SourceMed · Shelf #10917 in the ask interface
Low-dose CT screening cuts lung cancer deaths: NLST found a 20.0% relative reduction versus chest radiography, and NELSON a rate ratio of 0.76 in men versus no screening at 10 years
Shelf #10917 · Cancer
LIKELY
Stamped: 2026-11-28.
Evidence published: 2011–2020.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In people at high risk of lung cancer because of smoking, does screening with low-dose computed tomography, compared with chest radiography or no screening, reduce mortality from lung cancer?
Balance of the evidence
LIKELY — Composition: two large randomised screening trials (NLST, 53,454 participants; NELSON, 15,789 participants; total documented evidence base 69,243). NLST: three annual low-dose CT screens versus chest radiography gave lung cancer mortality of 247 versus 309 deaths per 100,000 person-years — a 20.0% relative reduction (95% CI, 6.8–26.7; P=0.004) — and all-cause mortality 6.7% lower in relative terms, at the cost of a 24.2% positive-test rate of which 96.4% were false positives. NELSON: volume CT screening versus no screening gave a 10-year cumulative rate ratio for lung cancer death of 0.76 in men (95% CI, 0.61–0.94; P=0.01), with a referral rate for suspicious nodules of only 2.1%. LIKELY: low-dose CT screening reduces lung cancer mortality in high-risk smokers.
MeSH: Aged · Bias · Female · Humans · Incidence · Lung Neoplasms/diagnostic imaging,mortality,prevention & control · Male · Middle Aged · Patient Compliance · Radiography, Thoracic · Tomography, X-Ray Computed/adverse effects,methods
Cards (3)
Card 1 — NLST (Aberle 2011): lung cancer deaths 247 versus 309 per 100,000 person-years — a 20.0% relative reduction with three annual low-dose CT screens versus chest radiography
Study: Randomised controlled trial
Population: 53,454 people at high risk for lung cancer at 33 US centres, randomised to three annual screenings with low-dose CT (26,722) or single-view chest radiography (26,732); adherence above 90%; data through December 31, 2009.
Summary: NLST (Aberle 2011): lung cancer deaths 247 versus 309 per 100,000 person-years — a 20.0% relative reduction with three annual low-dose CT screens versus chest radiography
Result: Lung cancer incidence was 645 cases per 100,000 person-years on low-dose CT versus 572 on radiography (rate ratio 1.13; 95% CI, 1.03–1.23), while lung cancer mortality was 247 versus 309 per 100,000 person-years — a 20.0% relative reduction (95% CI, 6.8–26.7; P=0.004). All-cause mortality was 6.7% lower in relative terms (P=0.02). Positive tests were 24.2% with low-dose CT versus 6.9% with radiography across the three rounds, and 96.4% of positive low-dose CT results were false positives.
Watch out: The comparator is chest radiography, not no screening, so NLST alone cannot separate the CT effect from any radiography effect; the false-positive burden (96.4% of positives) is the standing price of the benefit.
Source: Aberle DR et al.. Reduced lung-cancer mortality with low-dose computed tomographic screening. The New England journal of medicine. 2011. PMID: 21714641. Registry ID: ClinicalTrials.gov NCT00047385. MeSH: Aged · Bias · Female · Humans · Incidence · Lung Neoplasms/diagnostic imaging,mortality,prevention & control · Male · Middle Aged · Patient Compliance · Radiography, Thoracic · Tomography, X-Ray Computed/adverse effects,methods
Card 2 — NELSON (de Koning 2020): volume CT screening versus no screening — 10-year rate ratio for lung cancer death 0.76 in men (2.50 versus 3.30 deaths per 1,000 person-years)
Study: Randomised controlled trial
Population: 15,789 people aged 50–74 in the Netherlands and Belgium (13,195 men in the primary analysis; 2,594 women) randomised to CT screening at baseline, year 1, year 3 and year 5.5, or no screening; average adherence 90.0%; minimum 10 years of follow-up.
Summary: NELSON (de Koning 2020): volume CT screening versus no screening — 10-year rate ratio for lung cancer death 0.76 in men (2.50 versus 3.30 deaths per 1,000 person-years)
Result: Among men, lung cancer incidence was 5.58 cases per 1,000 person-years in the screening group versus 4.91 in controls, and lung cancer mortality was 2.50 versus 3.30 deaths per 1,000 person-years (cumulative rate ratio at 10 years 0.76; 95% CI, 0.61–0.94; P=0.01) — a 24% relative reduction. Among women the rate ratio was 0.67 (95% CI, 0.38–1.14). Only 2.1% of screened participants were referred for suspicious nodules, and 9.2% had at least one additional scan for an indeterminate result.
Watch out: The primary analysis is in men; the women's subgroup (2,594 participants) is underpowered, with a confidence interval crossing 1 at 10 years despite lower point estimates in years 7–9.
Source: de Koning HJ et al.. Reduced Lung-Cancer Mortality with Volume CT Screening in a Randomized Trial. The New England journal of medicine. 2020. PMID: 31995683. Registry ID: Netherlands Trial Register NL580. MeSH: Aged · Belgium/epidemiology · Cone-Beam Computed Tomography · Early Detection of Cancer/methods · False Positive Reactions · Female · Humans · Incidence · Lung Neoplasms/diagnostic imaging,epidemiology,mortality · Male · Medical Overuse · Middle Aged · Netherlands/epidemiology · Registries · Sex Factors · Smoking/epidemiology
Card 3 — Synthesis: two trials, two comparators, the same mortality answer — LIKELY
Study: Synthesis
Population: Two randomised trials, 69,243 participants.
Summary: Synthesis: two trials, two comparators, the same mortality answer — LIKELY
Result: Low-dose CT screening reduced lung cancer mortality by about a fifth to a quarter in relative terms in both trials; the trials differ mainly in how much false-positive work-up the protocol generates. LIKELY.
Watch out: Eligibility in both trials was defined by heavy smoking histories; who exactly should be offered screening today is the separate eligibility question homed at live shelf #5694.
Source: Synthesis of the reports carded above; no additional source.