High-flow nasal oxygen for acute hypoxaemic respiratory failure: intubation did not differ significantly in FLORALI (38% versus 47% on standard oxygen and 50% on noninvasive ventilation) although 90-day mortality favoured high-flow; in immunocompromised patients (HIGH) 28-day mortality was 35.6% versus 36.1% and intubation 38.7% versus 43.8%, neither significant (documented N = 1,086 randomised across two trials)
Shelf #11304 · Critical care & sepsis
SPLIT — POSSIBLE (benefit) on 90-day mortality in FLORALI's general population (a secondary outcome of a single trial) / POSSIBLE (the treatment made no difference) on intubation in FLORALI and on mortality and intubation in immunocompromised patients (HIGH)
Stamped: 2026-11-28.
Evidence published: 2015–2018.
Last source check: not yet re-checked since stamping.
Source correction status: not yet checked for source corrections.
Question
In adults with acute hypoxaemic (non-hypercapnic) respiratory failure, does high-flow oxygen through a nasal cannula reduce intubation or death compared with standard oxygen therapy (or noninvasive ventilation)?
Balance of the evidence
SPLIT, Tier C — Composition: two randomised trials (1,086 patients in total) answering neighbouring slices of the question, and they split. FLORALI (310 patients without hypercapnia, PaO2/FiO2 of 300 mm Hg or less) found no significant difference in its primary outcome, intubation at day 28 (38% high-flow versus 47% standard oxygen versus 50% noninvasive ventilation, P=0.18), but 90-day mortality — a secondary outcome — favoured high-flow oxygen (hazard ratio for death 2.01 for standard oxygen versus high-flow and 2.50 for noninvasive ventilation versus high-flow, both relative measures). HIGH (776 immunocompromised patients) found no significant difference in 28-day mortality (35.6% versus 36.1%) or intubation (38.7% versus 43.8%) against standard oxygen. The split is therefore printed rather than averaged: a mortality signal from one trial's secondary outcome in a general population, and no difference on any hard outcome in the immunocompromised population. Adjacent questions are owned elsewhere and not re-carded: noninvasive ventilation in immunocompromised respiratory failure (#9318), high-flow after extubation (#1309, #3134), home high-flow in hypercapnic COPD (#2799), and the ROX prediction index (#7544). This shelf covers only initial oxygen strategy in acute hypoxaemic failure.
MeSH: Acute Disease · Adult · Aged · Critical Illness / mortality · Critical Illness / therapy · Female · High-Frequency Ventilation* · Humans · Hypoxia / etiology · Immunocompromised Host* · Intubation, Intratracheal / statistics & numerical data · Kaplan-Meier Estimate · Male · Middle Aged · Noninvasive Ventilation · Oxygen / administration & dosage* · Oxygen Inhalation Therapy / instrumentation · Oxygen Inhalation Therapy / methods* · Positive-Pressure Respiration / instrumentation* · Respiratory Insufficiency / complications · Respiratory Insufficiency / mortality · Respiratory Insufficiency / therapy* · Survival Analysis
Cards (3)
Card 1 — FLORALI 2015: intubation 38% on high-flow versus 47% on standard oxygen and 50% on NIV (not significant) — but 90-day mortality favoured high-flow oxygen
Study: Randomised controlled trial (310 patients in the analyses)
Population: Multicentre open-label randomised trial: 310 patients without hypercapnia who had acute hypoxemic respiratory failure with a PaO2/FiO2 ratio of 300 mm Hg or less, assigned to high-flow oxygen through a nasal cannula (106 analysed), standard oxygen through a face mask (94), or noninvasive positive-pressure ventilation (110); the primary outcome was the proportion intubated at day 28.
Summary: FLORALI 2015: intubation 38% on high-flow versus 47% on standard oxygen and 50% on NIV (not significant) — but 90-day mortality favoured high-flow oxygen
Result: Intubation rates were 38% (40 of 106) on high-flow oxygen, 47% (44 of 94) on standard oxygen and 50% (55 of 110) on noninvasive ventilation (P=0.18 for all comparisons) — no significant difference. Ventilator-free days at day 28 were higher on high-flow oxygen (24±8 versus 22±10 and 19±12 days, P=0.02). The hazard ratio for death at 90 days was 2.01 (95% CI 1.01 to 3.99) for standard oxygen versus high-flow oxygen (P=0.046) and 2.50 (1.31 to 4.78) for noninvasive ventilation versus high-flow oxygen (P=0.006) — relative measures from a secondary outcome.
