SourceMed · Shelf #10965 in the ask interface

Plasma iron turnover misleads as a measure of erythropoiesis: ferrokinetic evaluation in 10 healthy subjects and 51 patients found marrow iron turnover the realistic index, with iron stores and marrow activity setting tissue iron exchange

Shelf #10965 · Cancer

PHYSIOLOGY — EMERGING

Stamped: 2026-11-28.

Evidence published: 1977–1986.

Last source check: not yet re-checked since stamping.

Source correction status: not yet checked for source corrections.

Question

In humans, what do ferrokinetic measurements — plasma iron clearance, plasma iron turnover, red-cell iron utilisation and marrow iron turnover after labelled iron — actually measure about erythropoiesis, and what determines the exchange of iron between plasma and tissues?

Balance of the evidence

PHYSIOLOGY — EMERGING — Composition: two ferrokinetic evaluation studies from one research group (10 healthy subjects with 51 haematology patients; and 14 healthy subjects with 39 patients across iron deficiency, haemochromatosis and haemolysis — 114 documented subjects) plus one labelled-iron study in uraemia and dialysis patients whose group sizes are not stated in its abstract. The evaluation is a caution inside the physiology: the plasma iron clearance half-time does not reflect erythroid activity, plasma iron turnover can mislead particularly when marrow activity is reduced, and red-cell utilisation gives a distorted picture of effective erythropoiesis except in erythroid hypoplasia — marrow iron turnover and red-cell iron turnover are the more realistic measures. Tissue iron exchange itself is set mainly by two factors: the level of iron stores and the marrow's erythropoietic activity. In uraemia the standard ferrokinetic indices all read 'normal' despite anaemia, indicating erythropoietic activity inadequate for the degree of anaemia. PHYSIOLOGY — EMERGING: ferrokinetics measures iron exchange faithfully only at the marrow level; its plasma-level shortcuts do not measure erythropoiesis.

MeSH: Bone Marrow/metabolism · Cell Survival · Erythrocytes/metabolism · Erythropoiesis · Half-Life · Hematologic Diseases/physiopathology · Humans · Iron/blood,metabolism

Cards (4)

Card 1 — Ricketts 1977: in 10 healthy subjects and 51 patients, the plasma iron clearance half-time did not reflect erythroid activity and plasma iron turnover misled when marrow activity was reduced

Study: Primary physiological study

Population: 10 normal subjects and 51 patients with uncomplicated haematological disorders, in whom the standard ferrokinetic measurements were compared against total marrow iron turnover and red-cell iron turnover measured by the group's reference method.

Summary: Ricketts 1977: in 10 healthy subjects and 51 patients, the plasma iron clearance half-time did not reflect erythroid activity and plasma iron turnover misled when marrow activity was reduced

Result: The plasma iron clearance half-time does not reflect erythroid activity, and plasma iron turnover can be particularly misleading in patients with reduced marrow activity. Red-cell utilisation of labelled iron and erythrocyte iron turnover calculated from it give a distorted reflection of effective erythropoiesis except in patients with erythroid hypoplasia. Marrow iron turnover and red-cell iron turnover provide more realistic and generally applicable assessments of both the degree and the effectiveness of erythroid activity.

Watch out: The abstract reports the evaluation's conclusions without printing the underlying numeric turnover values, so this card is qualitative on magnitude — flagged here and in the summary; the healthy group is 10 subjects.

Source: Ricketts C et al.. Ferrokinetics and erythropoiesis in man: an evaluation of ferrokinetic measurements. British journal of haematology. 1977. PMID: 869994. Registry ID: none in the record. MeSH: Bone Marrow/metabolism · Cell Survival · Erythrocytes/metabolism · Erythropoiesis · Half-Life · Hematologic Diseases/physiopathology · Humans · Iron/blood,metabolism

Card 2 — Cavill 1979: across 14 healthy subjects and 39 patients, the two main determinants of tissue iron turnover were the level of iron stores and marrow erythropoietic activity

Study: Primary physiological study

Population: 53 subjects in total: 14 normal subjects, 17 iron-deficient patients, 9 patients with primary idiopathic haemochromatosis and 13 patients with haemolytic disorders, in whom exchange of iron between plasma and erythroid and non-erythroid tissues was measured.

