SourceMed · Shelf #10742 in the ask interface
Examination and ultrasound reliably tell whether a groin hernia is present (accuracy about 93–94%) but not what type it is (about 54–62%) — and ultrasound sensitivity for clinically occult hernia swings from 29% to 100% between series
Shelf #10742 · Emergency & first hours
MEASUREMENT ACCURACY — PARTIAL
Stamped: 2026-11-28.
Evidence published: 1999–2005.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients with suspected groin (inguinal/femoral) hernia, how accurately do clinical examination and ultrasound detect a hernia against surgical findings — in sensitivity and specificity (each labelled in words) — how well do they classify hernia type, and how does accuracy change when the hernia is clinically occult?
Balance of the evidence
MEASUREMENT ACCURACY — PARTIAL — Composition: four prospective surgical-correlation series (220, 41, 118 and 52 patients; no meta-analysis exists in the carded records). For the presence of a hernia the tests look strong: in 220 referred patients, clinical examination and ultrasound each reached about 93–94% total accuracy against laparoscopic findings; in 41 patients with clinically evident herniation, sensitivity and specificity were 74.5% and 96.3% for physical examination, 92.7% and 81.5% for ultrasound, and 94.5% and 96.3% for MRI. Classification is where both fail: accuracy for distinguishing lateral from medial hernia fell to 54% (examination) and 62% (ultrasound), and for hernia size to about 50–53%. The occult-hernia literature is the sharpest caution: ultrasound sensitivity was 100% with specificity 100% in one series of clinically diagnosed hernias taken to surgery, but only 29% against herniography (33% against surgical findings, specificity 100%) in patients whose examinations were normal or inconclusive — the same test, a different spectrum of patients. MEASUREMENT ACCURACY — PARTIAL: trust examination or ultrasound on whether a hernia is there when one is clinically apparent; do not trust either to type it, and do not let a negative ultrasound close the question when the examination cannot feel an occult hernia.
MeSH: Adult · Aged · Aged, 80 and over · Female · Hernia, Inguinal/classification,diagnosis,diagnostic imaging,surgery · Humans · Laparoscopy · Male · Middle Aged · Palpation · Physical Examination · Prospective Studies · Sensitivity and Specificity · Ultrasonography
Cards (5)
Card 1 — In 220 referred patients, examination and ultrasound were each about 93–94% accurate for hernia presence — but only 54% and 62% accurate for hernia type (2003)
Study: Primary prospective diagnostic accuracy study
Population: 220 consecutive patients referred for surgical management of an inguinal hernia; on admission both inguinal regions were examined clinically and by ultrasound, and all patients were operated on laparoscopically, giving intraoperative findings for both groins as the reference.
Summary: In 220 referred patients, examination and ultrasound were each about 93–94% accurate for hernia presence — but only 54% and 62% accurate for hernia type (2003)
Result: For the diagnosis of inguinal hernia, clinical and ultrasound examination yielded a high total rate of accuracy of 93% and 94% respectively. Used to differentiate lateral from medial hernia, total accuracy fell to 54% (clinical) and 62% (ultrasound); for determining hernia size it was lower still, at 50% and 53%.
Watch out: The record reports total accuracy rather than a sensitivity/specificity pair for the primary comparison; the card claims accuracy as printed and does not convert it.
Source: Kraft BM et al.. Diagnosis and classification of inguinal hernias. Surgical endoscopy. 2003. PMID: 14577028. Registry ID: not stated in the record. MeSH: Adult · Aged · Aged, 80 and over · Female · Hernia, Inguinal/classification,diagnosis,diagnostic imaging,surgery · Humans · Laparoscopy · Male · Middle Aged · Palpation · Physical Examination · Prospective Studies · Sensitivity and Specificity · Ultrasonography
Card 2 — In 41 patients (82 groins, 55 herniations at laparoscopy): examination sensitivity 74.5% / specificity 96.3%; ultrasound 92.7% / 81.5%; MRI 94.5% / 96.3% (1999)
Study: Primary prospective diagnostic accuracy study
Population: 41 patients with clinically evident inguinal herniation; 82 groins evaluated by physical examination, a standard ultrasound protocol and dynamic MRI, all imaging reviewed blind to clinical findings, with laparoscopic surgical findings as the reference in every case.
Summary: In 41 patients (82 groins, 55 herniations at laparoscopy): examination sensitivity 74.5% / specificity 96.3%; ultrasound 92.7% / 81.5%; MRI 94.5% / 96.3% (1999)
Result: Physical examination revealed 42 herniations (one false positive); ultrasound diagnosed 56 (five false positives, four false negatives); MRI diagnosed 53 (one false positive, three false negatives). Sensitivity and specificity were 74.5% and 96.3% for physical examination, 92.7% and 81.5% for ultrasound, and 94.5% and 96.3% for MRI. The authors conclude MRI is a valid tool with a high positive predictive value in clinically uncertain herniation.
Watch out: Only 41 patients, all with clinically evident herniation — a spectrum that flatters every test; the occult-hernia cards below show what happens outside it.
