SourceMed · Shelf #10720 in the ask interface

Transapical NeoChord repair for degenerative mitral regurgitation: device success 94% at 30 days falling to 78% at 5 years in a 100-patient cohort — and severe regurgitation recurred by 5 years in 63% of patients with unfavourable anatomy versus 14% with favourable anatomy

Shelf #10720 · Heart, vessels, blood pressure & clotting

MAYBE (weak evidence)

Stamped: 2026-11-28.

Evidence published: 2021–2023.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with severe degenerative mitral regurgitation from leaflet prolapse or flail, what does transapical off-pump beating-heart repair with the NeoChord DS1000 system (the tested device, NeoChord, St. Louis Park, MN — named because the results are device-specific) achieve on procedural success, durability and reintervention, and how much does valve anatomy decide the result?

Balance of the evidence

MAYBE (weak evidence) — Composition: 1 single-centre prospective cohort with 5-year follow-up (100 patients) and 1 systematic review of 6 early studies (249 patients, overlapping the founding series and never added to the cohort total); no randomised trial and no concurrent surgical comparator exist in this record. In the 100-patient cohort, technical success was 98% and procedural success 94%, 30-day mortality was 2%, and device success fell from 94% at 30 days to 92% at 1 year and 78% at 5 years; 5-year survival was 83%. Anatomy was the dividing line: cumulative severe mitral regurgitation recurrence at 5 years was 14% (95% CI 6.5 to 22.8) with favourable anatomy versus 63% (95% CI 39.7 to 86.2) with unfavourable anatomy, and reintervention 14.7% versus 43.4%. The systematic review of the earliest experience (249 patients, 97.6% with severe regurgitation) found operative success in 96.8%, no intraoperative mortality, intraoperative arrhythmia in 2.4% and significant bleeding in 3.2%. This is a feasibility-and-selection story from uncontrolled series: the procedure can work durably in well-chosen valves, and the evidence cannot say how it compares with conventional surgical repair. MAYBE (weak evidence).

MeSH: Humans · Aged · Mitral Valve Insufficiency / diagnostic imaging, surgery, etiology · Mitral Valve / diagnostic imaging, surgery · Heart Valve Prosthesis Implantation · Retrospective Studies · Treatment Outcome

Cards (3)

Card 1 — Padua cohort (100 patients, 5 years): device success 94% at 30 days, 78% at 5 years; severe MR recurrence 14% favourable versus 63% unfavourable anatomy (D'Onofrio 2023)

Study: Prospective single-centre cohort (retrospective analysis)

Population: 100 consecutive patients undergoing transapical off-pump neochord implantation for severe symptomatic degenerative mitral regurgitation (leaflet prolapse/flail) at one institution, 2013–2016; 81% had favourable anatomy and 19% unfavourable anatomy by the extent and severity of valve disease; median age 66 years, median EuroSCORE II 1.4%.

Summary: Padua cohort (100 patients, 5 years): device success 94% at 30 days, 78% at 5 years; severe MR recurrence 14% favourable versus 63% unfavourable anatomy (D'Onofrio 2023)

Result: Technical success was 98% and procedural success 94%; 30-day mortality was 2%. Device success was 94% at 30 days, 92% at 1 year and 78% at 5 years; patient success at 1 year was 92%. Median follow-up was 5.1 years and 5-year survival 83%, with no survival difference by anatomy. Cumulative severe mitral regurgitation recurrence at 5 years was 14% (95% CI 6.5 to 22.8) in favourable anatomy versus 63% (95% CI 39.7 to 86.2) in unfavourable anatomy (P<0.001), and reintervention was 14.7% versus 43.4% (P<0.001).

Watch out: Single centre and single arm from the programme that developed the technique; 'favourable anatomy' is the investigators' own classification, so the 14% versus 63% split is a selection rule awaiting external validation.

Source: D'Onofrio A et al.. Outcomes of transapical mitral valve repair with neochordae implantation. The Journal of thoracic and cardiovascular surgery. 2023. PMID: 35624055. Registry ID: not stated in the record. MeSH: Humans · Aged · Mitral Valve Insufficiency / diagnostic imaging, surgery, etiology · Mitral Valve / diagnostic imaging, surgery · Heart Valve Prosthesis Implantation · Retrospective Studies · Treatment Outcome

Card 2 — Systematic review of the early NeoChord experience: operative success 96.8% across 249 patients in 6 studies (Ahmed 2021)

Study: Systematic review of uncontrolled series

Population: Systematic review of all published human series of isolated mitral valve repair with the NeoChord DS1000 device — 6 studies, 249 patients, 97.6% with severe mitral regurgitation (overlapping the founding single-centre series).

Summary: Systematic review of the early NeoChord experience: operative success 96.8% across 249 patients in 6 studies (Ahmed 2021)

Result: Operative success was achieved in 241 of 249 patients (96.8%). No intraoperative mortality was reported. Intraoperative arrhythmia occurred in 6 patients (2.4%) and significant bleeding in 8 (3.2%). The review's own conclusion was that the procedure appears promising in selected cases while more evidence is awaited.

Watch out: Short-horizon perioperative outcomes only, from small early series with publication bias likely; it cannot speak to durability, which is where the 5-year cohort shows the anatomy-dependent split.

Source: Ahmed A et al.. Transapical off-pump mitral valve repair with NeoChord implantation: A systematic review. Journal of cardiac surgery. 2021. PMID: 33476478. Registry ID: not stated in the record. MeSH: Heart Valve Prosthesis Implantation · Humans · Mitral Valve / surgery · Mitral Valve Insufficiency / surgery · Mitral Valve Prolapse / surgery · Treatment Outcome

Card 3 — Synthesis: feasible and durable in favourable anatomy, fragile in unfavourable anatomy — and never compared with surgical repair

Study: Synthesis

Population: One 100-patient 5-year cohort plus a 249-patient systematic review of overlapping early series (counted once: the cohort is the documented base).

Summary: Synthesis: feasible and durable in favourable anatomy, fragile in unfavourable anatomy — and never compared with surgical repair

Result: Procedural success about 94–97% and 30-day mortality 2% in the cohort; device success decaying to 78% at 5 years, driven by anatomy (severe regurgitation recurrence 14% versus 63%). MAYBE (weak evidence).

Watch out: Conventional surgical mitral repair — the standard this device must beat or match — appears nowhere in this record as a comparator; all durability claims are against the patient's own baseline.

Source: Synthesis of the reports carded above; no additional source.