SourceMed · Shelf #10815 in the ask interface

Low-level laser therapy for tendinopathy splits by tendon and dose: pooled elbow trials show about 10 mm extra pain relief, one Achilles trial found faster recovery and the other found none

Shelf #10815 · Bones & joints

SPLIT (by tendon and dose)

Stamped: 2026-11-28.

Evidence published: 2008–2022.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In adults with tendinopathy, does low-level laser therapy (photobiomodulation) reduce pain and improve function compared with placebo laser or exercise alone, and does the answer depend on the tendon treated and the dose delivered?

Balance of the evidence

SPLIT (by tendon and dose) — Composition: 2 meta-analyses (13 placebo-controlled elbow trials, 730 patients; and a lower-extremity review of 18 trials) and 2 randomised Achilles trials (52 and 40 patients). Total documented evidence base 822 patients counted once (the elbow pool plus the two Achilles trials; the lower-extremity review overlaps the Achilles trials and is not added). Diagnosis first: 'laser for tendon pain' is not one question — the dose reaching the tendon and the tendon's depth decide the biology, and the trials split exactly along those lines. For lateral elbow tendinopathy, the pooled placebo-controlled trials show a weighted mean pain advantage of 10.2 mm on a 100 mm scale and a relative risk of global improvement of 1.36 — but the effect concentrated in trials that irradiated the tendon insertion directly at 904 nm or 632 nm (pain advantage 17.2 mm and 14.0 mm), while trials using acupuncture points or 820/830/1064 nm were negative, and publication bias was detected (Bjordal 2008). For Achilles tendinopathy the two adjunct-to-eccentric-exercise trials contradict each other: pain during activity was far lower with laser at 4–12 weeks in one (53.6 versus 71.5 mm at 4 weeks; Stergioulas 2008) and no better — at 4 weeks significantly worse on the primary score — in the other (Tumilty 2012). The lower-extremity meta-analysis finds pain about 13–15 mm lower with recommended doses, at end of treatment and weeks later (Naterstad 2022). No serious harms are reported in these records. SPLIT (by tendon and dose): laser at recommended doses, applied directly to the tendon, probably buys a small pain reduction in elbow and lower-limb tendinopathy; at other wavelengths, doses or targets the trials are negative, and the Achilles adjunct evidence is one trial each way.

MeSH: Achilles Tendon · Adult · Athletic Injuries · Chronic Disease · Combined Modality Therapy · Elbow Joint · Exercise Therapy · Fasciitis, Plantar · Female · Humans · Laser Therapy · Low-Level Light Therapy · Lower Extremity · Male · Middle Aged · Pain · Pain Measurement · Physical Therapy Modalities · Randomized Controlled Trials as Topic · Single-Blind Method · Tendinopathy · Tennis Elbow · Treatment Outcome

Cards (5)

Card 1 — Meta-analysis, 13 placebo-controlled trials (730 patients): laser relieved tennis elbow pain by 10.2 mm more than placebo — but only the trials irradiating the tendon directly at 904 or 632 nm were clearly positive (Bjordal 2008)

Study: Systematic review and meta-analysis, 13 trials, N = 730

Population: Systematic review of randomised placebo-controlled trials in lateral elbow tendinopathy: 18 trials identified, 13 (730 patients) meeting criteria for meta-analysis; 12 satisfied at least half the methodological criteria, and 10 included poor-prognosis patients (failed steroid injections, long duration or severe pain).

Summary: Meta-analysis, 13 placebo-controlled trials (730 patients): laser relieved tennis elbow pain by 10.2 mm more than placebo — but only the trials irradiating the tendon directly at 904 or 632 nm were clearly positive (Bjordal 2008)

Result: The weighted mean difference for pain relief was 10.2 mm (95% CI 3.0 to 17.5) and the relative risk for global improvement was 1.36 (1.16 to 1.60). Trials targeting acupuncture points were negative, as were trials at 820, 830 and 1064 nm. In the subgroup irradiating the lateral elbow tendon insertions directly — five trials at 904 nm and one at 632 nm, doses 0.5 to 7.2 Joules — pain relief was 17.2 mm (8.5 to 25.9) and 14.0 mm (7.4 to 20.6) respectively, and pain-free grip strength, pain pressure threshold and sick leave also favoured laser at 3–8 weeks. Egger's test detected publication bias.

