SourceMed · Shelf #10939 in the ask interface
Imaging finds gout imperfectly: dual-energy CT pooled sensitivity (in words: the share of gout cases it detects) 0.89 and specificity (in words: the share of non-gout it correctly clears) 0.91, while the ultrasound double contour sign detects less (sensitivity 0.70) but clears more (specificity 0.95)
Shelf #10939 · Bones & joints
MEASUREMENT ACCURACY — PARTIAL
Stamped: 2026-11-28.
Evidence published: 2018–2022.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In patients with suspected gout, how accurately do dual-energy CT (DECT) and musculoskeletal ultrasound signs (double contour sign, tophus, snowstorm sign) diagnose gout against monosodium urate crystal identification in aspirated fluid or tophi — what are their pooled sensitivity and specificity (each labelled in words), and how does disease duration change them?
Balance of the evidence
MEASUREMENT ACCURACY — PARTIAL — Composition: three meta-analyses (28 studies; 7 studies; 13 studies) against crystal identification as the reference standard. The largest pools DECT at sensitivity (in words: the share of gout cases detected) 0.89 and specificity (in words: the share of non-gout correctly cleared) 0.91, the ultrasound double contour sign at sensitivity (in words: the share detected) 0.70 and specificity (in words: the share cleared) 0.95, tophus at sensitivity (in words: the share detected) 0.57 and specificity (in words: the share cleared) 0.99, and all ultrasound signs together at sensitivity (in words: the share detected) 0.84 and specificity (in words: the share cleared) 0.84; a second DECT meta-analysis pools sensitivity (in words: the share detected) 88% and specificity (in words: the share cleared) 90%, and the ultrasound meta-analysis pools the double contour sign at sensitivity (in words: the share detected) 66% and specificity (in words: the share cleared) 92% per person. In early disease (2 years or less), DECT sensitivity (in words: the share detected) falls to 0.75 in the largest analysis. MEASUREMENT ACCURACY — PARTIAL: imaging supports gout when positive but misses a substantial minority, especially early — a negative scan does not exclude gout.
MeSH: Diagnostic Tests, Routine · Gout/diagnostic imaging · Humans · Sensitivity and Specificity · Tomography, X-Ray Computed · Ultrasonography
Cards (4)
Card 1 — Shang 2022 meta-analysis (28 studies): DECT pooled sensitivity 0.89 and specificity 0.91 for gout; ultrasound double contour sign sensitivity 0.70 and specificity 0.95; tophus sensitivity 0.57 and specificity 0.99
Study: Systematic review and meta-analysis of diagnostic accuracy studies
Population: 28 studies evaluating dual-energy CT or ultrasound for the diagnosis of gout, from PubMed, EMBASE, Cochrane and Web of Science, with quality assessed by QUADAS-2; two ultrasound features (double contour sign and tophus) were assessed separately and in combination, with a subgroup for early disease (duration 2 years or less).
Summary: Shang 2022 meta-analysis (28 studies): DECT pooled sensitivity 0.89 and specificity 0.91 for gout; ultrasound double contour sign sensitivity 0.70 and specificity 0.95; tophus sensitivity 0.57 and specificity 0.99
Result: Pooled sensitivity (in words: the share of gout cases detected) and specificity (in words: the share of non-gout correctly cleared) were: DECT 0.89 and 0.91; double contour sign 0.70 and 0.95; tophus 0.57 and 0.99; and all ultrasound signs considered together 0.84 and 0.84. At disease duration of 2 years or less, DECT pooled at sensitivity (in words: the share detected) 0.75 and specificity (in words: the share cleared) 0.85, while combined ultrasound signs pooled at sensitivity (in words: the share detected) 0.93 and specificity (in words: the share cleared) 0.80. The authors conclude DECT has the better overall diagnostic ability except in early disease.
Watch out: The three meta-analyses in this pack draw on overlapping primary studies and must not be read as three independent confirmations; reference standards and case mixes (established versus early gout) differ between studies, which is why the early-disease subgroup prints separately.
