SourceMed · Shelf #10722 in the ask interface
Sutureless and rapid-deployment aortic valves versus conventional stented bioprostheses: haemodynamics matched at 1 year in the 819-patient PERSIST-AVR trial, cross-clamp time fell by about 13 minutes with rapid deployment in CADENCE-MIS — paid for with more paravalvular leak there and more pacemakers in the PERSIST-AVR ministernotomy analysis
Shelf #10722 · Heart, vessels, blood pressure & clotting
POSSIBLE
Stamped: 2026-11-28.
Evidence published: 2016–2022.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients undergoing surgical aortic valve replacement with a bioprosthesis, do sutureless (Perceval) or rapid-deployment (Edwards Intuity) valves match conventional sutured stented bioprostheses on haemodynamics and early outcomes — and what do they cost in paravalvular leak, platelet drop and pacemaker implantation? The tested products are named because valve performance is device-specific: Perceval (sutureless) and the Edwards Intuity rapid-deployment valve, as published in the trial records.
Balance of the evidence
POSSIBLE — Composition: 2 randomised trials, documented total N = 919 (PERSIST-AVR 819 per-protocol; CADENCE-MIS 100). In PERSIST-AVR, 1-year haemodynamics were comparable between the Perceval sutureless valve and stented valves (site-reported mean gradient 12.1±6.2 versus 11.5±4.6 mmHg; core-lab subgroup mean gradient 12.8±5.7 versus 13.4±7.7 mmHg; effective orifice area 1.3±0.4 versus 1.4±0.4 cm²), and the trial's main report found non-inferiority for major cardiovascular and cerebral events at 1 year, as summarised in the haemodynamic report. In its isolated-AVR ministernotomy/full-sternotomy sub-analysis (285 sutureless versus 293 stented), the sutureless arm had lower 1-year major events (5.2% versus 10.8%), stroke (1.0% versus 5.4%) and new atrial fibrillation (4.2% versus 11.4%) but a higher pacemaker rate (11% versus 1.6%); a platelet analysis found a larger transient platelet fall with Perceval (46% versus 32%) with no difference in transfusion, bleeding or stroke. In CADENCE-MIS, rapid-deployment Intuity via ministernotomy cut cross-clamp time (41.3±20.3 versus 54.0±20.3 minutes; P<0.001) and gave lower 1-year peak gradients (16.9±5.3 versus 21.9±8.6 mmHg; P=0.033) and larger orifice area (1.9±0.5 versus 1.7±0.4 cm²; P=0.047), with similar clinical outcomes — but significantly more paravalvular leaks (P=0.027). Faster implantation and matched haemodynamics are real; the leak and pacemaker prices are equally real, and durability beyond 1 year is untested in these records. POSSIBLE.
Cards (5)
Card 1 — PERSIST-AVR core-lab report (819 randomised): 1-year gradients and orifice area comparable for Perceval sutureless versus stented valves (Fischlein 2022)
Study: Randomised trial (core-lab haemodynamic report)
Population: 819 patients randomised to the Perceval sutureless bioprosthesis (407) or a stented sutured bioprosthesis (412) for aortic valve replacement, isolated or combined; a subgroup (71 sutureless, 82 stented) had core-laboratory echocardiography at 1 year.
Summary: PERSIST-AVR core-lab report (819 randomised): 1-year gradients and orifice area comparable for Perceval sutureless versus stented valves (Fischlein 2022)
Result: Site-reported 1-year mean gradients were 12.1±6.2 (sutureless) versus 11.5±4.6 mmHg (stented) and peak gradients 21.3±11.4 versus 22.0±8.9 mmHg; the core-lab subgroup confirmed comparable performance (mean 12.8±5.7 versus 13.4±7.7 mmHg; peak 21.5±9.1 versus 23.0±13.0 mmHg). Effective orifice area at 1 year was 1.3±0.4 versus 1.4±0.4 cm². Freedom from paravalvular leak in the core-lab subgroup was 91.3% (sutureless) versus 82.3% (stented), with mild leak in 4.3% versus 12.9%. The report states the parent trial showed non-inferiority of the sutureless valve for major cardiovascular and cerebral events at 1 year.