Watch out: The headline pool mixes doses the authors themselves judge sub-therapeutic with adequate ones; the positive subgroup is a post-hoc dose-and-target selection, and detected publication bias means the true average effect is probably smaller than 10.2 mm.

Source: Bjordal JM, Lopes-Martins RA, Joensen J, et al. A systematic review with procedural assessments and meta-analysis of low level laser therapy in lateral elbow tendinopathy (tennis elbow). BMC musculoskeletal disorders 2008. PMID: 18510742. Registry ID: not stated in the record. MeSH: Elbow Joint · Humans · Low-Level Light Therapy · Randomized Controlled Trials as Topic · Tendinopathy · Tennis Elbow · Therapeutics

Card 2 — Randomised trial, 52 athletes: adding laser to eccentric exercise cut Achilles pain during activity to 53.6 mm versus 71.5 mm on placebo laser at 4 weeks, with the gap persisting to 12 weeks (Stergioulas 2008)

Study: Primary randomised controlled trial, N = 52

Population: 52 recreational athletes with chronic Achilles tendinopathy, randomised to eccentric exercise plus active low-level laser (820 nm, 12 sessions over 8 weeks, 5.4 J per session over 6 points along the tendon) or eccentric exercise plus placebo laser, in a blinded design.

Summary: Randomised trial, 52 athletes: adding laser to eccentric exercise cut Achilles pain during activity to 53.6 mm versus 71.5 mm on placebo laser at 4 weeks, with the gap persisting to 12 weeks (Stergioulas 2008)

Result: Pain intensity during physical activity (100 mm visual analogue scale) was significantly lower with laser: 53.6 versus 71.5 mm at 4 weeks (P = .0003), 37.3 versus 62.8 mm at 8 weeks (P = .0002) and 33.0 versus 53.0 mm at 12 weeks (P = .007). Morning stiffness, active dorsiflexion, palpation tenderness and crepitation showed the same pattern. The laser group's 4-week results resembled the placebo group's 12-week results.

Watch out: One small single-centre trial from a group that also authored the positive elbow meta-analysis; the 820 nm wavelength used here is one the elbow review found ineffective at the elbow — dose per point and tendon depth differ, but the inconsistency underlines how parameter-sensitive this literature is.

Source: Stergioulas A, Stergioula M, Aarskog R, Lopes-Martins RA, Bjordal JM. Effects of low-level laser therapy and eccentric exercises in the treatment of recreational athletes with chronic achilles tendinopathy. The American journal of sports medicine 2008. PMID: 18272794. Registry ID: not stated in the record. MeSH: Achilles Tendon · Adult · Athletic Injuries · Chronic Disease · Female · Humans · Laser Therapy · Male · Physical Therapy Modalities · Recreation · Single-Blind Method · Tendon Injuries · Treatment Outcome

Card 3 — Randomised trial, 40 patients: adding laser to eccentric exercise made no difference to Achilles function scores at any point to 52 weeks — at 4 weeks the placebo group scored significantly better (Tumilty 2012)

Study: Primary randomised controlled trial, N = 40

Population: 40 adults with midportion Achilles tendinopathy in a primary care clinic, randomised to eccentric exercise plus active low-level laser (3 J per point, 3 times weekly for 4 weeks) or the same exercise plus placebo laser; 36 (90%) completed the 12-week evaluation and 33 (82.5%) the 52-week evaluation; observers were blinded.

Summary: Randomised trial, 40 patients: adding laser to eccentric exercise made no difference to Achilles function scores at any point to 52 weeks — at 4 weeks the placebo group scored significantly better (Tumilty 2012)

Result: The primary outcome, VISA-A score at 12 weeks, did not differ significantly between groups (P > .05), and neither did visual analogue pain scores at any time point. At 4 weeks the VISA-A difference significantly favoured the placebo group (P = .016) (the treatment made no difference overall, and the early difference ran against laser).

Watch out: A null result in 40 patients does not exclude a small effect, and the dose (3 J per point) was lower than in the positive trial's protocol; but as the only other blinded Achilles trial, it prevents the positive trial from standing unchallenged.

