SourceMed · Shelf #10883 in the ask interface
Total hepatic blood flow in healthy fasting adults is about 17–20 mL/min/kg — roughly 1.2–1.4 L/min — with the portal vein supplying about four-fifths and the hepatic artery the rest, and the artery dilating or constricting to buffer changes in portal flow
Shelf #10883 · Liver & gut
PHYSIOLOGY — EMERGING
Stamped: 2026-11-28.
Evidence published: 1992–2010.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In healthy humans, how much blood flows through the liver each minute — what are total hepatic blood flow and its portal-vein and hepatic-artery components measured non-invasively — and how does the hepatic arterial buffer response stabilise total flow when portal flow changes?
Balance of the evidence
PHYSIOLOGY — EMERGING — Small evidence base, stated on the face: only 30 healthy adults have directly measured total hepatic blood flow in the two primary studies (10 by duplex ultrasound, 20 by phase-contrast MRI), supported by one physiology review of the buffer response; the total documented evidence base is under 30 measured volunteers plus the review, so this stamp is EMERGING, not ESTABLISHED. The two measurements agree: total flow 17.0 mL/min/kg by duplex and 19.7 mL/min/kg (1.35 L/min) by MRI, with the hepatic artery contributing about one-fifth. The buffer response — arterial dilation when portal flow falls, mediated by adenosine washout — is the accepted intrinsic regulator that holds total flow roughly constant. PHYSIOLOGY — EMERGING.
MeSH: Adult · Female · Hepatic Artery/anatomy & histology,physiology · Hepatic Veins/anatomy & histology,physiology · Humans · Liver Circulation/physiology · Magnetic Resonance Angiography/methods · Male · Perfusion Imaging/methods · Reproducibility of Results · Sensitivity and Specificity
Cards (3)
Card 1 — Carlisle 1992: in 10 fasting healthy volunteers, duplex ultrasound gave portal vein flow 13.5 mL/min/kg, hepatic artery flow 3.5 mL/min/kg and total hepatic flow 17.0 mL/min/kg
Study: Primary physiological study
Population: 10 normal healthy volunteers studied fasting, in whom volume flow was measured with a duplex ultrasound system in the portal vein and at two hepatic-artery sites (common hepatic artery just after the coeliac bifurcation, and the hepatic artery proper just proximal to the porta hepatis); total hepatic blood flow was taken as portal plus hepatic-artery flow.
Summary: Carlisle 1992: in 10 fasting healthy volunteers, duplex ultrasound gave portal vein flow 13.5 mL/min/kg, hepatic artery flow 3.5 mL/min/kg and total hepatic flow 17.0 mL/min/kg
Result: Mean (SD) volume flow was 13.5 (21%) mL/min/kg in the portal vein, 3.5 (45%) mL/min/kg in the hepatic artery proper and 6.9 (30%) mL/min/kg in the common hepatic artery; total hepatic flow was 17.0 (16%) mL/min/kg. The artery measurement site mattered: the common hepatic artery value was about double the hepatic-artery-proper value, because the common trunk also carries branches beyond the liver.
Watch out: Only 10 volunteers, and the percentage SDs are wide (45% for hepatic artery flow); the common-hepatic-artery figure must not be used as the liver's arterial inflow, since that trunk supplies other organs too.
Source: Carlisle KM et al.. Estimation of total hepatic blood flow by duplex ultrasound. Gut. 1992. PMID: 1740284. Registry ID: not stated in the record. MeSH: Blood Flow Velocity/physiology · Hepatic Artery/diagnostic imaging,physiology · Humans · Portal Vein/diagnostic imaging,physiology · Reference Values · Regional Blood Flow · Ultrasonography
Card 2 — Yzet 2010: phase-contrast MRI in 20 healthy adults measured total hepatic flow at 1.35 L/min (19.7 mL/min/kg), with the proper hepatic artery providing 19.1% of inflow
Study: Primary physiological study
Population: 20 healthy subjects (mean age 26 years) studied with 1.5T gradient-echo 2D fast cine phase-contrast MRI with cardiac and respiratory gating, measuring flow in the portal vein and the proper hepatic artery, including how vessel cross-section changed across the cardiac cycle.
Summary: Yzet 2010: phase-contrast MRI in 20 healthy adults measured total hepatic flow at 1.35 L/min (19.7 mL/min/kg), with the proper hepatic artery providing 19.1% of inflow
Result: Total hepatic flow rate was 1.35 ± 0.18 L/min, or 19.7 ± 4.6 mL/min/kg; the proper hepatic artery provided 19.1% of the total hepatic blood flow entering the liver, so the portal vein provided about four-fifths. Portal vein area varied over the cardiac cycle with a mean 'pulsatility' index of 18%. The authors note their values agree with earlier direct measurements, while their velocity values differed from published Doppler data.
Watch out: Young adults only (mean age 26), so the values are a young-adult reference; velocity and volume flow are not interchangeable, and the paper itself flags disagreement between MRI and Doppler velocity values.
Source: Yzet T et al.. Dynamic measurements of total hepatic blood flow with Phase Contrast MRI. European journal of radiology. 2010. PMID: 19008062. Registry ID: not stated in the record. MeSH: Adult · Female · Hepatic Artery/anatomy & histology,physiology · Hepatic Veins/anatomy & histology,physiology · Humans · Liver Circulation/physiology · Magnetic Resonance Angiography/methods · Male · Perfusion Imaging/methods · Reproducibility of Results · Sensitivity and Specificity
Card 3 — Lautt 1996 (review): the hepatic arterial buffer response is the liver's intrinsic flow regulator — doubling portal flow maximally constricts the artery, and low portal flow maximally dilates it, via adenosine washout
Study: Physiology review
Population: A physiology review (the 1995 Ciba-Geigy Award Lecture) synthesising the experimental evidence on intrinsic regulation of hepatic blood flow, in which extrinsic factors (sympathetic nerves, blood-borne agents) are controlled so the intrinsic arterial response can be isolated.
Summary: Lautt 1996 (review): the hepatic arterial buffer response is the liver's intrinsic flow regulator — doubling portal flow maximally constricts the artery, and low portal flow maximally dilates it, via adenosine washout
Result: Intrinsic regulation acts only through the hepatic artery, because the liver cannot directly regulate portal vein flow. In the buffer response, adenosine is produced at a constant rate into a small fluid compartment around the hepatic arterial resistance vessels: when portal flow falls, less adenosine is washed away, it accumulates, and the artery dilates; when portal flow rises, washout increases and the artery constricts. Doubling portal vein flow leads to maximal arterial constriction and low portal flow to maximal dilation. Hepatic arterial autoregulation works by the same washout mechanism, and together these mechanisms tend to hold total hepatic blood flow constant, stabilising hepatic clearance, venous return and cardiac output.
Watch out: A mechanistic review resting largely on animal and experimental preparations; it establishes the direction and mechanism of the buffer response, not a numeric human reference range.
Source: Lautt WW. The 1995 Ciba-Geigy Award Lecture. Intrinsic regulation of hepatic blood flow. Canadian journal of physiology and pharmacology. 1996. PMID: 8773400. Registry ID: not stated in the record. MeSH: Buffers · Hepatic Artery/physiology · Homeostasis/physiology · Humans · Liver/blood supply,metabolism · Liver Circulation/physiology · Portal Pressure/physiology