SourceMed · Shelf #10739 in the ask interface
Cryptococcal antigen testing is highly accurate: in HIV-associated meningitis, serum antigen sensitivity 99.7% and specificity 94.1%, CSF antigen sensitivity 98.8% and specificity 99.3% against culture
Shelf #10739 · Brain, stroke & mind
MEASUREMENT ACCURACY — GOOD
Stamped: 2026-11-28.
Evidence published: 2015–2021.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients with suspected cryptococcosis — above all adults living with HIV with suspected cryptococcal meningitis — how accurately does cryptococcal antigen detection (lateral flow assay and antigen tests in serum and cerebrospinal fluid) identify disease against culture and reference standards, in sensitivity and specificity (each labelled in words)?
Balance of the evidence
MEASUREMENT ACCURACY — GOOD — Composition: three meta-analyses whose primary-study sets overlap — counted as syntheses, never as independent cohorts. In adults living with HIV with suspected cryptococcal meningitis (11 studies, 3,600 participants, culture reference), summary sensitivity and specificity were 99.7% (97.4–100) and 94.1% (88.3–98.1) for serum antigen, and 98.8% (96.2–99.6) and 99.3% (96.7–99.9) for CSF antigen, with 98% agreement between CSF antigen and CSF culture. The lateral-flow-specific pools agree: serum sensitivity 97.6% and specificity 98.1%, CSF sensitivity 98.9% and specificity 98.9% (12 studies); a third pool gives merged sensitivity and specificity of 0.98 and 0.98 in serum and 0.99 and 0.99 in CSF (15 articles, 31 fourfold tables). The one soft spot is serum specificity in the meningitis pool (94.1%) — a positive serum antigen in a symptomatic patient is strong evidence, but the CSF test is the cleaner rule-in. MEASUREMENT ACCURACY — GOOD: among the most accurate antigen tests in routine use; a negative serum CrAg in this population effectively excludes cryptococcal meningitis.
MeSH: AIDS-Related Opportunistic Infections/diagnosis · Adult · Antigens, Fungal · Cryptococcus · Diagnostic Tests, Routine · HIV · HIV Infections/complications · Humans · Meningitis, Cryptococcal/diagnosis
Cards (4)
Card 1 — In 3,600 adults living with HIV with suspected meningitis: serum CrAg sensitivity 99.7% / specificity 94.1%; CSF CrAg sensitivity 98.8% / specificity 99.3% (2021 meta-analysis)
Study: Systematic review and meta-analysis of diagnostic accuracy
Population: Systematic review and meta-analysis of 11 diagnostic accuracy studies in adults living with HIV with suspected cryptococcal meningitis, in which serum or CSF cryptococcal antigen detection and CSF fungal culture were both performed; 3,600 participants; risk of bias assessed with QUADAS-2.
Summary: In 3,600 adults living with HIV with suspected meningitis: serum CrAg sensitivity 99.7% / specificity 94.1%; CSF CrAg sensitivity 98.8% / specificity 99.3% (2021 meta-analysis)
Result: Summary sensitivity and specificity of serum CrAg were 99.7% (97.4–100) and 94.1% (88.3–98.1) respectively; summary sensitivity and specificity of CSF CrAg were 98.8% (96.2–99.6) and 99.3% (96.7–99.9). Agreement between CSF CrAg and CSF culture was 98% (97–99). The authors conclude serum CrAg negativity may rule out cryptococcal meningitis, while CSF CrAg positivity in a first episode is diagnostic.
Watch out: Population is adults living with HIV with meningitis symptoms; accuracy in non-HIV or asymptomatic screening populations is a different question and is not pooled here.
Source: Temfack E et al.. Cryptococcal Antigen in Serum and Cerebrospinal Fluid for Detecting Cryptococcal Meningitis in Adults Living With Human Immunodeficiency Virus: Systematic Review and Meta-Analysis of Diagnostic Test Accuracy Studies. Clinical infectious diseases. 2021. PMID: 32829406. Registry ID: not stated in the record. MeSH: AIDS-Related Opportunistic Infections/diagnosis · Adult · Antigens, Fungal · Cryptococcus · Diagnostic Tests, Routine · HIV · HIV Infections/complications · Humans · Meningitis, Cryptococcal/diagnosis
Card 2 — Lateral flow assay pools: serum sensitivity 97.6% / specificity 98.1%; CSF sensitivity 98.9% / specificity 98.9% (2015 meta-analysis, 12 studies)
Study: Systematic review and meta-analysis of diagnostic accuracy
Population: Systematic review and meta-analysis of 12 studies of the cryptococcal antigen lateral flow immunoassay in serum, CSF and urine, published to September 2014, with subgroup analyses for heterogeneity.
