SourceMed · Shelf #10805 in the ask interface
Sterile single-use versus clean reused catheters for intermittent catheterisation: 31 trials in the Cochrane review and still no convincing difference in urinary infection
Shelf #10805 · Urology & men’s health
MAYBE (weak evidence)
Stamped: 2026-11-28.
Evidence published: 1993–2014.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In adults and children who empty the bladder by long-term intermittent catheterisation, do aseptic technique and single-use (sterile) catheters reduce urinary tract infection compared with clean technique and multiple-use (reused) catheters?
Balance of the evidence
MAYBE (weak evidence) — Composition: 1 Cochrane systematic review (31 trials: 13 randomised trials and 18 randomised cross-over trials) and 1 small randomised cross-over primary study (30 children); total documented evidence base above the 30 minimum, but most included trials completed fewer than 60 participants. Diagnosis first: this shelf asks about technique and reuse only — catheter coatings are shelved separately. The Cochrane review's conclusion is plain: despite 31 trials there is no convincing evidence that urinary infection incidence is affected by aseptic versus clean technique, or by single-use (sterile) versus multiple-use (clean) catheters; where data existed, confidence intervals were wide, so clinically important differences could neither be identified nor reliably ruled out. The one primary study carded here fits that picture: in 30 children with spina bifida crossing over between sterile single-use and clean reused catheters, 38% of all urine cultures were positive regardless of which catheter strategy was used, and a parallel group using only sterile catheters had a 36% positive-culture rate. That is an absence of demonstrated difference on weak, old, small trials — not proof the strategies are equal — so the stamp is MAYBE (weak evidence). MAYBE (weak evidence).
MeSH: Urinary Catheterization/adverse effects,instrumentation,methods · Urinary Tract Infections/etiology,prevention & control · Equipment Reuse · Urinary Retention/therapy · Bacteriuria/epidemiology,etiology · Spinal Dysraphism/urine · Humans
Cards (3)
Card 1 — Prieto 2014 (Cochrane): across 31 trials, no convincing evidence that aseptic technique or single-use catheters reduce urinary infection versus clean technique or reused catheters
Study: Cochrane systematic review of randomised and cross-over trials
Population: Adults and children using intermittent catheterisation for incomplete bladder emptying; 31 trials met inclusion (13 randomised trials, 18 randomised cross-over trials); most trials had fewer than 60 participants completing, five had more than 100; 15 trials were more than 10 years old at the review.
Summary: Prieto 2014 (Cochrane): across 31 trials, no convincing evidence that aseptic technique or single-use catheters reduce urinary infection versus clean technique or reused catheters
Result: It was not possible to combine data from some trials because the catheters and coatings tested varied. Where there were data, confidence intervals around estimates were wide and clinically important differences in urinary tract infection and other outcomes could neither be identified nor reliably ruled out. The authors conclude there is still no convincing evidence that infection incidence is affected by aseptic or clean technique, coated or uncoated catheters, single (sterile) or multiple-use (clean) catheters, or self-catheterisation versus catheterisation by others; no study assessed cost-effectiveness.
Watch out: Definitions of urinary infection varied between trials, dropout was a problem in longer trials, and the review's searches closed in September 2013 — the verdict is 'unproven either way' on a weak base, not equivalence.
Source: Prieto J et al. Intermittent catheterisation for long-term bladder management. Cochrane Database Syst Rev. 2014. PMID: 25208303. Registry ID: none in the record. MeSH: Adult · Child · Equipment Reuse · Female · Humans · Male · Patient Dropouts · Urinary Catheterization/adverse effects,instrumentation,methods · Urinary Catheters/adverse effects · Urinary Retention/therapy · Urinary Tract Infections/etiology,prevention & control
Card 2 — Moore 1993: in 30 children with spina bifida, 38% of urine cultures were positive on sterile single-use catheters — and 38% on clean reused catheters
Study: Randomised cross-over study (N = 30, printed plainly)
Population: 30 subjects with spina bifida, aged 3–16 years, on long-term intermittent self-catheterisation, randomly assigned in a cross-over design to 6 months of sterile single-use catheters or clean reused catheters; 17 were catheterised by a parent or caregiver and 13 catheterised themselves; a separate descriptive group at another hospital used sterile catheters only.
Summary: Moore 1993: in 30 children with spina bifida, 38% of urine cultures were positive on sterile single-use catheters — and 38% on clean reused catheters
Result: In the cross-over group, 38% of all monthly urine cultures were positive regardless of whether sterile single-use or clean reused catheters were employed; the sterile-only comparison group had a 36% positive culture rate. No difference in positive cultures was found between males and females or between self-catheterised and parent-catheterised children. The authors concluded that plastic urethral catheters may be reused.
Watch out: The outcome is bacteriuria on monthly cultures, not symptomatic urinary infection; N = 30 children with spina bifida in 1993, with catheter materials and cleaning practice of that era — it cannot settle the question for adults or modern catheters.
Source: Moore KN et al. Bacteriuria in intermittent catheterization users: the effect of sterile versus clean reused catheters. Rehabil Nurs. 1993. PMID: 8066320. Registry ID: none in the record. MeSH: Adolescent · Bacteriuria/epidemiology,etiology,urine · Catheters, Indwelling/adverse effects · Child · Disinfection/methods · Equipment Reuse · Female · Humans · Male · Spinal Dysraphism/urine · Sterilization · Urinary Catheterization/adverse effects,instrumentation
Card 3 — Synthesis: reuse and clean technique have never been shown worse — and never been proven equal — in trials large enough to tell
Study: Synthesis
Population: One Cochrane review (31 trials, mostly small) and one 30-child cross-over study of bacteriuria.
Summary: Synthesis: reuse and clean technique have never been shown worse — and never been proven equal — in trials large enough to tell
Result: Every layer of the record points the same way: no demonstrated infection advantage for sterile single-use catheters or aseptic technique, on evidence too weak and too old to exclude a clinically important difference. Practice therefore turns on cost, supply and patient preference rather than on a proven infection benefit — and the stamp reflects the weakness of the base, MAYBE (weak evidence).
Watch out: This shelf does not cover coated versus uncoated catheters (shelved separately in spinal cord injury) or indwelling catheter care; bacteriuria is not the same outcome as symptomatic infection.
Source: Synthesis of the cards above; no additional source.