Watch out: The mortality result is a secondary outcome in a 310-patient open-label trial whose primary outcome was null; hazard ratios just clear significance (lower confidence bound 1.01 for the standard-oxygen comparison). It is a signal to weigh, not a settled mortality benefit.
Source: Frat JP et al. High-flow oxygen through nasal cannula in acute hypoxemic respiratory failure. N Engl J Med. 2015. PMID: 25981908. Registry ID: NCT01320384. MeSH: Acute Disease · Adult · Aged · Female · Humans · Hypoxia / etiology · Intubation, Intratracheal / statistics & numerical data · Kaplan-Meier Estimate · Male · Middle Aged · Oxygen / administration & dosage* · Oxygen Inhalation Therapy / instrumentation · Oxygen Inhalation Therapy / methods* · Positive-Pressure Respiration / instrumentation* · Respiratory Insufficiency / complications · Respiratory Insufficiency / mortality · Respiratory Insufficiency / therapy*
Card 2 — HIGH 2018: in immunocompromised patients, high-flow oxygen did not reduce 28-day mortality (35.6% versus 36.1%) or intubation (38.7% versus 43.8%) versus standard oxygen
Study: Randomised controlled trial (776 patients completing the trial of 778 randomised)
Population: Randomised trial at 32 intensive care units in France: 776 immunocompromised adults with acute respiratory failure (PaO2 below 60 mm Hg or SpO2 below 90% on room air, or tachypnoea or respiratory distress, needing at least 6 litres per minute of oxygen), assigned to continuous high-flow oxygen therapy (388) or standard oxygen therapy (388); the primary outcome was day-28 mortality.
Summary: HIGH 2018: in immunocompromised patients, high-flow oxygen did not reduce 28-day mortality (35.6% versus 36.1%) or intubation (38.7% versus 43.8%) versus standard oxygen
Result: Day-28 mortality was 35.6% on high-flow oxygen versus 36.1% on standard oxygen (difference −0.5% [95% CI −7.3 to +6.3]; hazard ratio 0.98 [0.77 to 1.24], P=0.94) — no significant difference. Intubation was 38.7% versus 43.8% (difference −5.1% [−12.3 to +2.0]), also not significant. High-flow patients had a higher PaO2:FIO2 ratio (150 versus 119) and lower respiratory rate after 6 hours, with no significant differences in intensive-care or hospital stay, ICU-acquired infections, comfort or dyspnoea.
Watch out: The immunocompromised population is the one in which early noninvasive strategies were most hoped to help; this trial's null result on both hard outcomes is the strongest single check on generalising FLORALI's mortality signal.
Source: Azoulay E et al. Effect of High-Flow Nasal Oxygen vs Standard Oxygen on 28-Day Mortality in Immunocompromised Patients With Acute Respiratory Failure: The HIGH Randomized Clinical Trial. JAMA. 2018. PMID: 30357270. Registry ID: NCT02739451. MeSH: Adult · Aged · Critical Illness / mortality · Critical Illness / therapy · Female · High-Frequency Ventilation* · Humans · Immunocompromised Host* · Male · Middle Aged · Noninvasive Ventilation · Oxygen Inhalation Therapy / instrumentation · Oxygen Inhalation Therapy / methods* · Respiratory Insufficiency / mortality · Respiratory Insufficiency / therapy* · Survival Analysis
Card 3 — Synthesis: SPLIT — high-flow oxygen is at least as good as standard oxygen everywhere it was tested, clearly better on no primary outcome, and better on 90-day mortality in one trial's secondary analysis only
Study: Synthesis
Population: The carded record: FLORALI (310 patients) and HIGH (776 patients); total documented N = 1,086, independent trials in different populations, additive.
Summary: Synthesis: SPLIT — high-flow oxygen is at least as good as standard oxygen everywhere it was tested, clearly better on no primary outcome, and better on 90-day mortality in one trial's secondary analysis only
Result: The honest summary is the split on the stamp: comfort and physiology favour high-flow, intubation is unproven in both trials, and the mortality claim rests on a single secondary outcome contradicted in direction-setting by HIGH's null primary outcome — hence.
Watch out: Hypercapnic failure is excluded from both trials; post-extubation high-flow (#1309, #3134), home high-flow in COPD (#2799) and NIV in immunocompromised patients (#9318) are separate shelves.
Source: Synthesis of the carded records above (PMIDs 25981908, 30357270). Registry IDs: NCT01320384 (FLORALI), NCT02739451 (HIGH).