Summary: Cavill 1979: across 14 healthy subjects and 39 patients, the two main determinants of tissue iron turnover were the level of iron stores and marrow erythropoietic activity

Result: The exchange of iron between plasma and erythroid and non-erythroid tissues was measured in all four groups, and the two main factors determining tissue iron turnover were shown to be the level of iron stores and the erythropoietic activity of the bone marrow.

Watch out: Like its companion paper, the abstract states the determinants without printing absolute turnover rates; carded for the determinant finding, with the healthy anchor at 14 subjects.

Source: Cavill I et al.. Erythropoiesis, iron stores and tissue iron exchange in man. Clinical science (London, England : 1979). 1979. PMID: 477205. Registry ID: none in the record. MeSH: Adult · Anemia, Hypochromic/metabolism · Erythropoiesis · Hematologic Diseases/metabolism · Hemochromatosis/metabolism · Hemolysis · Humans · Iron/metabolism · Reference Values

Card 3 — Lee 1986: in uraemia and CAPD, every standard ferrokinetic index read 'normal' despite anaemia — plasma iron turnover, red-cell utilisation and marrow transit time alike

Study: Primary physiological study

Population: Patients with uraemia not yet on dialysis, patients on continuous ambulatory peritoneal dialysis (CAPD) with persistently low or with improved haematocrit, and patients with iron-deficiency anaemia and normal renal function, studied with 59Fe-citrate; the abstract does not state the group sizes, and that is stated here rather than estimated.

Summary: Lee 1986: in uraemia and CAPD, every standard ferrokinetic index read 'normal' despite anaemia — plasma iron turnover, red-cell utilisation and marrow transit time alike

Result: Plasma iron disappearance rate, plasma iron turnover rate, red-cell iron utilisation, red-cell iron turnover rate and marrow transit time were all 'normal' in the uraemic and CAPD groups (haematocrits 23.8% ± 3.4%, 24.9% ± 1.8% and 32.4% ± 3.1%), whereas the iron-deficiency group (haematocrit 28.0% ± 5.1%) had significantly faster disappearance and transit and higher utilisation and red-cell iron turnover. The authors conclude erythropoietic activity is inadequate for the degree of anaemia in uraemia, and that the haematocrit rise on CAPD reflects plasma volume falling back to normal rather than increased red-cell production.

Watch out: Group sizes are not stated in the record's abstract, so this study adds no number to the pack's documented base; it is carded as the clinical demonstration of the evaluation's point — normal-reading plasma indices coexisting with inadequate erythropoiesis.

Source: Lee HB et al.. Ferrokinetics in patients on CAPD: influence of CAPD on the anemia of uremia. The Korean journal of internal medicine. 1986. PMID: 15759377. Registry ID: none in the record. MeSH: Adolescent · Adult · Aged · Anemia/etiology · Erythropoiesis · Female · Hematocrit · Humans · Iron/metabolism · Male · Middle Aged · Peritoneal Dialysis, Continuous Ambulatory · Plasma Volume · Uremia/blood,complications

Card 4 — Synthesis: ferrokinetics is trustworthy at the marrow, misleading at the plasma — stores and marrow activity set iron exchange

Study: Synthesis

Population: 114 documented subjects across the two evaluation studies (24 healthy subjects and 90 patients), plus one uraemia study whose group sizes are not stated in its abstract.

Summary: Synthesis: ferrokinetics is trustworthy at the marrow, misleading at the plasma — stores and marrow activity set iron exchange

Result: Plasma iron clearance and turnover do not measure erythroid activity and can mislead; marrow and red-cell iron turnover do. Tissue iron exchange is governed by iron stores and marrow erythropoietic activity, and uraemia shows the practical consequence — normal-reading indices with inadequate production. PHYSIOLOGY — EMERGING.

Watch out: The two principal abstracts print conclusions without absolute turnover values, so the pack carries no invented normal range for plasma iron turnover; any number for it would have to come from full text, not from these records.

Source: Synthesis of the reports carded above; no additional source.