SourceMed · Shelf #10889 in the ask interface

Salivary gland ultrasound for Sjögren's syndrome is scoring-system-dependent: pooled sensitivity (in words: the share of true cases it flags) ranges 75–84% and specificity (in words: the share of non-cases it clears) 88–95% depending on which scoring system is used

Shelf #10889 · Eyes, skin, nose & allergy

MEASUREMENT ACCURACY — PARTIAL

Stamped: 2026-11-28.

Evidence published: 2013–2018.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In people being assessed for Sjögren's syndrome, how accurately does salivary gland ultrasonography diagnose the syndrome against classification-criteria or expert reference standards — what sensitivity and specificity (each labelled in words) do the different ultrasound scoring systems achieve, and how does ultrasound compare with sialography?

Balance of the evidence

MEASUREMENT ACCURACY — PARTIAL — Two meta-analyses and one prospective cohort agree that salivary gland ultrasound is specific but only moderately sensitive, and that the answer depends on the scoring system: pooled sensitivity (in words: the share of true Sjögren's cases the scan flags) 75–84% and specificity (in words: the share of non-cases it correctly clears) 88–95% across systems, with high between-study heterogeneity (I² up to 92%). In the best single prospective cohort, the optimal gland-grade cut-off gave sensitivity 62.8% and specificity 95.0%. Ultrasound performs comparably to sialography. MEASUREMENT ACCURACY — PARTIAL.

MeSH: Consensus · Databases, Factual · Humans · Odds Ratio · Salivary Glands/pathology · Sensitivity and Specificity · Severity of Illness Index · Sjogren's Syndrome/diagnosis,pathology · Ultrasonography/methods

Cards (3)

Card 1 — Zhou 2018 meta-analysis: across scoring systems, salivary ultrasound pooled sensitivity was 75–84% and specificity 88–95%, with areas under the summary ROC curve of 0.93–0.95 and heavy heterogeneity

Study: Systematic review and meta-analysis of diagnostic accuracy studies

Population: Systematic review and meta-analysis of salivary gland ultrasonography in primary Sjögren's syndrome, using the American-European Consensus Group criteria as reference: 1,301 articles retrieved, 24 studies meeting quality-assessment criteria and 14 entering the meta-analyses, split by the three scoring systems (scored 0–4, 0–16 and 0–48).

Summary: Zhou 2018 meta-analysis: across scoring systems, salivary ultrasound pooled sensitivity was 75–84% and specificity 88–95%, with areas under the summary ROC curve of 0.93–0.95 and heavy heterogeneity

Result: Pooled sensitivities (in words: shares of true cases flagged) were 75% (0–4 system, I² = 92.0%), 84% (0–16, I² = 63.6%) and 75% (0–48, I² = 90.9%); pooled specificities (in words: shares of non-cases cleared) were 93% (0–4, I² = 71.5%), 88% (0–16, I² = 65.4%) and 95% (0–48, I² = 83.9%). Areas under the summary ROC curves were 0.95, 0.93 and 0.94 respectively. The authors conclude the 0–4 system has higher specificity and less heterogeneity and could serve as a universal standard.

Watch out: Heterogeneity is very high (I² up to 92%), so any single pooled number is unstable; the reference standard is classification criteria that partly incorporate gland tests, which can inflate apparent accuracy.

Source: Zhou M et al.. Diagnostic accuracy of salivary gland ultrasonography with different scoring systems in Sjögren's syndrome: a systematic review and meta-analysis. Scientific reports. 2018. PMID: 30459471. Registry ID: not stated in the record. MeSH: Consensus · Databases, Factual · Humans · Odds Ratio · Salivary Glands/pathology · Sensitivity and Specificity · Severity of Illness Index · Sjogren's Syndrome/diagnosis,pathology · Ultrasonography/methods

Card 2 — Cornec 2013: in 158 patients with suspected primary Sjögren's, the best single-gland ultrasound grade (cut-off ≥2) gave sensitivity 62.8% and specificity 95.0%; adding ultrasound to a weighted score reached sensitivity 85.7% and specificity 94.9%

Study: Primary diagnostic accuracy study

Population: 158 patients in a prospective cohort (2006–2011) with suspected primary Sjögren's syndrome, in whom bilateral parotid and submandibular echostructure was graded 0–4, gland size measured and parotid Doppler assessed; the reference standard was expert clinical diagnosis blinded to ultrasound, and 78 patients were diagnosed with primary Sjögren's (61 of them meeting American-European Consensus Group criteria).

