SourceMed · Shelf #10792 in the ask interface
In left bundle branch block, 'new or presumed new' tells you almost nothing about occlusion, but the Smith-modified Sgarbossa criteria do: pooled sensitivity (in words: the share of occlusions the criteria catch) 83.6% and specificity (in words: the share of non-occlusions they clear) 92.6% in a 51-study meta-analysis
Shelf #10792 · Heart, vessels, blood pressure & clotting
MEASUREMENT ACCURACY — PARTIAL
Stamped: 2026-11-28.
Evidence published: 2012–2025.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients with left bundle branch block and suspected acute coronary syndrome, how accurately do ECG criteria — the original Sgarbossa rule, the Smith-modified Sgarbossa criteria (proportional excessive discordance, ST/S ratio of −0.25 or lower), and the new-versus-old LBBB distinction — detect acute coronary occlusion or ST-elevation myocardial infarction?
Balance of the evidence
MEASUREMENT ACCURACY — PARTIAL — Composition: one derivation study (33 occlusion ECGs and 129 control ECGs) and one 51-study systematic review and meta-analysis (its total patient count is not stated in the abstract; the pools are not summed). Sensitivity and specificity are labelled in words at first occurrence in the title above. The derivation found the Smith-modified rule — replacing the absolute 5 mm discordant ST-elevation criterion with a proportional ST/S ratio of −0.25 or lower — reached sensitivity 91% (95% CI 76%–98%) and specificity 90% (83%–95%), significantly more sensitive than the weighted original Sgarbossa rule (52%) at lower specificity (98%), with positive and negative likelihood ratios of 9.0 and 0.1. The 51-study pool is more sober: modified Sgarbossa sensitivity 83.6% (55.4%–95.5%) and specificity 92.6% (78.9%–97.7%) for angiographically confirmed occlusive infarction, likelihood ratios 11.34 and 0.18 — while telling new from old LBBB was diagnostically neutral (positive likelihood ratio 1.30 and negative likelihood ratio 0.90, both intervals crossing 1.0, the value that means the finding made no difference to the odds). MEASUREMENT ACCURACY — PARTIAL: the modified criteria are the accurate tool and the chronology shortcut is not, but the pooled sensitivity interval is wide (55%–96%) and the derivation rests on 33 occlusions, so a negative ECG read does not exclude occlusion.
MeSH: Bundle-Branch Block/complications,diagnosis,physiopathology · Case-Control Studies · Coronary Occlusion/complications,diagnosis,physiopathology · Decision Support Techniques · Electrocardiography · Emergency Service, Hospital · Humans · Myocardial Infarction/complications,diagnosis,physiopathology · Sensitivity and Specificity
Cards (3)
Card 1 — Derivation (Smith 2012): replacing the 5 mm rule with an ST/S ratio of −0.25 or lower lifted sensitivity from 52% to 91% at specificity 90%
Study: Primary diagnostic accuracy derivation study
Population: Admission ECGs from patients with an acutely occluded coronary artery and left bundle branch block at 3 institutions (33 ECGs) and control ECGs from emergency-department patients with chest pain or dyspnoea and left bundle branch block without coronary occlusion (129 ECGs), with R/S waves and ST segments measured to the nearest 0.5 mm against the PR segment and angiographic occlusion as the reference standard.
Summary: Derivation (Smith 2012): replacing the 5 mm rule with an ST/S ratio of −0.25 or lower lifted sensitivity from 52% to 91% at specificity 90%
Result: Excessive relative discordant ST elevation (ST/S ratio −0.25 or lower) was present in 79% of occlusion ECGs versus 9% of controls, against 30% versus 9% for the absolute 5 mm criterion. The revised (Smith-modified) unweighted rule's sensitivity (in words: the share of occlusions the rule catches) was 91% (95% CI 76%–98%), significantly greater than the weighted (52%, 34%–69%) and unweighted (67%, 48%–82%) original Sgarbossa rules; its specificity (in words: the share of non-occlusions the rule clears) was 90% (83%–95%), lower than the weighted rule's 98% and the same as the unweighted rule's 90%. Positive and negative likelihood ratios for the revised rule were 9.0 (8.0–10) and 0.1 (0.03–0.3), and the revised rule was significantly more accurate overall than both originals.
Watch out: A case-control derivation with only 33 occlusions and controls drawn from ED patients with LBBB — a design that tends to flatter accuracy; the cut point (−0.25) was selected on the same data at a target of at least 90% specificity.
