SourceMed · Shelf #10788 in the ask interface
Hepatitis C core antigen detects active infection nearly as well as RNA testing for the best-studied assay: pooled sensitivity (in words: the share of truly infected people the test catches) 96% and specificity (in words: the share of truly uninfected people the test clears) 99% for the Abbott ARCHITECT assay
Shelf #10788 · Liver & gut
MEASUREMENT ACCURACY — GOOD
Stamped: 2026-11-28.
Evidence published: 2016–2023.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In people being tested for hepatitis C, how accurately does hepatitis C core antigen (HCVcAg) testing identify active HCV infection against nucleic acid (RNA) testing as the reference standard — overall, and by assay?
Balance of the evidence
MEASUREMENT ACCURACY — GOOD — for the best-studied assay, with the qualifier that performance is assay-dependent. Composition: two systematic reviews with meta-analysis (44 studies of 5 assays in 2016; 46 studies and 18,116 samples for the Abbott ARCHITECT assay in 2023; the pools overlap in primary studies and are not summed). Sensitivity and specificity are labelled in words at first occurrence in the title above. For the Abbott ARCHITECT assay, the 2023 bivariate pool gives sensitivity 0.96 (95% CI 0.94–0.97) and specificity 0.99 (95% CI 0.99–1.00), closely matching the 2016 pool for the same assay (sensitivity 93.4%, specificity 98.8%). The Ortho ELISA performed similarly in 2016 (93.2% / 99.2%), but one assay was far worse (Hunan Jynda ELISA: sensitivity 59.5%, specificity 82.9%), so the GOOD grade belongs to the validated automated assays, not to core-antigen testing as a class. In 3 quantitative studies, antigen correlated closely with HCV RNA levels above 3,000 IU/mL, which is where its sensitivity is earned; at low prevalence (0.1–5%) a positive result still needs confirmation, while a negative result makes infection very unlikely. MEASUREMENT ACCURACY — GOOD: for the Abbott ARCHITECT assay, core antigen is an accurate one-step alternative to RNA testing for active hepatitis C, with accuracy falling for other assays and at very low viral loads.
MeSH: Cross-Sectional Studies · Genotype · Hepacivirus/genetics,isolation & purification · Hepatitis C/diagnosis,virology · Hepatitis C Antigens/blood · Humans · Nucleic Acid Amplification Techniques · RNA, Viral/blood · Sensitivity and Specificity
Cards (3)
Card 1 — 44 studies of 5 core-antigen assays (2016): Abbott ARCHITECT sensitivity 93.4% and specificity 98.8%; one ELISA only 59.5% and 82.9% (Freiman 2016)
Study: Systematic review and meta-analysis of diagnostic accuracy
Population: Adults and children tested for active HCV infection in 44 studies (case-control, cross-sectional, cohort or randomised designs) comparing any of 5 HCV core-antigen tests against a nucleic acid testing reference standard, with quality assessed by an adapted QUADAS-2 tool; the abstract does not state the total participant count.
Summary: 44 studies of 5 core-antigen assays (2016): Abbott ARCHITECT sensitivity 93.4% and specificity 98.8%; one ELISA only 59.5% and 82.9% (Freiman 2016)
Result: Bivariate pooled sensitivity and specificity (labelled in words: sensitivity is the share of truly infected people the test catches; specificity is the share of truly uninfected people the test clears): Abbott ARCHITECT 93.4% (95% CI 90.1–96.4%) and 98.8% (97.4–99.5%); Ortho ELISA 93.2% (81.6–97.7%) and 99.2% (87.9–100%); Hunan Jynda Bioengineering Group ELISA 59.5% (46.0–71.7%) and 82.9% (58.6–94.3%). Data were insufficient to pool the Fujirebio Lumipulse and Eiken Lumispot assays. In 3 quantitative studies using Abbott ARCHITECT, core antigen correlated closely with HCV RNA levels greater than 3,000 IU/mL. Studies of the Abbott assay were of highest quality and of the Ortho ELISA lowest; data for genotypes 4, 5 and 6 were scant.