Summary: Cornec 2013: in 158 patients with suspected primary Sjögren's, the best single-gland ultrasound grade (cut-off ≥2) gave sensitivity 62.8% and specificity 95.0%; adding ultrasound to a weighted score reached sensitivity 85.7% and specificity 94.9%

Result: Sensitivity (in words: the share of true cases flagged) and specificity (in words: the share of non-cases cleared) are labelled here at first use in this card: the highest grade among the 4 glands gave the best diagnostic value, with an optimal cut-off of grade 2 giving sensitivity 62.8% and specificity 95.0%. Doppler waveform analysis and gland size performed poorly. A weighted score combining salivary flow, Schirmer's test, biopsy, SSA/SSB antibodies and ultrasound (score ≥5 of 12.5) reached sensitivity 85.7% and specificity 94.9%.

Watch out: Single-centre cohort of suspected cases; the weighted score was derived and tested in the same patients, so its accuracy is optimistic until externally validated.

Source: Cornec D et al.. Contribution of salivary gland ultrasonography to the diagnosis of Sjögren's syndrome: toward new diagnostic criteria? Arthritis and rheumatism. 2013. PMID: 23108632. Registry ID: not stated in the record. MeSH: Adult · Aged · Cross-Sectional Studies · Female · Humans · Male · Middle Aged · Salivary Glands/diagnostic imaging · Sensitivity and Specificity · Sjogren's Syndrome/diagnostic imaging · Ultrasonography

Card 3 — Song & Lee 2014 meta-analysis: salivary ultrasound pooled sensitivity 77.4% and specificity 81.5% — comparable overall accuracy to sialography (sensitivity 80.0%, specificity 89.0%), with ultrasound's area under the curve 0.864 versus 0.824

Study: Systematic review and meta-analysis of diagnostic accuracy studies

Population: Meta-analysis of six studies (488 patients and 447 controls, two European and four Asian) comparing the diagnostic performance of sialography and salivary ultrasonography in Sjögren's syndrome patients.

Summary: Song & Lee 2014 meta-analysis: salivary ultrasound pooled sensitivity 77.4% and specificity 81.5% — comparable overall accuracy to sialography (sensitivity 80.0%, specificity 89.0%), with ultrasound's area under the curve 0.864 versus 0.824

Result: For sialography, pooled sensitivity (in words: the share of true cases flagged) was 80.0% (95% CI 76.4–83.2) and specificity (in words: the share of non-cases cleared) 89.0% (85.8–91.8); for ultrasound, sensitivity was 77.4% (73.7–80.9) and specificity 81.5% (77.6–85.0). Areas under the curve were 0.824 for sialography and 0.864 for ultrasound, leading the authors to conclude ultrasound's diagnostic accuracy is comparable to sialography — without sialography's contrast injection and radiation.

Watch out: Only six studies, and case-control designs (patients versus controls) tend to overstate accuracy compared with consecutive suspected-case cohorts such as Cornec 2013.

Source: Song GG et al.. Diagnostic accuracies of sialography and salivary ultrasonography in Sjögren's syndrome patients: a meta-analysis. Clinical and experimental rheumatology. 2014. PMID: 25005026. Registry ID: not stated in the record. MeSH: Area Under Curve · Humans · Predictive Value of Tests · Prognosis · ROC Curve · Reproducibility of Results · Salivary Glands/diagnostic imaging · Sialography · Sjogren's Syndrome/diagnosis,diagnostic imaging · Ultrasonography