SourceMed · Shelf #10888 in the ask interface
Contrast-enhanced ultrasound separates malignant from benign focal liver lesions well: pooled sensitivity (in words: the share of malignant lesions it calls malignant) 0.92 and specificity (in words: the share of benign lesions it calls benign) 0.87 across 57 studies
Shelf #10888 · Liver & gut
MEASUREMENT ACCURACY — GOOD
Stamped: 2026-11-28.
Evidence published: 2018.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients with a focal liver lesion, how accurately does contrast-enhanced ultrasound (CEUS) distinguish malignant from benign lesions against reference standards — what are its pooled sensitivity and specificity (each labelled in words), and how much do the contrast agent generation and agent type change accuracy?
Balance of the evidence
MEASUREMENT ACCURACY — GOOD — One comprehensive meta-analysis of 57 studies: pooled sensitivity (in words: the share of malignant lesions correctly called malignant) 0.92 and specificity (in words: the share of benign lesions correctly called benign) 0.87, diagnostic odds ratio 104. Second-generation agents outperformed the first-generation agent (diagnostic odds ratio 118 versus 63), and Sonazoid scored highest of the three named agents. The total number of participants across the 57 studies is not stated in the abstract, so no pooled N is printed. Accuracy is for characterising a lesion already found, not for finding lesions or for staging. MEASUREMENT ACCURACY — GOOD.
MeSH: Contrast Media/pharmacology · Diagnosis, Differential · Humans · Liver/diagnostic imaging · Liver Diseases/diagnosis · Ultrasonography/methods
Cards (2)
Card 1 — Wu 2018 meta-analysis (57 studies): CEUS pooled sensitivity 0.92 and specificity 0.87 for malignant versus benign focal liver lesions, diagnostic odds ratio 104
Study: Systematic review and meta-analysis of diagnostic accuracy studies
Population: 57 studies of contrast-enhanced ultrasound used to characterise focal liver lesions, identified from the Cochrane Library, PubMed and Web of Science, with data extracted to build 2×2 tables against reference standards and study quality assessed with the QUADAS tool; the total participant count is not stated in the abstract.
Summary: Wu 2018 meta-analysis (57 studies): CEUS pooled sensitivity 0.92 and specificity 0.87 for malignant versus benign focal liver lesions, diagnostic odds ratio 104
Result: Pooled sensitivity (in words: the share of malignant lesions correctly identified as malignant) was 0.92 (95% CI 0.91–0.93) and pooled specificity (in words: the share of benign lesions correctly identified as benign) was 0.87 (95% CI 0.86–0.88); the diagnostic odds ratio was 104.20 (95% CI 70.42–154.16). No potential publication bias was observed among the included studies.
Watch out: Characterisation accuracy in referred patients with known lesions; it does not measure how well CEUS detects lesions in the first place, and accuracy against mixed reference standards in mostly retrospective series can run optimistic.
Source: Wu M et al.. Contrast-enhanced US for characterization of focal liver lesions: a comprehensive meta-analysis. European radiology. 2018. PMID: 29189932. Registry ID: not stated in the record. MeSH: Contrast Media/pharmacology · Diagnosis, Differential · Humans · Liver/diagnostic imaging · Liver Diseases/diagnosis · Ultrasonography/methods
Card 2 — Wu 2018 (agent subgroups): second-generation contrast agents beat the first-generation agent (diagnostic odds ratio 118 versus 63), and Sonazoid scored highest (227) ahead of SonoVue (119) and Levovist (63)
Study: Subgroup analysis within a diagnostic accuracy meta-analysis
Population: The same 57-study meta-analysis, split by contrast agent generation and by the three major agents (SonoVue, Levovist, Sonazoid) in subgroup analyses and meta-regression.
Summary: Wu 2018 (agent subgroups): second-generation contrast agents beat the first-generation agent (diagnostic odds ratio 118 versus 63), and Sonazoid scored highest (227) ahead of SonoVue (119) and Levovist (63)
Result: Second-generation agents had a higher diagnostic odds ratio than the first-generation agent Levovist (118.27 versus 62.78). By agent, diagnostic odds ratios were: Sonazoid 227.39, SonoVue 118.82 and Levovist 62.78 — the authors conclude second-generation agents, especially Sonazoid, may greatly improve diagnostic performance.
Watch out: Between-study subgroup comparisons, not head-to-head trials of agents in the same patients; agent availability differs by country, and Sonazoid's estimate comes from the subset of (mainly Japanese) studies using it.
Source: Wu M et al.. Contrast-enhanced US for characterization of focal liver lesions: a comprehensive meta-analysis. European radiology. 2018. PMID: 29189932. Registry ID: not stated in the record. MeSH: Contrast Media/pharmacology · Diagnosis, Differential · Humans · Liver/diagnostic imaging · Liver Diseases/diagnosis · Ultrasonography/methods