Source: Shang J et al.. Diagnostic Performance of Dual-energy CT Versus Ultrasonography in Gout: A Meta-analysis. Academic radiology. 2022. PMID: 32980243. Registry ID: none in the record. MeSH: Diagnostic Tests, Routine · Gout/diagnostic imaging · Humans · Sensitivity and Specificity · Tomography, X-Ray Computed · Ultrasonography
Card 2 — Yu 2018 meta-analysis (7 studies): DECT pooled sensitivity 88% and specificity 90% for gout, with area under the summary ROC curve 0.96
Study: Systematic review and meta-analysis of diagnostic accuracy studies
Population: 7 clinical studies of dual-energy CT for diagnosing gout, from Medline, Embase, PubMed and Cochrane, with bias assessed by QUADAS-2; the reference standards were synovial-fluid crystal assessment or validated criteria as used in the primary studies.
Summary: Yu 2018 meta-analysis (7 studies): DECT pooled sensitivity 88% and specificity 90% for gout, with area under the summary ROC curve 0.96
Result: Pooled sensitivity (in words: the share of gout cases detected) was 88% (95% CI 84% to 90%) and pooled specificity (in words: the share of non-gout correctly cleared) was 90% (95% CI 85% to 93%); the positive likelihood ratio was 8.48 and the negative likelihood ratio 0.10 (both relative measures), and the area under the summary receiver operating characteristic curve was 0.9565. The included studies showed high homogeneity.
Watch out: Only 7 studies, and the authors note clinicians' tendency to substitute DECT for aspiration runs ahead of standardisation; accuracy in established, crystal-proven clinic populations may exceed accuracy in undifferentiated acute arthritis.
Source: Yu Z et al.. Diagnostic accuracy of dual-energy CT in gout: a systematic review and meta-analysis. Skeletal radiology. 2018. PMID: 29725712. Registry ID: none in the record. MeSH: Gout/diagnostic imaging · Humans · Tomography, X-Ray Computed/methods
Card 3 — Zhang 2018 meta-analysis (13 studies): per person, the ultrasound double contour sign pooled at sensitivity 66% and specificity 92%, tophus at 56% and 94%, snowstorm sign at 31% and 91%, and all signs together at 80% and 83%
Study: Systematic review and meta-analysis of diagnostic accuracy studies
Population: 13 studies of musculoskeletal ultrasound for gout against demonstration of monosodium urate crystals in joint fluid or tophi as the reference standard, from Cochrane Library, PubMed/Medline and Embase; three signs (double contour sign, tophus, snowstorm sign) were pooled separately and simultaneously, per person and per joint.
Summary: Zhang 2018 meta-analysis (13 studies): per person, the ultrasound double contour sign pooled at sensitivity 66% and specificity 92%, tophus at 56% and 94%, snowstorm sign at 31% and 91%, and all signs together at 80% and 83%
Result: For person-based evaluation, pooled sensitivity (in words: the share of gout cases detected) and specificity (in words: the share of non-gout correctly cleared) were: double contour sign 66% and 92%; tophus 56% and 94%; snowstorm sign 31% and 91%; and all features considered simultaneously 80% and 83%. Per joint, the double contour sign's specificity (in words: the share cleared) fell to 65% while its sensitivity (in words: the share detected) rose to 75%. The authors conclude ultrasound signs are relatively specific but only modestly sensitive individually.
Watch out: Person-based and joint-based pools answer different questions and print separately here; a per-joint double contour sign with specificity (in words: the share of non-gout joints cleared) of only 65% should not be quoted as the test's headline specificity.
Source: Zhang Q et al.. The diagnostic performance of musculoskeletal ultrasound in gout: A systematic review and meta-analysis. PloS one. 2018. PMID: 29979706. Registry ID: none in the record. MeSH: Gout/diagnosis · Humans · ROC Curve · Reproducibility of Results · Ultrasonography/methods
Card 4 — Synthesis
Study: Synthesis
Population: Three meta-analyses (28, 7 and 13 studies) with overlapping primary-study sets, all against crystal identification or validated criteria.
Summary: Synthesis
Result: DECT detects about 88–89% of gout and clears about 90–91% of non-gout; individual ultrasound signs are more specific than sensitive, and combining signs trades specificity for sensitivity; early disease lowers DECT sensitivity (in words: the share detected) to about 0.75. MEASUREMENT ACCURACY — PARTIAL.
Watch out: PARTIAL because no modality reaches the sensitivity needed to exclude gout when negative, early disease is measurably worse, and the three syntheses share primary studies.
Source: Synthesis of the reports carded above; no additional source.