Summary: Lateral flow assay pools: serum sensitivity 97.6% / specificity 98.1%; CSF sensitivity 98.9% / specificity 98.9% (2015 meta-analysis, 12 studies)
Result: Pooled sensitivity and specificity of the LFA in serum were 97.6% (95% CI 95.6–98.9) and 98.1% (97.4–98.6), with positive likelihood ratio 43.8 and negative likelihood ratio 0.03 and AUC 0.9968. Pooled sensitivity and specificity in CSF were 98.9% (97.9–99.5) and 98.9% (98.0–99.5).
Watch out: The record's CSF positive-likelihood-ratio line repeats the words 'in serum' — an apparent typographical slip in the abstract; only the sensitivity and specificity pair, which are stated unambiguously, are carded.
Source: Huang HR et al.. Evaluation of a new cryptococcal antigen lateral flow immunoassay in serum, cerebrospinal fluid and urine for the diagnosis of cryptococcosis: a meta-analysis and systematic review. PloS one. 2015. PMID: 25974018. Registry ID: not stated in the record. MeSH: Antigens, Fungal/blood,cerebrospinal fluid,urine · Cryptococcosis/blood,cerebrospinal fluid,diagnosis,urine · Cryptococcus/immunology · Humans · Immunoassay/methods · Sensitivity and Specificity
Card 3 — Third pool (15 articles, 31 fourfold tables): merged sensitivity and specificity 0.98 and 0.98 in serum, 0.99 and 0.99 in CSF (2020 meta-analysis)
Study: Systematic review and meta-analysis of diagnostic accuracy
Population: Systematic review of lateral flow immunochromatographic assay studies for cryptococcosis retrieved from Embase, PubMed, Web of Science and Cochrane Library to July 2019: 15 articles contributing 31 fourfold tables across specimen types.
Summary: Third pool (15 articles, 31 fourfold tables): merged sensitivity and specificity 0.98 and 0.98 in serum, 0.99 and 0.99 in CSF (2020 meta-analysis)
Result: The merged sensitivity and specificity in serum were 0.98 and 0.98 respectively, and in cerebrospinal fluid 0.99 and 0.99. Compared with urine and other samples, LFA in serum and CSF was favourable evidence for the diagnosis of cryptococcosis, with high specificity and sensitivity.
Watch out: Confidence intervals for the merged pairs are not printed in the abstract; the card claims the point estimates only, and this pool overlaps the primary studies of the other two syntheses.
Source: Xie LM et al.. Evaluation of lateral flow immunochromatographic assay for diagnostic accuracy of cryptococcosis. BMC infectious diseases. 2020. PMID: 32887568. Registry ID: not stated in the record. MeSH: Antigens, Fungal/blood,cerebrospinal fluid,urine · Cerebrospinal Fluid/microbiology · Cryptococcosis/diagnosis · Diagnostic Tests, Routine/methods · Humans · Immunoassay/methods · Sensitivity and Specificity
Card 4 — Synthesis: sensitivity 98–100% and specificity 94–99% across three overlapping pools — serum for ruling out, CSF for ruling in
Study: Synthesis
Population: Three meta-analyses (11 studies / 3,600 participants; 12 studies; 15 articles / 31 tables) with overlapping primary-study sets, counted as syntheses.
Summary: Synthesis: sensitivity 98–100% and specificity 94–99% across three overlapping pools — serum for ruling out, CSF for ruling in
Result: Serum CrAg: sensitivity 99.7% and 97.6% in the two pools that report it, specificity 94.1% and 98.1%. CSF CrAg: sensitivity 98.8–99%, specificity 98.9–99.3%. MEASUREMENT ACCURACY — GOOD.
Watch out: All three syntheses draw on substantially the same primary literature, mostly in HIV-associated meningitis; agreement between them is consistency of pooling, not three independent confirmations.
Source: Synthesis of the reports carded above; no additional source.