Source: Smith SW et al.. Diagnosis of ST-elevation myocardial infarction in the presence of left bundle branch block with the ST-elevation to S-wave ratio in a modified Sgarbossa rule. Annals of emergency medicine. 2012. PMID: 22939607. Registry ID: not stated in the record. MeSH: Bundle-Branch Block/complications,diagnosis,physiopathology · Case-Control Studies · Coronary Occlusion/complications,diagnosis,physiopathology · Decision Support Techniques · Electrocardiography · Emergency Service, Hospital · Humans · Myocardial Infarction/complications,diagnosis,physiopathology · Sensitivity and Specificity
Card 2 — 51-study meta-analysis (Alencar 2025): modified Sgarbossa sensitivity 83.6% and specificity 92.6% for occlusive infarction; new-versus-old LBBB diagnostically neutral
Study: Systematic review and meta-analysis of diagnostic accuracy
Population: 51 studies of patients with acute coronary syndrome and left bundle branch block, comparing the diagnostic accuracy of LBBB timing (new or presumed new versus old) with ischaemic ECG criteria, particularly the modified Sgarbossa criteria, against acute myocardial infarction or angiographically confirmed occlusion; risk of bias assessed with the Newcastle-Ottawa Scale and QUADAS-2 (total patient count not stated in the abstract).
Summary: 51-study meta-analysis (Alencar 2025): modified Sgarbossa sensitivity 83.6% and specificity 92.6% for occlusive infarction; new-versus-old LBBB diagnostically neutral
Result: LBBB occurred in 3.3% of acute coronary syndrome presentations and was associated with higher in-hospital mortality. Differentiating new from old LBBB was diagnostically neutral: positive likelihood ratio 1.30 (95% CI 0.75–1.85), negative likelihood ratio 0.90 (0.79–1.02) and diagnostic odds ratio 1.44 (0.93–2.24), all intervals crossing 1.0, the value that means the finding made no difference to the odds. The modified Sgarbossa criteria showed sensitivity 83.6% (95% CI 55.4%–95.5%) and specificity 92.6% (78.9%–97.7%) for angiographically confirmed occlusive infarction, with positive likelihood ratio 11.34 (3.67–34.99) and negative likelihood ratio 0.18 (0.054–0.575).
Watch out: The pooled sensitivity interval is very wide (55.4%–95.5%), reflecting heterogeneous primary studies and reference standards (infarction by biomarkers in some, angiographic occlusion in others); the neutral chronology result, by contrast, is consistent and precisely estimated enough to retire the shortcut.
Source: Alencar JN et al.. Accuracy of Left Bundle Branch Block Chronology and Electrocardiography Criteria for Acute Myocardial Infarction Diagnosis: A Systematic Review and Meta-analysis. Arquivos brasileiros de cardiologia. 2025. PMID: 41191702. Registry ID: not stated in the record. MeSH: Humans · Bundle-Branch Block/diagnosis,physiopathology,complications · Electrocardiography/methods · Myocardial Infarction/diagnosis,physiopathology · Sensitivity and Specificity · Acute Coronary Syndrome/complications,diagnosis · Time Factors · Predictive Value of Tests
Card 3 — Synthesis: use the proportional criteria, drop the chronology rule — PARTIAL because the pooled sensitivity interval is wide
Study: Synthesis
Population: One 162-ECG derivation study and one 51-study meta-analysis (patient total unstated in its abstract).
Summary: Synthesis: use the proportional criteria, drop the chronology rule — PARTIAL because the pooled sensitivity interval is wide
Result: Both records agree the Smith-modified criteria are substantially more sensitive than the original Sgarbossa rule at specificity near 90–93%, and the meta-analysis shows 'new LBBB' carries essentially no diagnostic information (likelihood ratios 1.30 and 0.90). A positive modified-Sgarbossa read strongly raises the odds of occlusion (likelihood ratio about 9–11); a negative read lowers them (0.1–0.18) without excluding occlusion. MEASUREMENT ACCURACY — PARTIAL.
Watch out: PARTIAL rather than GOOD because the derivation is small and case-control, the pooled sensitivity confidence interval spans 55%–96%, and paced rhythms — where the criteria are also used in practice — are not evaluated in either carded record.
Source: Synthesis of the reports carded above; no additional source.