SourceMed · Shelf #11154 in the ask interface
Positional therapy for positional obstructive sleep apnoea: the apnoea-hypopnoea index fell about 7.4 events per hour more than with inactive control in the Cochrane pool, and a vibrating Sleep Position Trainer cut it from 18 to 10 per hour in its randomised trial — but CPAP lowers the index more (documented N = 323 participants in the review pool)
Shelf #11154 · Lungs, breathing & sleep
POSSIBLE
Stamped: 2026-11-28.
Evidence published: 2015–2019.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In adults with positional obstructive sleep apnoea, does positional therapy (keeping the sleeper off the supine position) reduce the apnoea-hypopnoea index and sleepiness compared with inactive control, and how does it compare with CPAP?
Balance of the evidence
POSSIBLE — Composition: 1 Cochrane systematic review (2019; 8 studies, 323 participants) and 2 individually carded randomised trials from inside that pool (Laub 2017, 101 patients; Eijsvogel 2015, 55 patients; neither additive). Direction: positional therapy beat inactive control on the index (mean difference -7.38 events per hour, low-certainty evidence) and on sleepiness (mean difference -1.58 Epworth points, moderate-certainty), but CPAP reduced the index more (mean difference 6.4 events per hour in CPAP's favour, low-certainty), with positional therapy used longer per night in the one study that measured adherence. Device naming: the vibrating device tested in both carded trials is the Sleep Position Trainer, named as published; neither abstract names its manufacturer. Scope note: mandibular advancement devices for obstructive sleep apnoea are a separate question, already owned by Shelf #5915, and are not carded here.
MeSH: Continuous Positive Airway Pressure · Humans · Outcome Assessment, Health Care · Quality of Life · Randomized Controlled Trials as Topic · Sleep Apnea, Obstructive / therapy · Supine Position · Female · Male · Middle Aged · Patient Compliance · Polysomnography · Sleep Apnea Syndromes / metabolism · Sleep Apnea Syndromes / physiopathology · Sleep Apnea Syndromes / therapy · Sleep Stages · Time Factors · Treatment Outcome · Vibration / therapeutic use · Equipment Design · Patient Compliance / statistics & numerical data · Play and Playthings · Posture · Prospective Studies · Surveys and Questionnaires · Tennis
Cards (4)
Card 1 — Cochrane review (2019): positional therapy beat inactive control on the apnoea-hypopnoea index (mean difference -7.38 events per hour) and sleepiness, but CPAP reduced the index more (mean difference 6.4 events per hour in CPAP's favour)
Study: Systematic review of randomised trials (8 studies, 323 participants)
Population: Systematic review of randomised controlled trials of positional therapy (lumbar or abdominal binders, semi-rigid backpacks, full-length pillows, a tennis ball attached to the back of nightwear, and electrical sensors with alarms) versus CPAP or versus inactive control (sham or no positional therapy) in people with obstructive sleep apnoea. Eight studies, 323 participants randomised: 72 in the CPAP comparison and 251 in the inactive-control comparison; three studies used supine vibration alarm devices. Searches to September 2018.
Summary: Cochrane review (2019): positional therapy beat inactive control on the apnoea-hypopnoea index (mean difference -7.38 events per hour) and sleepiness, but CPAP reduced the index more (mean difference 6.4 events per hour in CPAP's favour)
Result: Versus inactive control, positional therapy reduced the Apnoea-Hypopnoea Index (mean difference (MD) -7.38 events per hour, 95% CI -10.06 to -4.7; low-certainty evidence) and improved Epworth Sleepiness Scale scores (MD -1.58, 95% CI -2.89 to -0.29; moderate-certainty evidence, two studies). Versus CPAP, CPAP produced a greater reduction in the index (MD 6.4 events per hour, 95% CI 3.00 to 9.79; low-certainty evidence), while subjective adherence was greater with positional therapy in one study (MD 2.5 hours per night, 95% CI 1.41 to 3.59; moderate-certainty evidence) and Epworth scores did not differ between CPAP and positional therapy in two studies. No significant differences were found for quality of life or cognitive function, none of the studies clearly reported adverse effects, and all studies were of short duration.
Watch out: The certainty of evidence was low to moderate throughout, the CPAP comparison rests on only 72 participants in cross-over trials, and no long-term outcome (cardiovascular events, accidents, mortality) is measured anywhere in the pool.
Source: Srijithesh PR, Aghoram R, Goel A, Dhanya J. Positional therapy for obstructive sleep apnoea. Cochrane Database Syst Rev. 2019. PMID: 31041813. Registry ID: not stated in the record. MeSH: Continuous Positive Airway Pressure · Humans · Outcome Assessment, Health Care · Quality of Life · Randomized Controlled Trials as Topic · Sleep Apnea, Obstructive / therapy · Supine Position
Card 2 — Laub 2017: the Sleep Position Trainer cut the total apnoea-hypopnoea index from 18 to 10 per hour at 2 months versus 20 to 18 on no treatment — but half of users had stopped by 6 months
Study: Randomised controlled trial (101 patients)
Population: Open randomised controlled trial: 101 patients with positional sleep apnoea allocated to the Sleep Position Trainer (a vibrational device; n = 52) or a non-treatment control group (n = 49) for 2 months, after which all patients were followed as a cohort using the Trainer for 6 months. Polygraphy at entry and after 2 and 6 months; supine apnoea-hypopnoea index at entry was 35 per hour (SD 18) in the Trainer group and 38 per hour (SD 15) in controls.