Watch out: This is the haemodynamic report of the trial, and the core-lab subgroup is 153 of 819 patients; the non-inferiority statement for clinical events is the report's summary of the parent trial, not data tabulated in this record.
Source: Fischlein T et al.. Hemodynamic Performance of Sutureless vs. Conventional Bioprostheses for Aortic Valve Replacement: The 1-Year Core-Lab Results of the Randomized PERSIST-AVR Trial. Frontiers in cardiovascular medicine. 2022. PMID: 35252408. Registry ID: not stated in the record. MeSH: none listed in the record
Card 2 — PERSIST-AVR isolated-AVR sub-analysis (578 patients): fewer major events, stroke and new atrial fibrillation with Perceval — but pacemakers 11% versus 1.6% (Fischlein 2022)
Study: Randomised trial sub-analysis (same trial as the card above — not new patients)
Population: Sub-analysis of PERSIST-AVR restricted to isolated surgical AVR: 285 patients implanted with Perceval (67% via ministernotomy) and 293 with stented valves (65% via ministernotomy), within the 819-patient per-protocol trial population.
Summary: PERSIST-AVR isolated-AVR sub-analysis (578 patients): fewer major events, stroke and new atrial fibrillation with Perceval — but pacemakers 11% versus 1.6% (Fischlein 2022)
Result: Sutureless implantation significantly reduced surgical times in both access approaches. At 1 year in this sub-analysis, the sutureless group had lower major adverse cardiovascular and cerebral events (5.2% versus 10.8%), stroke (1.0% versus 5.4%), new-onset atrial fibrillation (4.2% versus 11.4%) and rehospitalisation, but a higher permanent pacemaker implantation rate (11% versus 1.6%). In-hospital results did not differ between valve types in the full-sternotomy stratum.
Watch out: A sub-analysis slicing one trial by access route: the event advantages were not the trial's primary endpoint, the pacemaker penalty (11% versus 1.6%) is large, and these 578 patients are a subset of the 819 already counted.
Source: Fischlein T et al.. Randomized controlled trial between conventional versus sutureless bioprostheses for aortic valve replacement: Impact of mini and full sternotomy access at 1-year follow-up. International journal of cardiology. 2022. PMID: 35944771. Registry ID: not stated in the record. MeSH: Aortic Valve / surgery · Aortic Valve Stenosis / surgery · Atrial Fibrillation / diagnosis, surgery · Bioprosthesis · Follow-Up Studies · Heart Valve Prosthesis · Heart Valve Prosthesis Implantation / methods · Humans · Prosthesis Design · Retrospective Studies · Sternotomy / methods · Treatment Outcome
Card 3 — PERSIST-AVR platelet analysis: platelet count fell 46% after Perceval versus 32% after stented valves — transient, with no difference in bleeding or transfusion (Lorusso 2021)
Study: Randomised trial ad hoc analysis (same trial — not new patients)
Population: Patients randomised within PERSIST-AVR (March 2016 to September 2018) to the Perceval sutureless bioprosthesis or a standard stented bioprosthesis; ad hoc analysis of perioperative platelet counts and their clinical correlates (analysis population drawn from the same 819-patient trial).
Summary: PERSIST-AVR platelet analysis: platelet count fell 46% after Perceval versus 32% after stented valves — transient, with no difference in bleeding or transfusion (Lorusso 2021)
Result: The Perceval group showed a higher platelet reduction than controls (46% versus 32%); the fall was transient in both groups, with slow recovery by hospital discharge. There were no between-group differences in transfusion need, blood loss, major bleeding or stroke, and the platelet decline did not affect clinical outcomes.
Watch out: An ad hoc analysis of a laboratory phenomenon whose mechanism the authors call speculative; reassuring on bleeding, but it adds a haematological cost to the sutureless ledger.
