SourceMed · Shelf #10839 in the ask interface

Tests for acute sinusitis are modest against the puncture reference: radiography's summary point where sensitivity (in words: the share of true sinusitis cases detected) equals specificity (in words: the share of non-cases cleared) is 0.82, clinical examination's is 0.75

Shelf #10839 · Eyes, skin, nose & allergy

MEASUREMENT ACCURACY — PARTIAL

Stamped: 2026-11-28.

Evidence published: 2000–2016.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with suspected acute rhinosinusitis, how accurately do clinical examination, plain radiography, ultrasound and inflammatory markers (C-reactive protein, erythrocyte sedimentation rate) detect sinus infection against antral puncture or imaging reference standards?

Balance of the evidence

MEASUREMENT ACCURACY — PARTIAL — Composition: two systematic reviews (11 primary studies with 1,144 patients in the 2000 review; the 2016 review's study count is not stated in its abstract), counted as syntheses. Against antral puncture — the strictest reference — every test is modest: radiography's summary ROC Q* point (the point where sensitivity and specificity, labelled in words in the title, are equal) was 0.82, ultrasound's 0.80 and clinical examination's 0.75. Accuracy figures inflate sharply when imaging is used as its own reference standard (likelihood ratios up to 12.4), which the 2016 review itself flags as likely overestimation. Erythrocyte sedimentation rate above 40 had a positive likelihood ratio of 7.40, the strongest single laboratory finding. MEASUREMENT ACCURACY — PARTIAL: a negative radiograph helps exclude, a high ESR helps confirm, and no carded test does both.

MeSH: Acute Disease · Blood Sedimentation · C-Reactive Protein/metabolism · Humans · Prevalence · Primary Health Care · Radiography · Reproducibility of Results · Rhinitis/blood,diagnosis,epidemiology · Sensitivity and Specificity · United States/epidemiology

Cards (3)

Card 1 — Primary-care test-accuracy review (Ebell 2016): against antral puncture, radiography positive likelihood ratio 2.01 and negative 0.28; ultrasound 1.64–1.71 positive; ESR above 40 reached 7.40

Study: Systematic review of diagnostic test accuracy

Population: Studies of patients presenting with or referred for suspected acute rhinosinusitis in outpatient, primary care and specialty settings, analysed by bivariate meta-analysis, with accuracy reported separately against antral puncture and against imaging reference standards.

Summary: Primary-care test-accuracy review (Ebell 2016): against antral puncture, radiography positive likelihood ratio 2.01 and negative 0.28; ultrasound 1.64–1.71 positive; ESR above 40 reached 7.40

Result: Using antral puncture as the reference standard, A-mode ultrasound (positive likelihood ratio 1.71, negative likelihood ratio 0.41), B-mode ultrasound (1.64 and 0.69) and radiography (2.01 and 0.28) had only modest accuracy. Using imaging as the reference standard, accuracy appeared higher for ultrasound (positive likelihood ratio 12.4, negative 0.35) and radiography (9.4 and 0.27), which the authors note likely overestimates accuracy. C-reactive protein and erythrocyte sedimentation rate showed threshold effects with modest overall accuracy; the positive likelihood ratio for ESR was 4.08 above 30 and 7.40 above 40. A nasal-secretion leucocyte-esterase dipstick was highly accurate (18.4 and 0.17) but has not been validated.

Watch out: The flattering likelihood ratios come from studies that used imaging as the reference standard for an imaging test — a circular comparison; the puncture-referenced numbers are the honest ones, and the dipstick result is a single unvalidated finding.

Source: Ebell MH et al.. Diagnosis of acute rhinosinusitis in primary care: a systematic review of test accuracy. The British journal of general practice : the journal of the Royal College of General Practitioners. 2016. PMID: 27481857. Registry ID: not stated in the record. MeSH: Acute Disease · Blood Sedimentation · C-Reactive Protein/metabolism · Humans · Prevalence · Primary Health Care · Radiography · Reproducibility of Results · Rhinitis/blood,diagnosis,epidemiology · Sensitivity and Specificity · United States/epidemiology

Card 2 — Earlier systematic review (Varonen 2000): against sinus puncture, summary Q* was 0.82 for radiography, 0.80 for ultrasound and 0.75 for clinical examination (11 studies, 1,144 patients)

Study: Systematic review of diagnostic accuracy studies

Population: 11 eligible evaluation studies (from 49 reports, 1962 onward) totalling 1,144 adults with suspected acute maxillary sinusitis, comparing clinical examination, radiography and ultrasound against a reference standard, summarised with summary ROC curves and Q* points (the point where sensitivity and specificity are equal).

Summary: Earlier systematic review (Varonen 2000): against sinus puncture, summary Q* was 0.82 for radiography, 0.80 for ultrasound and 0.75 for clinical examination (11 studies, 1,144 patients)

Result: Compared with sinus puncture, radiography was the most accurate method, with a Q* point of 0.82 (95% CI 0.78–0.85). Ultrasound was slightly less accurate (Q* 0.80, 0.76–0.83). Only two articles reported clinical examination against sinus puncture, with a Q* of 0.75 (0.58–0.86). The authors conclude clinical examination is a rather unreliable method for diagnosing acute maxillary sinusitis even in experienced specialists' hands, and that the diagnosis is rarely studied in primary care settings.

Watch out: The clinical-examination estimate rests on only two studies with a wide interval (0.58–0.86), and the primary literature spans from 1962 — older radiography and ultrasound technology than current practice.

Source: Varonen H et al.. Comparison of ultrasound, radiography, and clinical examination in the diagnosis of acute maxillary sinusitis: a systematic review. Journal of clinical epidemiology. 2000. PMID: 11004420. Registry ID: not stated in the record. MeSH: Acute Disease · Adult · Humans · Maxillary Sinusitis/diagnosis,diagnostic imaging · Punctures · ROC Curve · Sensitivity and Specificity · Tomography, X-Ray Computed · Ultrasonography

Card 3 — Synthesis: modest tests, an honest reference standard, and one useful laboratory threshold — PARTIAL

Study: Synthesis

Population: Two systematic reviews of the test-accuracy literature for suspected acute rhinosinusitis (11 studies, 1,144 patients in the earlier review).

Summary: Synthesis: modest tests, an honest reference standard, and one useful laboratory threshold — PARTIAL

Result: Against antral puncture, radiography (Q* 0.82; negative likelihood ratio 0.28) is the best of a modest set, ultrasound is close behind (Q* 0.80), clinical examination is weakest (Q* 0.75), and an ESR above 40 gives the strongest rule-in signal (positive likelihood ratio 7.40). MEASUREMENT ACCURACY — PARTIAL.

Watch out: PARTIAL because accuracy is reference-standard-dependent — the same tests look far better when imaging judges imaging — and because the primary-care evidence the 2016 review sought remains thin.

Source: Synthesis of the reports carded above; no additional source.