Summary: Laub 2017: the Sleep Position Trainer cut the total apnoea-hypopnoea index from 18 to 10 per hour at 2 months versus 20 to 18 on no treatment — but half of users had stopped by 6 months
Result: In a per-protocol analysis, mean total apnoea-hypopnoea index at entry and after 2 months was 18 per hour (SD 10) and 10 per hour (SD 9; P < 0.001) in the Trainer group versus 20 per hour (SD 9) and 18 per hour (SD 10; not significant) in the control group. Mean supine sleep time fell from 47% (SD 22) to 17% (SD 18; P < 0.001) with the Trainer versus 48% (SD 20) to 39% (SD 21; not significant) in controls. The effect was maintained at 6 months and daytime sleepiness improved after 6 months. Compliance during the first 2 months (use over 4 hours per night on all weekdays) was 75.5% (SD 21.2), but the discontinuation rate was 28.8% at 2 months and 49.4% at 6 months.
Watch out: An open trial reported per-protocol, and its own follow-up shows the practical limit of the treatment: about half of users had discontinued the device by 6 months, so the 2-month index improvement applies to those who keep using it.
Source: Laub RR, Tønnesen P, Jennum PJ. A Sleep Position Trainer for positional sleep apnea: a randomized, controlled trial. J Sleep Res. 2017. PMID: 28370716. Registry ID: not stated in the record. MeSH: Female · Humans · Male · Middle Aged · Patient Compliance · Polysomnography · Sleep Apnea Syndromes / metabolism · Sleep Apnea Syndromes / physiopathology · Sleep Apnea Syndromes / therapy · Sleep Stages · Time Factors · Treatment Outcome · Vibration / therapeutic use
Card 3 — Eijsvogel 2015: the Sleep Position Trainer and the tennis ball technique both cut supine sleep to a median of 0% — treatment success (index under 5) in 68.0% versus 42.9%, with better compliance on the Trainer (75.9% versus 42.3%)
Study: Randomised controlled trial (55 patients)
Population: Randomised controlled trial: 55 patients with positional obstructive sleep apnoea syndrome treated with the Sleep Position Trainer (n = 29) or the Tennis Ball Technique (n = 26), with polysomnography, Epworth Sleepiness Scale and the Quebec Sleep Questionnaire at baseline and 1 month, and objectively measured daily compliance. Baseline Epworth scores were under 10 in both groups (patients were not sleepy at entry).
Summary: Eijsvogel 2015: the Sleep Position Trainer and the tennis ball technique both cut supine sleep to a median of 0% — treatment success (index under 5) in 68.0% versus 42.9%, with better compliance on the Trainer (75.9% versus 42.3%)
Result: Both therapies prevented supine sleep to a median of 0% of the night, resulting in treatment success (apnoea-hypopnoea index under 5) in 68.0% of the Sleep Position Trainer patients and 42.9% of the Tennis Ball Technique patients; the authors concluded the two were equally effective in reducing respiratory indices in mild positional apnoea with normal sleepiness scores. Sleep quality (wake after sleep onset, P = 0.001; awakenings, P = 0.006) and Quebec Sleep Questionnaire scores changed in favour of the Trainer, and effective compliance (at least 4 hours per night on at least 5 days per week) was 75.9% for the Trainer versus 42.3% for the tennis ball technique (P = 0.01).
Watch out: A comparison of two active positional methods over 1 month, not of positional therapy against no treatment — and in patients who were not sleepy at baseline, so it cannot speak to sleepiness outcomes.
Source: Eijsvogel MM, Ubbink R, Dekker J et al.. Sleep position trainer versus tennis ball technique in positional obstructive sleep apnea syndrome. J Clin Sleep Med. 2015. PMID: 25515276. Registry ID: not stated in the record. MeSH: Equipment Design · Female · Humans · Male · Middle Aged · Patient Compliance / statistics & numerical data · Play and Playthings · Polysomnography · Posture · Prospective Studies · Quality of Life · Sleep Apnea, Obstructive / therapy · Surveys and Questionnaires · Tennis · Treatment Outcome
Card 4 — Synthesis: positional therapy works on the index and on sleepiness versus doing nothing, is used more than CPAP but lowers the index less, and loses about half its users by 6 months
Study: Synthesis
Population: The carded record: the 2019 Cochrane review (8 studies, 323 participants) and two trials from inside its pool (Laub 2017; Eijsvogel 2015).
Summary: Synthesis: positional therapy works on the index and on sleepiness versus doing nothing, is used more than CPAP but lowers the index less, and loses about half its users by 6 months
Result: Against inactive control the index fell by about 7.4 more events per hour and sleepiness by about 1.6 Epworth points; the vibrating Sleep Position Trainer reproduced that size of index fall in its own trial (18 to 10 per hour) and outperformed the tennis ball technique on compliance (75.9% versus 42.3%). Against CPAP, positional therapy is the weaker treatment on the index (6.4 events per hour in CPAP's favour) with an adherence advantage. The stamp is POSSIBLE because the trials are small and short, the outcomes are surrogates and sleepiness scores, and discontinuation is high.
Watch out: Both carded trials sit inside the Cochrane pool, so the documented total is the pool's 323 participants, not a sum of the three records.
Source: Synthesis of the carded records above (PMIDs 31041813, 28370716, 25515276). Registry ID: not stated in the records.