Source: Tumilty S, McDonough S, Hurley DA, Baxter GD. Clinical effectiveness of low-level laser therapy as an adjunct to eccentric exercise for the treatment of Achilles' tendinopathy: a randomized controlled trial. Archives of physical medicine and rehabilitation 2012. PMID: 22541305. Registry ID: not stated in the record. MeSH: Achilles Tendon · Adult · Combined Modality Therapy · Exercise Therapy · Female · Humans · Low-Level Light Therapy · Male · Middle Aged · Pain Measurement · Single-Blind Method · Surveys and Questionnaires · Tendinopathy

Card 4 — Meta-analysis, 18 randomised trials: laser reduced lower-extremity tendinopathy and plantar fasciitis pain by about 13 mm at end of treatment and 12.6 mm at 4–12 weeks, with recommended doses performing best (Naterstad 2022)

Study: Systematic review and meta-analysis, 18 trials (participant total not stated in the record)

Population: Systematic review and meta-analysis of randomised trials of low-level laser therapy in lower extremity tendinopathy or plantar fasciitis: comparisons against placebo (10 trials), other interventions (5) and as an add-on (3); study quality moderate to high by PEDro scale; dose subgroups followed World Association for Laser Therapy recommendations.

Summary: Meta-analysis, 18 randomised trials: laser reduced lower-extremity tendinopathy and plantar fasciitis pain by about 13 mm at end of treatment and 12.6 mm at 4–12 weeks, with recommended doses performing best (Naterstad 2022)

Result: Pain was significantly reduced by laser at completed therapy (13.15 mm on the visual analogue scale, 95% CI 7.82 to 18.48) and 4–12 weeks later (12.56 mm, 5.69 to 19.42); disability was also reduced (standardised mean difference 0.39 at end of therapy, 0.32 at 4–9 weeks). At recommended doses versus placebo, pain fell by 14.98 mm at end of therapy and 14.00 mm at 4–8 weeks; as an add-on to exercise, by 18.15 mm at end of therapy. No adverse events were reported in the abstracted results.

Watch out: This pool includes the two Achilles trials carded above, which disagree with each other, and mixes tendinopathy with plantar fasciitis; the pooled average hides the dose dependence the authors' own subgroup analysis demonstrates.

Source: Naterstad IF, Joensen J, Bjordal JM, Couppé C, Lopes-Martins RA, et al. Efficacy of low-level laser therapy in patients with lower extremity tendinopathy or plantar fasciitis: systematic review and meta-analysis of randomised controlled trials. BMJ open 2022. PMID: 36171024. Registry ID: not stated in the record. MeSH: Fasciitis, Plantar · Humans · Low-Level Light Therapy · Lower Extremity · Pain · Randomized Controlled Trials as Topic · Tendinopathy

Card 5 — Synthesis: laser for tendon pain is a dose-and-target story — direct irradiation at recommended doses gives a small, real-looking pain reduction; the wrong wavelength or target gives nothing, and the Achilles adjunct trials cancel out

Study: Synthesis

Population: Synthesis of 2 meta-analyses (13 elbow trials, 730 patients; 18 lower-extremity trials) and 2 randomised Achilles trials (52 and 40 patients).

Summary: Synthesis: laser for tendon pain is a dose-and-target story — direct irradiation at recommended doses gives a small, real-looking pain reduction; the wrong wavelength or target gives nothing, and the Achilles adjunct trials cancel out

Result: Elbow: +10.2 mm pain relief overall, +17.2 mm in the directly-irradiated 904 nm subgroup, null at 820/830/1064 nm and at acupuncture points (Bjordal). Achilles adjunct: strongly positive (Stergioulas) versus null (Tumilty). Lower extremity overall: −13.15 mm pain at end of treatment, −14.98 mm at recommended doses versus placebo (Naterstad).

Watch out: Laser for neck pain is a separate, already-shelved question (live shelf #4208), and laser parameters are not interchangeable between devices: a clinic cannot reproduce these results without matching wavelength, dose and application points.

Source: Synthesis of PMID: 18510742, PMID: 18272794, PMID: 22541305, PMID: 36171024.