Source: Lorusso R et al.. Perioperative platelet reduction after sutureless or stented valve implantation: results from the PERSIST-AVR controlled randomized trial. European journal of cardio-thoracic surgery. 2021. PMID: 34118150. Registry ID: NCT02673697 (stated in the record). MeSH: Aortic Valve / surgery · Aortic Valve Stenosis / surgery · Bioprosthesis / adverse effects · Heart Valve Prosthesis / adverse effects · Heart Valve Prosthesis Implantation / adverse effects, methods · Humans · Prospective Studies · Prosthesis Design · Sutureless Surgical Procedures / adverse effects, methods · Treatment Outcome
Card 4 — CADENCE-MIS (100 randomised): rapid-deployment Intuity via ministernotomy cut cross-clamp time by ~13 minutes and improved 1-year haemodynamics — with significantly more paravalvular leaks (Borger 2016)
Study: Randomised trial
Population: 100 patients with aortic stenosis randomised to minimally invasive rapid-deployment AVR with the Edwards Intuity valve via upper hemisternotomy, or conventional AVR via full sternotomy with a standard stented bioprosthesis; patients needing concomitant procedures or with ejection fraction below 25% were excluded.
Summary: CADENCE-MIS (100 randomised): rapid-deployment Intuity via ministernotomy cut cross-clamp time by ~13 minutes and improved 1-year haemodynamics — with significantly more paravalvular leaks (Borger 2016)
Result: Technical success was 94% in the rapid-deployment arm. Cross-clamp time was 41.3±20.3 versus 54.0±20.3 minutes (P<0.001). Clinical and functional outcomes were similar at 30 days and 1 year, with similarly sized valves implanted (22.9±2.1 versus 23.0±2.1 mm). At 1 year the rapid-deployment group had lower peak gradients (16.9±5.3 versus 21.9±8.6 mmHg; P=0.033), a trend to lower mean gradients (9.1±2.9 versus 11.5±4.3 mmHg; P=0.082) and a larger effective orifice area (1.9±0.5 versus 1.7±0.4 cm²; P=0.047) — but paravalvular leaks were significantly more common (P=0.027).
Watch out: The comparison bundles two changes at once — valve type and surgical access (ministernotomy versus full sternotomy) — so the haemodynamic edge cannot be credited to the valve alone; 100 patients and 1 year cannot address durability.
Source: Borger MA et al.. Haemodynamic benefits of rapid deployment aortic valve replacement via a minimally invasive approach: 1-year results of a prospective multicentre randomized controlled trial. European journal of cardio-thoracic surgery. 2016. PMID: 26935407. Registry ID: not stated in the record. MeSH: Aged · Aortic Valve Stenosis / surgery · Bioprosthesis · Female · Heart Valve Prosthesis · Heart Valve Prosthesis Implantation / instrumentation, methods · Hemodynamics · Humans · Male · Minimally Invasive Surgical Procedures / methods · Prospective Studies
Card 5 — Synthesis: implantation is faster and 1-year haemodynamics match conventional valves; the prices are paravalvular leak (Intuity) and pacemakers (Perceval)
Study: Synthesis
Population: Two randomised trials totalling 919 patients (PERSIST-AVR 819, with two further reports on the same patients; CADENCE-MIS 100).
Summary: Synthesis: implantation is faster and 1-year haemodynamics match conventional valves; the prices are paravalvular leak (Intuity) and pacemakers (Perceval)
Result: Haemodynamics at 1 year: comparable (PERSIST-AVR) to modestly better (CADENCE-MIS: peak gradient 16.9 versus 21.9 mmHg). Cross-clamp time −12.7 minutes (CADENCE-MIS). Costs: paravalvular leaks significantly more common with rapid deployment; pacemaker implantation 11% versus 1.6% in the PERSIST-AVR isolated-AVR sub-analysis; transient platelet fall 46% versus 32% with Perceval. POSSIBLE.
Watch out: All follow-up here is 1 year; sutureless and rapid-deployment valves are implanted in younger surgical patients than TAVR populations, so durability over 10+ years is the open question these records cannot answer.
Source: Synthesis of the reports carded above; no additional source.