Source: van den Berg JC et al.. Detection of groin hernia with physical examination, ultrasound, and MRI compared with laparoscopic findings. Investigative radiology. 1999. PMID: 10587869. Registry ID: not stated in the record. MeSH: Adult · Aged · Diagnosis, Differential · Diagnostic Errors · Female · Groin/diagnostic imaging · Hernia, Inguinal/diagnosis,surgery · Humans · Laparoscopy · Magnetic Resonance Imaging · Male · Middle Aged · Physical Examination · Predictive Value of Tests · Prospective Studies · Reproducibility of Results · Ultrasonography
Card 3 — In clinically diagnosed hernias taken to surgery, ultrasound sensitivity and specificity were both 100% — including both femoral hernias (2003)
Study: Primary prospective diagnostic accuracy study
Population: 118 patients with a clinical diagnosis of groin hernia who prospectively underwent blinded ultrasound examination of the groin; 120 symptomatic groins in 118 patients proceeded to surgery, whose findings were compared with the ultrasound results.
Summary: In clinically diagnosed hernias taken to surgery, ultrasound sensitivity and specificity were both 100% — including both femoral hernias (2003)
Result: Ultrasound diagnosed 118 hernias and returned two normal examinations; surgery confirmed the same two patients to be normal — ultrasound sensitivity for all hernias was 100% with 100% specificity. Both femoral hernias in the study were correctly identified. For typing, ultrasound identified 36 of 42 direct hernias (sensitivity 86%, specificity 97%) and 72 of 74 indirect hernias (sensitivity 97%, specificity 87%).
Watch out: Every patient already carried a clinical diagnosis — this is confirmation within a positive spectrum, and its perfect pair must not be quoted for patients whose examination is negative or equivocal (see card 4).
Source: Bradley M et al.. The groin hernia - an ultrasound diagnosis? Annals of the Royal College of Surgeons of England. 2003. PMID: 12831490. Registry ID: not stated in the record. MeSH: Adult · Aged · Aged, 80 and over · Female · Groin · Hernia, Inguinal/diagnostic imaging,surgery · Humans · Male · Middle Aged · Pain/diagnostic imaging,etiology · Prospective Studies · Sensitivity and Specificity · Ultrasonography
Card 4 — In occult hernia (suggestive history, normal or inconclusive examination), ultrasound sensitivity collapsed to 29% against herniography and 33% against surgery, at specificity 90–100% (2005)
Study: Primary prospective diagnostic accuracy study
Population: 52 consecutive surgical outpatients with a history suggestive of groin hernia but a normal or inconclusive clinical examination; preliminary ultrasound by an experienced consultant radiologist blinded to the side of symptoms, followed by herniography in all and surgical exploration in some.
Summary: In occult hernia (suggestive history, normal or inconclusive examination), ultrasound sensitivity collapsed to 29% against herniography and 33% against surgery, at specificity 90–100% (2005)
Result: Ultrasound had a sensitivity of 29% and specificity of 90% compared with herniography; correlated with surgical findings, ultrasound sensitivity was 33% and specificity 100%. The authors conclude that ultrasound sensitivity for clinically occult hernia in a non-acute presentation is poor, and that patients with normal ultrasound should be considered for further investigation.
Watch out: Herniography — itself an imperfect, now rarely used test — is the main reference standard here; the card's point is the spectrum effect (100% sensitivity in card 3's spectrum versus 29–33% here), which survives either reference.
Source: Alam A et al.. The accuracy of ultrasound in the diagnosis of clinically occult groin hernias in adults. European radiology. 2005. PMID: 15986204. Registry ID: not stated in the record. MeSH: Adult · Female · Groin/diagnostic imaging · Hernia, Inguinal/diagnostic imaging · Humans · Male · Middle Aged · Radiography · Reproducibility of Results · Sensitivity and Specificity · Single-Blind Method · Ultrasonography/methods
Card 5 — Synthesis: presence — accurate (93–94% total accuracy; examination specificity 96.3%); type — little better than chance (54–62%); occult disease — ultrasound sensitivity 29–100% depending on spectrum
Study: Synthesis
Population: Four prospective series totalling 431 patients (220 + 41 + 118 + 52), each against surgical or herniographic reference standards.
Summary: Synthesis: presence — accurate (93–94% total accuracy; examination specificity 96.3%); type — little better than chance (54–62%); occult disease — ultrasound sensitivity 29–100% depending on spectrum
Result: Presence: total accuracy 93% (examination) and 94% (ultrasound); in the blinded three-way study, sensitivity/specificity 74.5%/96.3% examination, 92.7%/81.5% ultrasound, 94.5%/96.3% MRI. Type: 54–62% accuracy. Occult spectrum: ultrasound sensitivity 29–33%, against 100% in a clinically diagnosed spectrum. MEASUREMENT ACCURACY — PARTIAL.
Watch out: No meta-analysis is carded; estimates are single-centre series from 1999–2005, and the spread between them — driven by patient spectrum — is itself the shelf's main finding.
Source: Synthesis of the reports carded above; no additional source.