SourceMed · Shelf #10891 in the ask interface

The pictorial blood loss assessment chart (PBAC) only partly measures menstrual blood loss: at the score-100 threshold the original validation found sensitivity and specificity (each labelled in words) above 80%, but across later studies sensitivity ranged 58–99% and specificity 7.5–89%

Shelf #10891 · Women’s health

MEASUREMENT ACCURACY — PARTIAL

Stamped: 2026-11-28.

Evidence published: 1990–2018.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In women being assessed for heavy menstrual bleeding, how accurately do pictorial blood-loss charts and other self-report methods measure true menstrual blood loss against the alkaline hematin reference method — what sensitivity and specificity (each labelled in words) does a pictorial chart score of 100 or more achieve, and how wide is the spread across validation studies?

Balance of the evidence

MEASUREMENT ACCURACY — PARTIAL — The original 1990 validation (28 women, 55 self-scored cycles) found a chart score of 100 or more had sensitivity and specificity (each labelled in words in the cards) above 80% against measured loss. The 2018 systematic review of 71 studies shows how unstable that is in other hands: pictorial chart sensitivity ranged 58–99% and specificity 7.5–89% across studies, and women's own complaint of heavy bleeding performed at 74% / 74%. Pictorial methods remain the most comprehensively validated self-report option, but a chart score is an estimate, not a measurement. MEASUREMENT ACCURACY — PARTIAL.

MeSH: Adult · Diagnostic Techniques, Obstetrical and Gynecological · Female · Hemin/analysis · Humans · Menorrhagia/diagnosis,physiopathology · Middle Aged · Sensitivity and Specificity · Surveys and Questionnaires

Cards (2)

Card 1 — Higham 1990: a pictorial chart score of 100 or more identified menorrhagia with sensitivity and specificity both greater than 80% against objectively measured blood loss

Study: Primary diagnostic accuracy study

Population: 28 women who used the pictorial blood loss assessment chart over 55 menstrual cycles, plus 122 cycle collections scored by a single observer; chart scores (degree of soiling of each sanitary item, plus number of pads or tampons used) were compared with objective menstrual blood loss measurements in mL.

Summary: Higham 1990: a pictorial chart score of 100 or more identified menorrhagia with sensitivity and specificity both greater than 80% against objectively measured blood loss

Result: A pictorial chart score of 100 or more, used as a diagnostic test for menorrhagia, had a specificity (in words: the share of women without objectively heavy loss whom the chart correctly cleared) and a sensitivity (in words: the share of women with objectively heavy loss whom the chart correctly flagged) of greater than 80% each. The authors present the chart as a simple, cheap and reasonably accurate method of assessing blood loss before embarking on treatment.

Watch out: A small derivation study (28 women) from the chart's own developers; later independent validations (next card) found much wider and often worse performance, so the >80% figures are a best case.

Source: Higham JM et al.. Assessment of menstrual blood loss using a pictorial chart. British journal of obstetrics and gynaecology. 1990. PMID: 2400752. Registry ID: not stated in the record. MeSH: Adult · Documentation · Female · Humans · Menorrhagia/diagnosis · Menstrual Hygiene Products · Middle Aged · Patient Participation · Predictive Value of Tests

Card 2 — Magnay 2018 systematic review (71 studies): pictorial chart sensitivity ranged 58–99% and specificity 7.5–89% against reference methods; the menstrual pictogram did better (82–96% / 88–94%) and a simple complaint of heavy bleeding scored 74% / 74%

Study: Systematic review of measurement methods

Population: Systematic review of 71 studies of methods developed or validated to measure menstrual blood loss in women with self-perceived or actual heavy menstrual bleeding or fibroids (including studies with normal-loss controls); 16 studies reported sensitivity and/or specificity for diagnosing heavy menstrual bleeding, 13 of them against the gold-standard alkaline hematin technique.

Summary: Magnay 2018 systematic review (71 studies): pictorial chart sensitivity ranged 58–99% and specificity 7.5–89% against reference methods; the menstrual pictogram did better (82–96% / 88–94%) and a simple complaint of heavy bleeding scored 74% / 74%

Result: Sensitivity (in words: the share of truly heavy losses flagged) and specificity (in words: the share of non-heavy losses cleared) by method were: menstrual-fluid-loss model 89% / 98%; pictorial blood loss assessment chart 58–99% / 7.5–89%; menstrual pictogram 82–96% / 88–94%; models and questionnaires 59–87% / 62–86%; and the woman's own complaint of heavy menstrual bleeding 74% / 74%. Pictorial methods were the most comprehensively validated; every method assessed had limitations.

Watch out: The ranges span different populations, thresholds and reference standards, so they describe inconsistency across settings rather than one chart's performance in one clinic; several included methods were validated by their own developers.

Source: Magnay JL et al.. A systematic review of methods to measure menstrual blood loss. BMC women's health. 2018. PMID: 30134884. Registry ID: not stated in the record. MeSH: Adult · Diagnostic Techniques, Obstetrical and Gynecological · Female · Hemin/analysis · Humans · Menorrhagia/diagnosis,physiopathology · Middle Aged · Sensitivity and Specificity · Surveys and Questionnaires