SourceMed · Shelf #10843 in the ask interface

Telmisartan did not slow small abdominal aortic aneurysm growth in TEDY: 1.68 versus 1.78 mm per year on ultrasound (the treatment made no difference)

Shelf #10843 · Heart, vessels, blood pressure & clotting

POSSIBLE

Stamped: 2026-11-28.

Evidence published: 2020.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In patients with small (35–49 mm) abdominal aortic aneurysms, does telmisartan 40 mg daily, compared with placebo, slow aneurysm growth?

Balance of the evidence

POSSIBLE — Composition: one randomised, double-blind, placebo-controlled trial (TEDY; 210 patients with 35–49 mm aneurysms). Telmisartan lowered blood pressure (systolic 8.9 mm Hg lower at 1 year) but did not slow aneurysm growth on ultrasound (1.68 versus 1.78 mm per year; mean difference −0.11 mm per year, 95% CI −0.60 to 0.38; P =.66), on CT diameter or volume, or reduce aneurysm-related events, and hypotensive symptoms were twice as common. A single trial, so the stamp stays at POSSIBLE even though the result is null. POSSIBLE: telmisartan does not slow small-aneurysm growth (the treatment made no difference).

MeSH: Aged · Aged, 80 and over · Angiotensin II Type 1 Receptor Blockers/therapeutic use · Aortic Aneurysm, Abdominal/drug therapy,pathology · Disease Progression · Double-Blind Method · Female · Humans · Male · Telmisartan/therapeutic use · Treatment Outcome

Cards (2)

Card 1 — TEDY (Golledge 2020): aneurysm growth 1.68 mm/y on telmisartan versus 1.78 mm/y on placebo — no difference, despite lower blood pressure

Study: Randomised controlled trial

Population: 210 patients with 35- to 49-mm abdominal aortic aneurysms recruited in Australia, the Netherlands and the US, randomised to telmisartan 40 mg daily (107) or placebo (103); 88% men, mean age 73.5 years; 188 (91%) had at least two ultrasound scans.

Summary: TEDY (Golledge 2020): aneurysm growth 1.68 mm/y on telmisartan versus 1.78 mm/y on placebo — no difference, despite lower blood pressure

Result: Ultrasound-measured growth was 1.68 mm per year on telmisartan versus 1.78 mm per year on placebo (mean difference −0.11 mm per year; 95% CI, −0.60 to 0.38; P = .66) — the treatment made no difference. CT-measured diameter and volume, aneurysm-related events (relative risk 1.35; 95% CI, 0.54–3.35) and quality of life likewise did not differ, although systolic pressure was 8.9 mm Hg lower on telmisartan at 1 year and hypotensive symptoms were twice as common.

Watch out: The trial enrolled 210 of 300 intended participants, so a small growth effect cannot be excluded; the confidence interval (−0.60 to 0.38 mm per year) still allows a modest slowing.

Source: Golledge J et al.. Efficacy of Telmisartan to Slow Growth of Small Abdominal Aortic Aneurysms: A Randomized Clinical Trial. JAMA cardiology. 2020. PMID: 32845283. Registry ID: ClinicalTrials.gov NCT01683084; ANZCTR ACTRN12611000931976. MeSH: Aged · Aged, 80 and over · Angiotensin II Type 1 Receptor Blockers/therapeutic use · Aortic Aneurysm, Abdominal/drug therapy,pathology · Disease Progression · Double-Blind Method · Female · Humans · Male · Telmisartan/therapeutic use · Treatment Outcome

Card 2 — Synthesis: one adequately blinded trial, a clear null on every growth measure — POSSIBLE

Study: Synthesis

Population: One trial, 210 randomised patients with small abdominal aortic aneurysms.

Summary: Synthesis: one adequately blinded trial, a clear null on every growth measure — POSSIBLE

Result: Growth by ultrasound, CT diameter, CT volume and clinical aneurysm events all agree: telmisartan made no difference. POSSIBLE.

Watch out: POSSIBLE rather than higher because a single trial carries the question, and recruitment fell short of target.

Source: Synthesis of the report carded above; no additional source.