Watch out: The class average hides a poor assay: the Jynda ELISA's sensitivity of 59.5% would miss two infections in five. Genotype coverage is thin outside genotypes 1–3, and most studies were conducted in high-resource settings.
Source: Freiman JM et al.. Hepatitis C Core Antigen Testing for Diagnosis of Hepatitis C Virus Infection: A Systematic Review and Meta-analysis. Annals of internal medicine. 2016. PMID: 27322622. Registry ID: not stated in the record. MeSH: Cross-Sectional Studies · Genotype · Hepacivirus/genetics,isolation & purification · Hepatitis C/diagnosis,virology · Hepatitis C Antigens/blood · Humans · Nucleic Acid Amplification Techniques · RNA, Viral/blood · Sensitivity and Specificity
Card 2 — 46 studies, 18,116 samples (2023): Abbott ARCHITECT core antigen sensitivity 0.96 and specificity 0.99 against RNA testing (Sepúlveda-Crespo 2023)
Study: Systematic review and meta-analysis of diagnostic accuracy
Population: 46 studies (18,116 samples) evaluating the Abbott ARCHITECT HCV Ag assay against nucleic acid amplification tests with a cut-off of 50 IU/mL or lower as the reference standard, pooled with the STATA MIDAS module under random-effects bivariate models; the review protocol was registered on PROSPERO (CRD42022337191, as stated in the record).
Summary: 46 studies, 18,116 samples (2023): Abbott ARCHITECT core antigen sensitivity 0.96 and specificity 0.99 against RNA testing (Sepúlveda-Crespo 2023)
Result: Pooled sensitivity was 0.96 (95% CI 0.94–0.97), specificity 0.99 (95% CI 0.99–1.00), positive likelihood ratio 141.81 (72.39–277.79) and negative likelihood ratio 0.04 (0.03–0.06); the area under the summary receiver operating characteristic curve was 1.00 (95% CI 0.34–1.00). At active-hepatitis-C prevalence values of 0.1%–15%, the probability that a positive test was a true positive ranged from 12% to 96%, so confirmation is needed particularly at prevalence of 5% or below; the probability that a negative test was a false negative was close to zero.
Watch out: One assay only (Abbott ARCHITECT) — this pool cannot rescue the weaker assays in the 2016 review. The summary-curve confidence interval printed in the record (0.34–1.00) is very wide, and the pool overlaps the 2016 review's primary studies, so the two reviews are corroboration, not independent replication.
Source: Sepúlveda-Crespo D et al.. Diagnostic performance of hepatitis C core antigen assay to identify active infections: A systematic review and meta-analysis. Reviews in medical virology. 2023. PMID: 36811353. Registry ID: not stated in the record. MeSH: Humans · Hepatitis C Antigens/analysis · Sensitivity and Specificity · Prospective Studies · RNA, Viral · Hepacivirus/genetics · Hepatitis C
Card 3 — Synthesis: an accurate RNA substitute where the validated automated assay is used — sensitivity 0.96 / specificity 0.99 in the largest pool
Study: Synthesis
Population: Two overlapping meta-analytic pools: 44 studies across 5 assays (2016) and 46 studies / 18,116 samples for one assay (2023).
Summary: Synthesis: an accurate RNA substitute where the validated automated assay is used — sensitivity 0.96 / specificity 0.99 in the largest pool
Result: For the Abbott ARCHITECT assay the two pools agree (sensitivity 93.4–96%, specificity about 99%), antigen tracks RNA above 3,000 IU/mL, and a negative result makes active infection very unlikely at any studied prevalence; positives at low prevalence still need confirmation, and at least one marketed ELISA is far less accurate. MEASUREMENT ACCURACY — GOOD.
Watch out: The GOOD stamp is assay-specific and is stated that way on the face; it does not extend to core-antigen testing as a class, to very-low-level viraemia, or to genotypes 4–6, where data are scant.
Source: Synthesis of the reports carded above; no additional source.