · Hypertension / complications, drug therapy · Platinum · Prospective Studies · Reoperation · Stents / adverse effects · Treatment Outcome

Cards (3)

Card 1 — COAST at 2 years: gradient relief sustained in 104 implanted patients, 6 aortic aneurysms, stent fractures in 11 patients by 2 years (Meadows 2015)

Study: Prospective single-arm multicentre device trial (2-year report)

Population: 105 patients with native or recurrent coarctation of the aorta undergoing attempted Cheatham-Platinum stent implantation (104 successes) in the prospective multicentre COAST trial, followed to 2 years.

Summary: COAST at 2 years: gradient relief sustained in 104 implanted patients, 6 aortic aneurysms, stent fractures in 11 patients by 2 years (Meadows 2015)

Result: There were no procedural deaths, serious adverse events or surgical interventions. All patients had immediate reduction in upper- to lower-extremity blood-pressure difference, sustained to 2 years; hypertension rates and medication use fell from baseline to 12 months and were largely unchanged at 2 years. Six aortic aneurysms were identified (5 treated successfully with covered stent placement, 1 resolved without intervention). Stent fractures were noted in 2 patients at 1 year and 11 at 2 years, with progression, but no fracture caused loss of stent integrity, embolisation, aortic wall injury or reobstruction; larger stent diameter was the only correlate. Nine reinterventions occurred in the first 2 years and 10 more after 2 years.

Watch out: Single-arm against surgical performance goals, not against surgery or balloon angioplasty; aneurysm and fracture counts grew with every year of follow-up, so 2-year safety understates the late burden.

Source: Meadows J et al.. Intermediate Outcomes in the Prospective, Multicenter Coarctation of the Aorta Stent Trial (COAST). Circulation. 2015. PMID: 25869198. Registry ID: NCT00552812 (stated in the record). MeSH: Adult · Aortic Dissection / etiology · Angioplasty, Balloon / instrumentation · Antihypertensive Agents / therapeutic use · Aorta / injuries · Aortic Aneurysm / etiology · Aortic Coarctation / diagnostic imaging, therapy · Aortography · Cardiac Catheterization / adverse effects · Child · Equipment Failure · Femoral Artery / injuries · Follow-Up Studies · Foreign-Body Migration / epidemiology, etiology · Hemodynamics · Humans · Hypertension / complications, drug therapy · Platinum · Prospective Studies · Reoperation · Stents / adverse effects · Treatment Outcome

Card 2 — COAST + COAST II to 5 years: medication use 53% → 29%, but fractures 24.4% and reintervention 21.3% at late follow-up (Holzer 2021)

Study: Prospective single-arm multicentre device trials (combined long-term report)

Population: 248 patients across COAST (bare Cheatham-Platinum stent, n=121) and COAST II (covered Cheatham-Platinum stent for prevention or treatment of aortic wall injury, n=127), with late follow-up at 48–60 months.

Summary: COAST + COAST II to 5 years: medication use 53% → 29%, but fractures 24.4% and reintervention 21.3% at late follow-up (Holzer 2021)

Result: Antihypertensive medication use fell from 53% immediately post-implant to 42% at 12 months and 29% at late follow-up. Cumulative stent fracture incidence was 0% immediately, 2.9% at 12 months and 24.4% late (predictors: age under 18, male sex, minimum stent diameter ≥12 mm, bare-metal stent). Cumulative reintervention was 1.6%, 5.1% and 21.3% at the same time points. Thirteen patients had aortic aneurysms, a cumulative incidence of 6.3% late. Covered stents appeared to confer some protection from fracture but not complete protection from late aneurysm formation.

Watch out: The combined report pools a bare-stent trial and a covered-stent trial run for partly different indications (COAST II included treatment of existing wall injury); late follow-up was incomplete by design, so late percentages are cumulative-incidence estimates.

Source: Holzer RJ et al.. Long-Term Outcomes of the Coarctation of the Aorta Stent Trials. Circulation. Cardiovascular interventions. 2021. PMID: 34039015. Registry ID: NCT00552812 and NCT01278303 (stated in the record). MeSH: Adolescent · Aorta · Aortic Aneurysm · Aortic Coarctation / diagnostic imaging, surgery · Humans · Male · Stents · Treatment Outcome

Card 3 — Synthesis: durable gradient relief from CP stents, bought with a one-in-five late reintervention rate and a one-in-four late fracture rate

Study: Synthesis

Population: Two single-arm trials (248 patients enrolled; 105 treated in the COAST 2-year report).

Summary: Synthesis: durable gradient relief from CP stents, bought with a one-in-five late reintervention rate and a one-in-four late fracture rate

Result: Obstruction relief and falling blood-pressure medication use persisted to 5 years (53% → 29% on antihypertensives). Against that: stent fractures 24.4%, reintervention 21.3% and aneurysms 6.3% cumulative by late follow-up. POSSIBLE.

Watch out: No randomised comparison with surgery or balloon angioplasty exists in this record; growing children need re-expansion, which is part of — not separate from — the reintervention count.

Source: Synthesis of the reports carded above; no additional source.